/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Fluid_Movers_Validation_ControlledFlowMachine_fmu --startTime=0 --stopTime=600 --stepSize=0.24 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Fluid_Movers_Validation_ControlledFlowMachine.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Validation.ControlledFlowMachine" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Validation.ControlledFlowMachine" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Validation.ControlledFlowMachine/model-it0x495v" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Fluid.Movers.Validation.ControlledFlowMachine" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: AixLib_AixLib_Fluid_Movers_Validation_ControlledFlowMachine.fmu - startTime: 0.000000 - stopTime: 600.000000 - tolerance: 0.000001 - stepSize: 0.240000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eta, has value: -2.19301e-30" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan1.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan1.eff.yMot, has value: -2.79208e-32" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan2.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan2.eta, has value: -1.62509e-27" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fan2.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan2.eff.yMot, has value: -2.06902e-29" info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Media/Air.mo:146:5-147:69:writable] | | | | The following assertion has been violated at time 0.720000 | | | | ((noEvent(fan1.vol.dynBal.medium.Xi[1] >= -1e-5) and noEvent(fan1.vol.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = 1.79896 of substance water | | | | of medium "AixLib.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_Movers_Validation_ControlledFlowMachine/logFmi2Call: fmi2CompletedIntegratorStep: terminated by an assertion. error: [stepUntil] fmi2_doStep failed for FMU "model.root.AixLib_AixLib_Fluid_Movers_Validation_ControlledFlowMachine" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Media/Air.mo:146:5-147:69:writable] | | | | The following assertion has been violated at time 0.720000 | | | | ((noEvent(fan1.vol.dynBal.medium.Xi[1] >= -1e-5) and noEvent(fan1.vol.dynBal.medium.Xi[1] <= 1.00001))) --> "Mass fraction X[1] = 1.79896 of substance water | | | | of medium "AixLib.Media.Air" is not in the range 0..1" error: [fmi2logger] [fmi2Error] AixLib_AixLib_Fluid_Movers_Validation_ControlledFlowMachine/logFmi2Call: fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sou.verifyInputs error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 5 errors