/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile_fmu --startTime=0 --stopTime=11000 --stepSize=4.4 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile/model-l9zutrl2" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Technologies.ThermalStorages.Examples.FluidStorageChargeDischargeProfile" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: BuildingSystems_BuildingSystems_Technologies_ThermalStorages_Examples_FluidStorageChargeDischargeProfile.fmu - startTime: 0.000000 - stopTime: 11000.000000 - tolerance: 0.000001 - stepSize: 4.400000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Technologies/ThermalStorages/BaseClasses/BuoyancyModels/Buoyancy1.mo:11:3-12:165:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "The number of nodes used nEle is out of the validated range (between 4 and 40), see Info section of the selected buoyancy model." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not senTem_bottom.warnAboutOnePortConnection)) --> "Sensor FluidStorageChargeDischargeProfile.senTem_bottom can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in FluidStorageChargeDischargeProfile.senTem_bottom." info: Result file: model_res.mat (bufferSize=10) info: 2 warnings info: 0 errors