/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate_fmu --startTime=0 --stopTime=86400 --stepSize=34.56 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.SolarCollectors.Validation.FlatPlate" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.SolarCollectors.Validation.FlatPlate" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.SolarCollectors.Validation.FlatPlate/model-n5pjokli" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.SolarCollectors.Validation.FlatPlate" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate.fmu - startTime: 0.000000 - stopTime: 86400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_STDOUT | info | ... loading "TRNSYS" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.SolarCollectors.Validation.FlatPlate/model-n5pjokli/temp/0001_AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Resources/Data/Fluid/SolarCollectors/Validation/FlatPlate/TRNSYSAnnualData.txt" info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate.datRea.delimiter will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate.datRea.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 103.680000 | | | | ((noEvent(solCol.vol[2].dynBal.medium.T <= 403.15))) --> "In FlatPlate.solCol.vol[2].dynBal.medium: Temperature T = 880.69 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate/logFmi2Call: internalEventUpdate: terminated by an assertion. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Media/Water.mo:63:5-64:119:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((noEvent(solCol.vol[1].dynBal.medium.T >= 272.15))) --> "In FlatPlate.solCol.vol[1].dynBal.medium: Temperature T = -222.381 K exceeded its minimum allowed value of -1 degC (272.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Media/Water.mo:66:5-67:119:writable] | | | | The following assertion has been violated at time 138.240000 | | | | ((noEvent(solCol.vol[1].dynBal.medium.T <= 403.15))) --> "In FlatPlate.solCol.vol[1].dynBal.medium: Temperature T = 10469.1 K exceeded its maximum allowed value of 130 degC (403.15 Kelvin) as required from medium model "AixLib.Media.Water"." error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_SolarCollectors_Validation_FlatPlate/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable weaDat.computeWetBulbTemperature error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 6 errors