/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AES_AES_Coursework_ThermSys_component_models_Heater_power_vs_wTin_heater_wT_fmu --startTime=0 --stopTime=1.5e+06 --stepSize=1500 --timeout=50 --tolerance=1e-06 AES_AES_Coursework_ThermSys_component_models_Heater_power_vs_wTin_heater_wT.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_component_models.Heater_power_vs_wTin.heater_wT" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_component_models.Heater_power_vs_wTin.heater_wT" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_component_models.Heater_power_vs_wTin.heater_wT/model-dt4hgdp5" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AES_AES.Coursework.ThermSys_component_models.Heater_power_vs_wTin.heater_wT" info: *** FMU Simulation Info *** - model: model (co-simulation) - path: AES_AES_Coursework_ThermSys_component_models_Heater_power_vs_wTin_heater_wT.fmu - startTime: 0.000000 - stopTime: 1500000.000000 - tolerance: 0.000001 - stepSize: 1500.000000 LOG_SOLVER | info | CVODE linear multistep method CV_BDF LOG_SOLVER | info | CVODE maximum integration order CV_ITER_NEWTON LOG_SOLVER | info | CVODE use equidistant time grid YES LOG_SOLVER | info | CVODE Using relative error tolerance 1.000000e-06 LOG_SOLVER | info | CVODE Using dense internal linear solver SUNLinSol_Dense. LOG_SOLVER | info | CVODE Use internal dense numeric jacobian method. LOG_SOLVER | info | CVODE uses internal root finding method NO LOG_SOLVER | info | CVODE maximum absolut step size 0 LOG_SOLVER | info | CVODE initial step size is set automatically LOG_SOLVER | info | CVODE maximum integration order 5 LOG_SOLVER | info | CVODE maximum number of nonlinear convergence failures permitted during one step 10 LOG_SOLVER | info | CVODE BDF stability limit detection algorithm OFF info: Result file: model_res.mat (bufferSize=10) error: [getReal] getReal returned +/-inf error: [updateSignals] failed to fetch variable tube.pwh_b.h error: [getReal] getReal returned +/-inf error: [updateSignals] failed to fetch variable tube.pwh_b.h fmi2DoStep: ##CVODE## -4 error occurred at time = 432000.error: [fmi2logger] [fmi2Fatal] AES_AES_Coursework_ThermSys_component_models_Heater_power_vs_wTin_heater_wT/logStatusFatal: fmi2DoStep: CVODE integrator step failed. error: [stepUntil] fmi2_doStep failed for FMU "model.root.AES_AES_Coursework_ThermSys_component_models_Heater_power_vs_wTin_heater_wT" error: [getReal] getReal returned +/-inf error: [updateSignals] failed to fetch variable tube.pwh_b.h error: [SimulateSingleFMU] oms_simulate failed info: 2 warnings info: 9 errors