Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo): time 2.329/2.329, allocations: 396 MB / 416.4 MB, free: 13.93 MB / 318.1 MB " [Timeout remaining time 177] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.000729/0.000729, allocations: 39.81 kB / 0.5037 GB, free: 12.01 MB / 414.1 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) [Timeout 180] "[/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 1.318/1.318, allocations: 128.7 MB / 0.7264 GB, free: 18 MB / 0.4982 GB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo): time 0.1166/0.1166, allocations: 23.17 MB / 0.8731 GB, free: 9.438 MB / 0.6232 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.009426/0.009426, allocations: 0.8904 MB / 1.004 GB, free: 194.5 MB / 0.7325 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.2801/0.2801, allocations: 45.27 MB / 1.179 GB, free: 46.25 MB / 0.7325 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.1038/0.1038, allocations: 13.78 MB / 1.332 GB, free: 219.8 MB / 0.795 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00127/0.00127, allocations: 107.7 kB / 1.475 GB, free: 83.46 MB / 0.795 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001903/0.001903, allocations: 197.3 kB / 1.618 GB, free: 243.1 MB / 0.8419 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.804/1.804, allocations: 225.6 MB / 1.981 GB, free: 92.13 MB / 0.8888 GB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0008671/0.0008671, allocations: 27.95 kB / 2.174 GB, free: 3.914 MB / 0.9357 GB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0007373/0.0007373, allocations: 28.52 kB / 2.368 GB, free: 270.6 MB / 1.108 GB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.188/1.188, allocations: 223.5 MB / 2.78 GB, free: 15.17 MB / 1.201 GB " [Timeout remaining time 177] Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.2 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/package.mo) Running command: translateModel(TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes,tolerance=1e-06,outputFormat="empty",numberOfIntervals=600,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes") translateModel(TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes,tolerance=1e-06,outputFormat="empty",numberOfIntervals=600,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes") [Timeout 660] "Warning: Requested package TILMedia of version 1.8.1 ClaRa, but this package was already loaded with version 1.8.2 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.2 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, \"1.8.1\") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.008302/0.008302, allocations: 323.5 kB / 3.281 GB, free: 204 kB / 1.436 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.477/2.486, allocations: 243 MB / 3.518 GB, free: 43.42 MB / 1.514 GB Notification: Performance of NFInst.instantiate(TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes): time 0.06495/2.551, allocations: 67.09 MB / 3.584 GB, free: 10.94 MB / 1.53 GB Notification: Performance of NFInst.instExpressions: time 0.1022/2.653, allocations: 38.62 MB / 3.622 GB, free: 15.46 MB / 1.561 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.02724/2.68, allocations: 331.7 kB / 3.622 GB, free: 15.36 MB / 1.561 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.0252/2.705, allocations: 7.473 MB / 3.629 GB, free: 11.73 MB / 1.561 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/VLEFluidFunctions.mo:175:13-179:19:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.density_phxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.density_phxi'. Notification: Performance of NFTyping.typeBindings: time 0.04301/2.748, allocations: 11.67 MB / 3.641 GB, free: 5.059 MB / 1.561 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/GasProperties/verboseXi.mo:2:1-93:14:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.verboseXi' contains a call to impure function 'Modelica.Utilities.Streams.print'. Notification: Performance of NFTyping.typeClassSections: time 0.04028/2.789, allocations: 11.94 MB / 3.652 GB, free: 13.22 MB / 1.577 GB Notification: Performance of NFFlatten.flatten: time 0.07891/2.868, allocations: 38.92 MB / 3.69 GB, free: 6.668 MB / 1.592 GB Notification: Performance of NFFlatten.resolveConnections: time 0.02794/2.895, allocations: 12.53 MB / 3.703 GB, free: 12.11 MB / 1.608 GB Notification: Performance of NFEvalConstants.evaluate: time 0.04888/2.944, allocations: 15.15 MB / 3.717 GB, free: 12.91 MB / 1.624 GB Notification: Performance of NFSimplifyModel.simplify: time 0.04709/2.991, allocations: 24.17 MB / 3.741 GB, free: 4.672 MB / 1.639 GB Notification: Performance of NFPackage.collectConstants: time 0.02034/3.012, allocations: 4.492 MB / 3.745 GB, free: 184 kB / 1.639 GB Notification: Performance of NFFlatten.collectFunctions: time 0.03103/3.043, allocations: 5.739 MB / 3.751 GB, free: 10.44 MB / 1.655 GB Notification: Performance of NFScalarize.scalarize: time 0.04168/3.084, allocations: 20.7 MB / 3.771 GB, free: 5.684 MB / 1.67 GB Notification: Performance of NFVerifyModel.verify: time 0.06658/3.151, allocations: 23.04 MB / 3.794 GB, free: 14.53 MB / 1.702 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:79:53-79:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:83:53-83:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:42:70-42:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:71-105:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.1794/3.33, allocations: 93.19 MB / 3.885 GB, free: 1.262 MB / 1.78 GB Notification: Performance of FrontEnd - DAE generated: time 9.067e-06/3.33, allocations: 0 / 3.885 GB, free: 1.262 MB / 1.78 GB Notification: Performance of FrontEnd: time 3.166e-06/3.33, allocations: 0 / 3.885 GB, free: 1.262 MB / 1.78 GB Notification: Performance of Transformations before backend: time 0.002384/3.333, allocations: 3.984 kB / 3.885 GB, free: 1.258 MB / 1.78 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 6597 * Number of variables: 6597 Notification: Performance of Generate backend data structure: time 0.1947/3.528, allocations: 50.64 MB / 3.934 GB, free: 14.3 MB / 1.842 GB Notification: Performance of prepare preOptimizeDAE: time 5.5e-05/3.528, allocations: 16.03 kB / 3.934 GB, free: 14.28 MB / 1.842 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02785/3.556, allocations: 4.417 MB / 3.938 GB, free: 9.84 MB / 1.842 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.1205/3.676, allocations: 43.02 MB / 3.98 GB, free: 14.64 MB / 1.889 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.001845/3.678, allocations: 1.096 MB / 3.982 GB, free: 13.54 MB / 1.889 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01298/3.691, allocations: 1.464 MB / 3.983 GB, free: 12.08 MB / 1.889 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.141/3.832, allocations: 54.07 MB / 4.036 GB, free: 1.938 MB / 1.936 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.00111/3.833, allocations: 134.8 kB / 4.036 GB, free: 1.805 MB / 1.936 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.01272/3.846, allocations: 0.7419 MB / 4.037 GB, free: 1.062 MB / 1.936 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.003964/3.85, allocations: 2.461 MB / 4.039 GB, free: 14.59 MB / 1.952 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.1257/3.975, allocations: 59.4 MB / 4.097 GB, free: 3.09 MB / 1.999 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 2.026/6.001, allocations: 206.7 MB / 4.299 GB, free: 304.2 MB / 2.014 GB Notification: Performance of preOpt comSubExp (simulation): time 0.0502/6.051, allocations: 24.05 MB / 4.322 GB, free: 294.3 MB / 2.014 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.03548/6.087, allocations: 19.76 MB / 4.342 GB, free: 285 MB / 2.014 GB Notification: Performance of preOpt evalFunc (simulation): time 0.1003/6.187, allocations: 40.24 MB / 4.381 GB, free: 257.4 MB / 2.014 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.04365/6.231, allocations: 23.23 MB / 4.404 GB, free: 241.9 MB / 2.014 GB Notification: Performance of pre-optimization done (n=3086): time 4.549e-05/6.231, allocations: 3.031 kB / 4.404 GB, free: 241.9 MB / 2.014 GB Notification: Performance of matching and sorting (n=3086): time 0.1365/6.367, allocations: 67.91 MB / 4.47 GB, free: 174.1 MB / 2.014 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0006212/6.368, allocations: 2.368 MB / 4.472 GB, free: 171.2 MB / 2.014 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.08426/6.452, allocations: 33.79 MB / 4.505 GB, free: 137.8 MB / 2.014 GB Notification: Performance of collectPreVariables (initialization): time 0.006964/6.459, allocations: 289.7 kB / 4.506 GB, free: 137.5 MB / 2.014 GB Notification: Performance of collectInitialEqns (initialization): time 0.02247/6.482, allocations: 16.58 MB / 4.522 GB, free: 122.1 MB / 2.014 GB Notification: Performance of collectInitialBindings (initialization): time 0.02269/6.504, allocations: 10.82 MB / 4.532 GB, free: 112.7 MB / 2.014 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.03688/6.541, allocations: 5.854 MB / 4.538 GB, free: 106.9 MB / 2.014 GB Notification: Performance of setup shared object (initialization): time 7.079e-05/6.541, allocations: 309.1 kB / 4.538 GB, free: 106.6 MB / 2.014 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.03813/6.579, allocations: 21.93 MB / 4.56 GB, free: 84.61 MB / 2.014 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.0454/6.625, allocations: 31.96 MB / 4.591 GB, free: 48.34 MB / 2.014 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.other_demand = $START.pipe4.pipe.collectCosts.other_demand (0.0 = $START.pipe4.pipe.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.other_revenue = $START.pipe4.pipe.collectCosts.other_revenue (0.0 = $START.pipe4.pipe.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.H_demand = $START.pipe4.pipe.collectCosts.H_demand (0.0 = $START.pipe4.pipe.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.H_revenue = $START.pipe4.pipe.collectCosts.H_revenue (0.0 = $START.pipe4.pipe.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.Q_demand = $START.pipe4.pipe.collectCosts.Q_demand (0.0 = $START.pipe4.pipe.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.Q_revenue = $START.pipe4.pipe.collectCosts.Q_revenue (0.0 = $START.pipe4.pipe.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.W_el_demand = $START.pipe4.pipe.collectCosts.W_el_demand (0.0 = $START.pipe4.pipe.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.W_el_revenue = $START.pipe4.pipe.collectCosts.W_el_revenue (0.0 = $START.pipe4.pipe.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.other_demand = $START.pipe3.pipe.collectCosts.other_demand (0.0 = $START.pipe3.pipe.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.other_revenue = $START.pipe3.pipe.collectCosts.other_revenue (0.0 = $START.pipe3.pipe.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.H_demand = $START.pipe3.pipe.collectCosts.H_demand (0.0 = $START.pipe3.pipe.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.H_revenue = $START.pipe3.pipe.collectCosts.H_revenue (0.0 = $START.pipe3.pipe.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.Q_demand = $START.pipe3.pipe.collectCosts.Q_demand (0.0 = $START.pipe3.pipe.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.Q_revenue = $START.pipe3.pipe.collectCosts.Q_revenue (0.0 = $START.pipe3.pipe.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.W_el_demand = $START.pipe3.pipe.collectCosts.W_el_demand (0.0 = $START.pipe3.pipe.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.W_el_revenue = $START.pipe3.pipe.collectCosts.W_el_revenue (0.0 = $START.pipe3.pipe.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand (0.0 = $START.pipe2.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue (0.0 = $START.pipe2.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand (0.0 = $START.pipe2.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue (0.0 = $START.pipe2.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand (0.0 = $START.pipe2.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue (0.0 = $START.pipe2.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand (0.0 = $START.pipe2.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue (0.0 = $START.pipe2.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand (0.0 = $START.pipe1.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue (0.0 = $START.pipe1.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand (0.0 = $START.pipe1.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue (0.0 = $START.pipe1.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand (0.0 = $START.pipe1.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue (0.0 = $START.pipe1.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand (0.0 = $START.pipe1.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue (0.0 = $START.pipe1.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.other_demand = $START.pipe.collectCosts.other_demand (0.0 = $START.pipe.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.other_revenue = $START.pipe.collectCosts.other_revenue (0.0 = $START.pipe.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.H_demand = $START.pipe.collectCosts.H_demand (0.0 = $START.pipe.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.H_revenue = $START.pipe.collectCosts.H_revenue (0.0 = $START.pipe.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.Q_demand = $START.pipe.collectCosts.Q_demand (0.0 = $START.pipe.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.Q_revenue = $START.pipe.collectCosts.Q_revenue (0.0 = $START.pipe.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.W_el_demand = $START.pipe.collectCosts.W_el_demand (0.0 = $START.pipe.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.W_el_revenue = $START.pipe.collectCosts.W_el_revenue (0.0 = $START.pipe.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.m_CDE_consumed = $START.pipe4.pipe.collectCosts.m_CDE_consumed (0.0 = $START.pipe4.pipe.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.m_CDE_produced = $START.pipe4.pipe.collectCosts.m_CDE_produced (0.0 = $START.pipe4.pipe.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.m_CDE_consumed = $START.pipe3.pipe.collectCosts.m_CDE_consumed (0.0 = $START.pipe3.pipe.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.m_CDE_produced = $START.pipe3.pipe.collectCosts.m_CDE_produced (0.0 = $START.pipe3.pipe.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed (0.0 = $START.pipe2.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced (0.0 = $START.pipe2.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed (0.0 = $START.pipe1.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced (0.0 = $START.pipe1.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.m_CDE_consumed = $START.pipe.collectCosts.m_CDE_consumed (0.0 = $START.pipe.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.m_CDE_produced = $START.pipe.collectCosts.m_CDE_produced (0.0 = $START.pipe.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Notification: Performance of analyzeInitialSystem (initialization): time 0.5374/7.162, allocations: 214.7 MB / 4.801 GB, free: 3.219 MB / 2.186 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0006202/7.163, allocations: 88 kB / 4.801 GB, free: 3.133 MB / 2.186 GB Notification: Performance of matching and sorting (n=4583) (initialization): time 0.1515/7.314, allocations: 60.26 MB / 4.86 GB, free: 6.648 MB / 2.249 GB Notification: Performance of prepare postOptimizeDAE: time 0.0006227/7.315, allocations: 137 kB / 4.86 GB, free: 6.516 MB / 2.249 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.00402/7.319, allocations: 0.976 MB / 4.861 GB, free: 5.539 MB / 2.249 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.02298/7.342, allocations: 6.07 MB / 4.867 GB, free: 15.39 MB / 2.264 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.04184/7.384, allocations: 5.666 MB / 4.872 GB, free: 9.711 MB / 2.264 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.06057/7.444, allocations: 54.98 MB / 4.926 GB, free: 15.18 MB / 2.327 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.04278/7.487, allocations: 3.618 MB / 4.929 GB, free: 12.41 MB / 2.327 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01065/7.498, allocations: 1.5 MB / 4.931 GB, free: 10.91 MB / 2.327 GB Warning: Assuming fixed start value for the following 39 variables: pipe4.pipe.h[1]:VARIABLE(start = pipe4.pipe.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe4.pipe.h[2]:VARIABLE(start = pipe4.pipe.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe4.pipe.h[3]:VARIABLE(start = pipe4.pipe.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe4.pipe.p[1]:VARIABLE(min = 0.0 start = pipe4.pipe.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe4.pipe.p[2]:VARIABLE(min = 0.0 start = pipe4.pipe.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe4.pipe.p[3]:VARIABLE(min = 0.0 start = pipe4.pipe.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] realGasCompositionByWtFractions_stepVariation.t_lastchange:VARIABLE(start = 0.0 unit = \"s\" fixed = true ) type: Real pipeFlow_L2_Simple.h[1]:VARIABLE(start = pipeFlow_L2_Simple.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer protected = true ) \"Cell enthalpy\" type: Real [1] pipeFlow_L2_Simple.p[1]:VARIABLE(min = 0.0 start = pipeFlow_L2_Simple.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 protected = true ) \"Cell pressure\" type: Real [1] pipe_L4.h[1]:VARIABLE(start = pipe_L4.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer protected = true ) \"Cell enthalpy\" type: Real [3] pipe_L4.h[2]:VARIABLE(start = pipe_L4.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer protected = true ) \"Cell enthalpy\" type: Real [3] pipe1.h[1]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe1.h[2]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe1.h[3]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe1.p[1]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe1.p[2]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe1.p[3]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] realGasCompositionByWtFractions_stepVariation.xi_in[1]:VARIABLE(min = 0.0 max = 1.0 start = 0.722090178 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] realGasCompositionByWtFractions_stepVariation.xi_in[2]:VARIABLE(min = 0.0 max = 1.0 start = 0.139591715 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] realGasCompositionByWtFractions_stepVariation.xi_in[3]:VARIABLE(min = 0.0 max = 1.0 start = 0.069014479 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] realGasCompositionByWtFractions_stepVariation.xi_in[4]:VARIABLE(min = 0.0 max = 1.0 start = 0.019245659 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] pipe3.pipe.h[1]:VARIABLE(start = pipe3.pipe.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe3.pipe.h[2]:VARIABLE(start = pipe3.pipe.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe3.pipe.h[3]:VARIABLE(start = pipe3.pipe.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe3.pipe.p[1]:VARIABLE(min = 0.0 start = pipe3.pipe.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe3.pipe.p[2]:VARIABLE(min = 0.0 start = pipe3.pipe.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe3.pipe.p[3]:VARIABLE(min = 0.0 start = pipe3.pipe.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe.h[1]:VARIABLE(start = pipe.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe.h[2]:VARIABLE(start = pipe.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe.h[3]:VARIABLE(start = pipe.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe.p[1]:VARIABLE(min = 0.0 start = pipe.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe.p[2]:VARIABLE(min = 0.0 start = pipe.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe.p[3]:VARIABLE(min = 0.0 start = pipe.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe2.h[1]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe2.h[2]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe2.h[3]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe2.p[1]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe2.p[2]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe2.p[3]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] Warning: The initial conditions are over specified. The following 112 initial equations are redundant, so they are removed from the initialization system: pipe4.pipe.collectCosts.other_demand = $START.pipe4.pipe.collectCosts.other_demand pipe4.pipe.collectCosts.other_revenue = $START.pipe4.pipe.collectCosts.other_revenue pipe4.pipe.collectCosts.H_demand = $START.pipe4.pipe.collectCosts.H_demand pipe4.pipe.collectCosts.H_revenue = $START.pipe4.pipe.collectCosts.H_revenue pipe4.pipe.collectCosts.Q_demand = $START.pipe4.pipe.collectCosts.Q_demand pipe4.pipe.collectCosts.Q_revenue = $START.pipe4.pipe.collectCosts.Q_revenue pipe4.pipe.collectCosts.W_el_demand = $START.pipe4.pipe.collectCosts.W_el_demand pipe4.pipe.collectCosts.W_el_revenue = $START.pipe4.pipe.collectCosts.W_el_revenue pipe3.pipe.collectCosts.other_demand = $START.pipe3.pipe.collectCosts.other_demand pipe3.pipe.collectCosts.other_revenue = $START.pipe3.pipe.collectCosts.other_revenue pipe3.pipe.collectCosts.H_demand = $START.pipe3.pipe.collectCosts.H_demand pipe3.pipe.collectCosts.H_revenue = $START.pipe3.pipe.collectCosts.H_revenue pipe3.pipe.collectCosts.Q_demand = $START.pipe3.pipe.collectCosts.Q_demand pipe3.pipe.collectCosts.Q_revenue = $START.pipe3.pipe.collectCosts.Q_revenue pipe3.pipe.collectCosts.W_el_demand = $START.pipe3.pipe.collectCosts.W_el_demand pipe3.pipe.collectCosts.W_el_revenue = $START.pipe3.pipe.collectCosts.W_el_revenue pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue pipe.collectCosts.other_demand = $START.pipe.collectCosts.other_demand pipe.collectCosts.other_revenue = $START.pipe.collectCosts.other_revenue pipe.collectCosts.H_demand = $START.pipe.collectCosts.H_demand pipe.collectCosts.H_revenue = $START.pipe.collectCosts.H_revenue pipe.collectCosts.Q_demand = $START.pipe.collectCosts.Q_demand pipe.collectCosts.Q_revenue = $START.pipe.collectCosts.Q_revenue pipe.collectCosts.W_el_demand = $START.pipe.collectCosts.W_el_demand pipe.collectCosts.W_el_revenue = $START.pipe.collectCosts.W_el_revenue modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] pipe4.pipe.collectCosts.m_CDE_consumed = $START.pipe4.pipe.collectCosts.m_CDE_consumed pipe4.pipe.collectCosts.m_CDE_produced = $START.pipe4.pipe.collectCosts.m_CDE_produced pipe3.pipe.collectCosts.m_CDE_consumed = $START.pipe3.pipe.collectCosts.m_CDE_consumed pipe3.pipe.collectCosts.m_CDE_produced = $START.pipe3.pipe.collectCosts.m_CDE_produced pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced pipe.collectCosts.m_CDE_consumed = $START.pipe.collectCosts.m_CDE_consumed pipe.collectCosts.m_CDE_produced = $START.pipe.collectCosts.m_CDE_produced modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg. Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.08267/7.581, allocations: 32.36 MB / 4.962 GB, free: 10.42 MB / 2.358 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.0632/7.644, allocations: 31.33 MB / 4.993 GB, free: 6.656 MB / 2.389 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.other_demand = $START.pipe4.pipe.collectCosts.other_demand (0.0 = $START.pipe4.pipe.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.other_revenue = $START.pipe4.pipe.collectCosts.other_revenue (0.0 = $START.pipe4.pipe.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.H_demand = $START.pipe4.pipe.collectCosts.H_demand (0.0 = $START.pipe4.pipe.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.H_revenue = $START.pipe4.pipe.collectCosts.H_revenue (0.0 = $START.pipe4.pipe.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.Q_demand = $START.pipe4.pipe.collectCosts.Q_demand (0.0 = $START.pipe4.pipe.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.Q_revenue = $START.pipe4.pipe.collectCosts.Q_revenue (0.0 = $START.pipe4.pipe.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.W_el_demand = $START.pipe4.pipe.collectCosts.W_el_demand (0.0 = $START.pipe4.pipe.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.W_el_revenue = $START.pipe4.pipe.collectCosts.W_el_revenue (0.0 = $START.pipe4.pipe.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.other_demand = $START.pipe3.pipe.collectCosts.other_demand (0.0 = $START.pipe3.pipe.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.other_revenue = $START.pipe3.pipe.collectCosts.other_revenue (0.0 = $START.pipe3.pipe.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.H_demand = $START.pipe3.pipe.collectCosts.H_demand (0.0 = $START.pipe3.pipe.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.H_revenue = $START.pipe3.pipe.collectCosts.H_revenue (0.0 = $START.pipe3.pipe.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.Q_demand = $START.pipe3.pipe.collectCosts.Q_demand (0.0 = $START.pipe3.pipe.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.Q_revenue = $START.pipe3.pipe.collectCosts.Q_revenue (0.0 = $START.pipe3.pipe.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.W_el_demand = $START.pipe3.pipe.collectCosts.W_el_demand (0.0 = $START.pipe3.pipe.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.W_el_revenue = $START.pipe3.pipe.collectCosts.W_el_revenue (0.0 = $START.pipe3.pipe.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand (0.0 = $START.pipe2.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue (0.0 = $START.pipe2.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand (0.0 = $START.pipe2.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue (0.0 = $START.pipe2.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand (0.0 = $START.pipe2.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue (0.0 = $START.pipe2.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand (0.0 = $START.pipe2.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue (0.0 = $START.pipe2.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand (0.0 = $START.pipe1.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue (0.0 = $START.pipe1.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand (0.0 = $START.pipe1.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue (0.0 = $START.pipe1.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand (0.0 = $START.pipe1.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue (0.0 = $START.pipe1.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand (0.0 = $START.pipe1.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue (0.0 = $START.pipe1.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.other_demand = $START.pipe.collectCosts.other_demand (0.0 = $START.pipe.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.other_revenue = $START.pipe.collectCosts.other_revenue (0.0 = $START.pipe.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.H_demand = $START.pipe.collectCosts.H_demand (0.0 = $START.pipe.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.H_revenue = $START.pipe.collectCosts.H_revenue (0.0 = $START.pipe.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.Q_demand = $START.pipe.collectCosts.Q_demand (0.0 = $START.pipe.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.Q_revenue = $START.pipe.collectCosts.Q_revenue (0.0 = $START.pipe.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.W_el_demand = $START.pipe.collectCosts.W_el_demand (0.0 = $START.pipe.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.W_el_revenue = $START.pipe.collectCosts.W_el_revenue (0.0 = $START.pipe.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.m_CDE_consumed = $START.pipe4.pipe.collectCosts.m_CDE_consumed (0.0 = $START.pipe4.pipe.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe4.pipe.collectCosts.m_CDE_produced = $START.pipe4.pipe.collectCosts.m_CDE_produced (0.0 = $START.pipe4.pipe.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.m_CDE_consumed = $START.pipe3.pipe.collectCosts.m_CDE_consumed (0.0 = $START.pipe3.pipe.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe3.pipe.collectCosts.m_CDE_produced = $START.pipe3.pipe.collectCosts.m_CDE_produced (0.0 = $START.pipe3.pipe.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed (0.0 = $START.pipe2.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced (0.0 = $START.pipe2.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed (0.0 = $START.pipe1.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced (0.0 = $START.pipe1.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.m_CDE_consumed = $START.pipe.collectCosts.m_CDE_consumed (0.0 = $START.pipe.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: pipe.collectCosts.m_CDE_produced = $START.pipe.collectCosts.m_CDE_produced (0.0 = $START.pipe.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 2.006/9.65, allocations: 211.2 MB / 5.199 GB, free: 0.6964 GB / 2.405 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 0.0005463/9.65, allocations: 88.28 kB / 5.199 GB, free: 0.6963 GB / 2.405 GB Notification: Performance of matching and sorting (n=4583) (initialization_lambda0): time 0.1232/9.774, allocations: 57.95 MB / 5.256 GB, free: 0.6414 GB / 2.405 GB Notification: Performance of prepare postOptimizeDAE: time 0.0006816/9.774, allocations: 137.7 kB / 5.256 GB, free: 0.6413 GB / 2.405 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.003086/9.777, allocations: 0.9797 MB / 5.257 GB, free: 0.6403 GB / 2.405 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.01053/9.788, allocations: 4.341 MB / 5.261 GB, free: 0.636 GB / 2.405 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.03866/9.826, allocations: 5.717 MB / 5.267 GB, free: 0.6304 GB / 2.405 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.03303/9.86, allocations: 52.11 MB / 5.318 GB, free: 0.5764 GB / 2.405 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.04619/9.906, allocations: 2.981 MB / 5.321 GB, free: 0.5749 GB / 2.405 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01037/9.916, allocations: 1.469 MB / 5.322 GB, free: 0.5735 GB / 2.405 GB Warning: Assuming fixed start value for the following 39 variables: pipe4.pipe.h[1]:VARIABLE(start = pipe4.pipe.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe4.pipe.h[2]:VARIABLE(start = pipe4.pipe.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe4.pipe.h[3]:VARIABLE(start = pipe4.pipe.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe4.pipe.p[1]:VARIABLE(min = 0.0 start = pipe4.pipe.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe4.pipe.p[2]:VARIABLE(min = 0.0 start = pipe4.pipe.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe4.pipe.p[3]:VARIABLE(min = 0.0 start = pipe4.pipe.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] realGasCompositionByWtFractions_stepVariation.t_lastchange:VARIABLE(start = 0.0 unit = \"s\" fixed = true ) type: Real pipe_L4.h[1]:VARIABLE(start = pipe_L4.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer protected = true ) \"Cell enthalpy\" type: Real [3] pipe_L4.h[2]:VARIABLE(start = pipe_L4.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer protected = true ) \"Cell enthalpy\" type: Real [3] pipe1.h[1]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe1.h[2]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe1.h[3]:VARIABLE(start = pipe1.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe1.p[1]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe1.p[2]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe1.p[3]:VARIABLE(min = 0.0 start = pipe1.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] realGasCompositionByWtFractions_stepVariation.xi_in[1]:VARIABLE(min = 0.0 max = 1.0 start = 0.722090178 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] realGasCompositionByWtFractions_stepVariation.xi_in[2]:VARIABLE(min = 0.0 max = 1.0 start = 0.139591715 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] realGasCompositionByWtFractions_stepVariation.xi_in[3]:VARIABLE(min = 0.0 max = 1.0 start = 0.069014479 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] realGasCompositionByWtFractions_stepVariation.xi_in[4]:VARIABLE(min = 0.0 max = 1.0 start = 0.019245659 unit = \"1\" fixed = true nominal = 1.0 ) type: Real [6] pipe3.pipe.h[1]:VARIABLE(start = pipe3.pipe.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe3.pipe.h[2]:VARIABLE(start = pipe3.pipe.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe3.pipe.h[3]:VARIABLE(start = pipe3.pipe.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.never ) \"Cell enthalpy\" type: Real [3] pipe3.pipe.p[1]:VARIABLE(min = 0.0 start = pipe3.pipe.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe3.pipe.p[2]:VARIABLE(min = 0.0 start = pipe3.pipe.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe3.pipe.p[3]:VARIABLE(min = 0.0 start = pipe3.pipe.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipeFlow_L2_Simple.h[1]:VARIABLE(start = pipeFlow_L2_Simple.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer protected = true ) \"Cell enthalpy\" type: Real [1] pipeFlow_L2_Simple.p[1]:VARIABLE(min = 0.0 start = pipeFlow_L2_Simple.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 protected = true ) \"Cell pressure\" type: Real [1] pipe.h[1]:VARIABLE(start = pipe.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe.h[2]:VARIABLE(start = pipe.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe.h[3]:VARIABLE(start = pipe.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe.p[1]:VARIABLE(min = 0.0 start = pipe.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe.p[2]:VARIABLE(min = 0.0 start = pipe.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe.p[3]:VARIABLE(min = 0.0 start = pipe.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe2.h[1]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[1] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe2.h[2]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[2] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe2.h[3]:VARIABLE(start = pipe2.mechanicalEquilibrium.h_start[3] unit = \"J/kg\" fixed = true nominal = 1000.0 stateSelect=StateSelect.prefer ) \"Cell enthalpy\" type: Real [3] pipe2.p[1]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[1] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe2.p[2]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[2] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] pipe2.p[3]:VARIABLE(min = 0.0 start = pipe2.p_start_internal[3] unit = \"Pa\" fixed = true nominal = 1e5 stateSelect=StateSelect.prefer protected = true ) \"Cell pressure\" type: Real [3] Warning: The initial conditions are over specified. The following 112 initial equations are redundant, so they are removed from the initialization_lambda0 system: pipe4.pipe.collectCosts.other_demand = $START.pipe4.pipe.collectCosts.other_demand pipe4.pipe.collectCosts.other_revenue = $START.pipe4.pipe.collectCosts.other_revenue pipe4.pipe.collectCosts.H_demand = $START.pipe4.pipe.collectCosts.H_demand pipe4.pipe.collectCosts.H_revenue = $START.pipe4.pipe.collectCosts.H_revenue pipe4.pipe.collectCosts.Q_demand = $START.pipe4.pipe.collectCosts.Q_demand pipe4.pipe.collectCosts.Q_revenue = $START.pipe4.pipe.collectCosts.Q_revenue pipe4.pipe.collectCosts.W_el_demand = $START.pipe4.pipe.collectCosts.W_el_demand pipe4.pipe.collectCosts.W_el_revenue = $START.pipe4.pipe.collectCosts.W_el_revenue pipe3.pipe.collectCosts.other_demand = $START.pipe3.pipe.collectCosts.other_demand pipe3.pipe.collectCosts.other_revenue = $START.pipe3.pipe.collectCosts.other_revenue pipe3.pipe.collectCosts.H_demand = $START.pipe3.pipe.collectCosts.H_demand pipe3.pipe.collectCosts.H_revenue = $START.pipe3.pipe.collectCosts.H_revenue pipe3.pipe.collectCosts.Q_demand = $START.pipe3.pipe.collectCosts.Q_demand pipe3.pipe.collectCosts.Q_revenue = $START.pipe3.pipe.collectCosts.Q_revenue pipe3.pipe.collectCosts.W_el_demand = $START.pipe3.pipe.collectCosts.W_el_demand pipe3.pipe.collectCosts.W_el_revenue = $START.pipe3.pipe.collectCosts.W_el_revenue pipe2.collectCosts.other_demand = $START.pipe2.collectCosts.other_demand pipe2.collectCosts.other_revenue = $START.pipe2.collectCosts.other_revenue pipe2.collectCosts.H_demand = $START.pipe2.collectCosts.H_demand pipe2.collectCosts.H_revenue = $START.pipe2.collectCosts.H_revenue pipe2.collectCosts.Q_demand = $START.pipe2.collectCosts.Q_demand pipe2.collectCosts.Q_revenue = $START.pipe2.collectCosts.Q_revenue pipe2.collectCosts.W_el_demand = $START.pipe2.collectCosts.W_el_demand pipe2.collectCosts.W_el_revenue = $START.pipe2.collectCosts.W_el_revenue pipe1.collectCosts.other_demand = $START.pipe1.collectCosts.other_demand pipe1.collectCosts.other_revenue = $START.pipe1.collectCosts.other_revenue pipe1.collectCosts.H_demand = $START.pipe1.collectCosts.H_demand pipe1.collectCosts.H_revenue = $START.pipe1.collectCosts.H_revenue pipe1.collectCosts.Q_demand = $START.pipe1.collectCosts.Q_demand pipe1.collectCosts.Q_revenue = $START.pipe1.collectCosts.Q_revenue pipe1.collectCosts.W_el_demand = $START.pipe1.collectCosts.W_el_demand pipe1.collectCosts.W_el_revenue = $START.pipe1.collectCosts.W_el_revenue pipe.collectCosts.other_demand = $START.pipe.collectCosts.other_demand pipe.collectCosts.other_revenue = $START.pipe.collectCosts.other_revenue pipe.collectCosts.H_demand = $START.pipe.collectCosts.H_demand pipe.collectCosts.H_revenue = $START.pipe.collectCosts.H_revenue pipe.collectCosts.Q_demand = $START.pipe.collectCosts.Q_demand pipe.collectCosts.Q_revenue = $START.pipe.collectCosts.Q_revenue pipe.collectCosts.W_el_demand = $START.pipe.collectCosts.W_el_demand pipe.collectCosts.W_el_revenue = $START.pipe.collectCosts.W_el_revenue modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] pipe4.pipe.collectCosts.m_CDE_consumed = $START.pipe4.pipe.collectCosts.m_CDE_consumed pipe4.pipe.collectCosts.m_CDE_produced = $START.pipe4.pipe.collectCosts.m_CDE_produced pipe3.pipe.collectCosts.m_CDE_consumed = $START.pipe3.pipe.collectCosts.m_CDE_consumed pipe3.pipe.collectCosts.m_CDE_produced = $START.pipe3.pipe.collectCosts.m_CDE_produced pipe2.collectCosts.m_CDE_consumed = $START.pipe2.collectCosts.m_CDE_consumed pipe2.collectCosts.m_CDE_produced = $START.pipe2.collectCosts.m_CDE_produced pipe1.collectCosts.m_CDE_consumed = $START.pipe1.collectCosts.m_CDE_consumed pipe1.collectCosts.m_CDE_produced = $START.pipe1.collectCosts.m_CDE_produced pipe.collectCosts.m_CDE_consumed = $START.pipe.collectCosts.m_CDE_consumed pipe.collectCosts.m_CDE_produced = $START.pipe.collectCosts.m_CDE_produced modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1410 * Number of states: 0 () * Number of discrete variables: 16 ($whenCondition3,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,pipeFlow_L2_Simple.heatTransfer.table_block.tableID,pipe1.heatTransfer.table_block.tableID,pipe_L4.heatTransfer.table_block.tableID,pipe.heatTransfer.table_block.tableID,pipe2.heatTransfer.table_block.tableID) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (2624): * Single equations (assignments): 2410 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 172 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 15 * Torn equation systems: 27 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 15 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 22 systems {(1,1,100.0%), (1,1,100.0%), (1,2,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,2,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 5 systems {(2,6), (1,5), (5,57), (1,8), (1,8)} Notification: Performance of prepare postOptimizeDAE: time 0.01985/9.936, allocations: 3.03 MB / 5.325 GB, free: 0.5706 GB / 2.405 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.0179/9.954, allocations: 3.424 MB / 5.328 GB, free: 0.5676 GB / 2.405 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.09797/10.05, allocations: 42.49 MB / 5.37 GB, free: 0.526 GB / 2.405 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.0005248/10.05, allocations: 188 kB / 5.37 GB, free: 0.5258 GB / 2.405 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0001574/10.05, allocations: 20 kB / 5.37 GB, free: 0.5258 GB / 2.405 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.08615/10.14, allocations: 41.74 MB / 5.411 GB, free: 496.3 MB / 2.405 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.09497/10.23, allocations: 36.73 MB / 5.447 GB, free: 460.2 MB / 2.405 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.002535/10.24, allocations: 0.6792 MB / 5.447 GB, free: 459.5 MB / 2.405 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.02899/10.27, allocations: 3.012 MB / 5.45 GB, free: 456.5 MB / 2.405 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.009565/10.27, allocations: 3.246 MB / 5.453 GB, free: 453.2 MB / 2.405 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.007096/10.28, allocations: 0.6207 MB / 5.454 GB, free: 452.6 MB / 2.405 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.03507/10.32, allocations: 55.57 MB / 5.508 GB, free: 393.1 MB / 2.405 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.071e-05/10.32, allocations: 19.88 kB / 5.508 GB, free: 393.1 MB / 2.405 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1362/10.45, allocations: 70 MB / 5.577 GB, free: 322.7 MB / 2.405 GB Notification: Performance of postOpt removeConstants (simulation): time 0.02878/10.48, allocations: 8.743 MB / 5.585 GB, free: 314.3 MB / 2.405 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0151/10.5, allocations: 399.9 kB / 5.586 GB, free: 313.9 MB / 2.405 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.02703/10.52, allocations: 0.6788 MB / 5.586 GB, free: 313.2 MB / 2.405 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.009373/10.53, allocations: 0.9614 MB / 5.587 GB, free: 312.3 MB / 2.405 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.008798/10.54, allocations: 0.8082 MB / 5.588 GB, free: 311.5 MB / 2.405 GB Notification: Performance of sorting global known variables: time 0.05618/10.6, allocations: 23.25 MB / 5.611 GB, free: 288.4 MB / 2.405 GB Notification: Performance of sort global known variables: time 4.01e-07/10.6, allocations: 4 kB / 5.611 GB, free: 288.4 MB / 2.405 GB Notification: Performance of remove unused functions: time 0.08329/10.68, allocations: 14.9 MB / 5.625 GB, free: 274 MB / 2.405 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 52 * Number of states: 117 (pipe4.pipe.h[1],pipe4.pipe.h[2],pipe4.pipe.h[3],pipe4.pipe.p[1],pipe4.pipe.p[2],pipe4.pipe.p[3],pipe2.h[1],pipe2.h[2],pipe2.h[3],pipe2.p[1],pipe2.p[2],pipe2.p[3],pipe.h[1],pipe.h[2],pipe.h[3],pipe.p[1],pipe.p[2],pipe.p[3],pipe.xi[1,1],pipe.xi[1,2],pipe.xi[1,3],pipe.xi[1,4],pipe.xi[1,5],pipe.xi[1,6],pipe.xi[2,1],pipe.xi[2,2],pipe.xi[2,3],pipe.xi[2,4],pipe.xi[2,5],pipe.xi[2,6],pipe.xi[3,1],pipe.xi[3,2],pipe.xi[3,3],pipe.xi[3,4],pipe.xi[3,5],pipe.xi[3,6],pipe_L4.h[1],pipe_L4.h[2],pipe_L4.h[3],pipe_L4.p[1],pipe_L4.p[2],pipe_L4.p[3],pipe_L4.xi[1,1],pipe_L4.xi[1,2],pipe_L4.xi[1,3],pipe_L4.xi[1,4],pipe_L4.xi[1,5],pipe_L4.xi[1,6],pipe_L4.xi[2,1],pipe_L4.xi[2,2],pipe_L4.xi[2,3],pipe_L4.xi[2,4],pipe_L4.xi[2,5],pipe_L4.xi[2,6],pipe_L4.xi[3,1],pipe_L4.xi[3,2],pipe_L4.xi[3,3],pipe_L4.xi[3,4],pipe_L4.xi[3,5],pipe_L4.xi[3,6],pipe1.h[1],pipe1.h[2],pipe1.h[3],pipe1.p[1],pipe1.p[2],pipe1.p[3],pipe1.xi[1,1],pipe1.xi[1,2],pipe1.xi[1,3],pipe1.xi[1,4],pipe1.xi[1,5],pipe1.xi[1,6],pipe1.xi[2,1],pipe1.xi[2,2],pipe1.xi[2,3],pipe1.xi[2,4],pipe1.xi[2,5],pipe1.xi[2,6],pipe1.xi[3,1],pipe1.xi[3,2],pipe1.xi[3,3],pipe1.xi[3,4],pipe1.xi[3,5],pipe1.xi[3,6],realGasCompositionByWtFractions_stepVariation.xi_in[1],realGasCompositionByWtFractions_stepVariation.xi_in[2],realGasCompositionByWtFractions_stepVariation.xi_in[3],realGasCompositionByWtFractions_stepVariation.xi_in[4],realGasCompositionByWtFractions_stepVariation.xi_in[5],realGasCompositionByWtFractions_stepVariation.xi_in[6],realGasCompositionByWtFractions_stepVariation.t_lastchange,pipe3.pipe.h[1],pipe3.pipe.h[2],pipe3.pipe.h[3],pipe3.pipe.p[1],pipe3.pipe.p[2],pipe3.pipe.p[3],pipe3.pipe.xi[1,1],pipe3.pipe.xi[1,2],pipe3.pipe.xi[1,3],pipe3.pipe.xi[1,4],pipe3.pipe.xi[1,5],pipe3.pipe.xi[1,6],pipe3.pipe.xi[2,1],pipe3.pipe.xi[2,2],pipe3.pipe.xi[2,3],pipe3.pipe.xi[2,4],pipe3.pipe.xi[2,5],pipe3.pipe.xi[2,6],pipe3.pipe.xi[3,1],pipe3.pipe.xi[3,2],pipe3.pipe.xi[3,3],pipe3.pipe.xi[3,4],pipe3.pipe.xi[3,5],pipe3.pipe.xi[3,6],pipeFlow_L2_Simple.h[1],pipeFlow_L2_Simple.p[1]) * Number of discrete variables: 12 (pipe2.heatTransfer.table_block.tableID,pipe.heatTransfer.table_block.tableID,$whenCondition3,pipe_L4.heatTransfer.table_block.tableID,pipe1.heatTransfer.table_block.tableID,pipeFlow_L2_Simple.heatTransfer.table_block.tableID,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled) * Number of discrete states: 10 (simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,realGasCompositionByWtFractions_stepVariation.xi_in[1],realGasCompositionByWtFractions_stepVariation.xi_in[2],realGasCompositionByWtFractions_stepVariation.xi_in[3],realGasCompositionByWtFractions_stepVariation.xi_in[4],realGasCompositionByWtFractions_stepVariation.xi_in[5],realGasCompositionByWtFractions_stepVariation.xi_in[6]) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (1209): * Single equations (assignments): 983 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 174 * When equations: 9 * If-equations: 0 * Equation systems (not torn): 15 * Torn equation systems: 28 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 15 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 25 systems {(1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 3 systems {(1,8), (1,8), (1,8)} [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:116:25-117:61:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.2-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:118:25-119:60:writable] Warning: Could not find library TILMedia182ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /lib/x86_64-linux-gnu/libTILMedia182ClaRa.a /usr/lib//libTILMedia182ClaRa.a /lib//libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /lib/x86_64-linux-gnu/libTILMedia182ClaRa.so /usr/lib//libTILMedia182ClaRa.so /lib//libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia182ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia182ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia182ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.0126/10.69, allocations: 2.083 MB / 5.627 GB, free: 272.7 MB / 2.405 GB Notification: Performance of simCode: created initialization part: time 0.1489/10.84, allocations: 90.75 MB / 5.716 GB, free: 179.3 MB / 2.405 GB Notification: Performance of simCode: created event and clocks part: time 3.158e-05/10.84, allocations: 9.125 kB / 5.716 GB, free: 179.3 MB / 2.405 GB Notification: Performance of simCode: created simulation system equations: time 0.04398/10.89, allocations: 30.61 MB / 5.746 GB, free: 147.3 MB / 2.405 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.06421/10.95, allocations: 8.826 MB / 5.754 GB, free: 138.5 MB / 2.405 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[3,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[3,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[3,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[3,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[3,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[3,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[2,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[2,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[2,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[2,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[2,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[2,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[1,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[1,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[1,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[1,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[1,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe3.pipe.xi[1,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:260:3-260:122:writable] Warning: Variable pipe3.pipe.h[3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:260:3-260:122:writable] Warning: Variable pipe3.pipe.h[2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:260:3-260:122:writable] Warning: Variable pipe3.pipe.h[1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[3,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[2,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe1.xi[1,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[3,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[3,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[3,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[3,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[3,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[3,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[2,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[2,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[2,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[2,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[2,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[2,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[1,6] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[1,5] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[1,4] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[1,3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[1,2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:286:3-286:252:writable] Warning: Variable pipe.xi[1,1] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:260:3-260:122:writable] Warning: Variable pipe4.pipe.h[3] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:260:3-260:122:writable] Warning: Variable pipe4.pipe.h[2] has attribute stateSelect=StateSelect.never, but was selected as a state [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/VolumesValvesFittings/Base/VolumeRealGas_L4.mo:260:3-260:122:writable] Warning: Variable pipe4.pipe.h[1] has attribute stateSelect=StateSelect.never, but was selected as a state Warning: The hideResult annotation could not be evaluated, probably due to missing annotation(Evaluate=true). It is removed. Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.195/11.15, allocations: 90.44 MB / 5.843 GB, free: 47.96 MB / 2.405 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.04839/11.19, allocations: 18.65 MB / 5.861 GB, free: 29.26 MB / 2.405 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.02312/11.22, allocations: 2.444 MB / 5.863 GB, free: 26.81 MB / 2.405 GB Notification: Performance of SimCode: time 2.725e-06/11.22, allocations: 4 kB / 5.863 GB, free: 26.81 MB / 2.405 GB Notification: Performance of Templates: time 17.96/29.18, allocations: 6.332 GB / 12.2 GB, free: 241.3 MB / 2.514 GB " [Timeout remaining time 631] make -j1 -f TransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes.makefile [Timeout 660] make -j1 -f TransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/include/omc/sundials" "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesCalcHelperMain.o OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesCalcHelperMain.cpp In file included from OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesCalcHelperMain.cpp:28: ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1290:25: error: no matching function for call to 'TILMedia_createExternalObject' externalObject__ext = TILMedia_createExternalObject(objectType_.c_str(), mediumName_.c_str(), flags__ext, ConstArray(xi_).getData(), nc__ext, condensingIndex__ext, instanceName_.c_str()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:59:7: note: candidate function not viable: 4th argument ('const double *') would lose const qualifier void* TILMedia_createExternalObject(const char* objectType, const char* mixtureName, int flags, double* xi, int _nc, int condensingIndex, const char* instanceName) { ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1335:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_density_pTxi' d__ext = TILMedia_VLEFluidObjectFunctions_density_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:19:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_density_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1361:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_density_phxi' d__ext = TILMedia_VLEFluid_Cached_density_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:18:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_density_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1387:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:17:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1413:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi' s__ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:16:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1439:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi' s__ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:15:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1465:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_temperature_phxi' T__ext = TILMedia_VLEFluidObjectFunctions_temperature_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:14:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_temperature_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1491:12: error: no matching function for call to 'TILMedia_VLEFluidFunctions_density_phxi' d__ext = TILMedia_VLEFluidFunctions_density_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:13:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_density_phxi(double, double, double*,const char*, int); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1566:3: error: no matching function for call to 'TILMedia_VLEFluid_VLEProperties_phxi' TILMedia_VLEFluid_VLEProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &d_l__ext, &h_l__ext, &p_l__ext, &s_l__ext, &T_l__ext, xi_l_.getData(), &d_v__ext, &h_v__ext, &p_v__ext, &s_v__ext, &T_v__ext, xi_v_.getData()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:11:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_VLEProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1663:3: error: no matching function for call to 'TILMedia_VLEFluid_additionalProperties_phxi' TILMedia_VLEFluid_additionalProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &x__ext, &cp__ext, &cv__ext, &beta__ext, &kappa__ext, &drhodp__ext, &drhodh__ext, drhodxi_.getData(), &a__ext, &gamma__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:10:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_additionalProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1730:3: error: no matching function for call to 'TILMedia_VLEFluid_cricondenbar_xi' TILMedia_VLEFluid_cricondenbar_xi(ConstArray(xi_).getData(), vleFluidPointer__ext, &d__ext, &h__ext, &p__ext, &s__ext, &T__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:9:6: note: candidate function not viable: 1st argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_cricondenbar_xi(double*, void*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:1783:3: error: no matching function for call to 'TILMedia_VLEFluid_transportProperties_phxi' TILMedia_VLEFluid_transportProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &Pr__ext, &lambda__ext, &eta__ext, &sigma__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:8:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_transportProperties_phxi(double, double, double*, void*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:2129:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:2155:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:2181:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:2207:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:2233:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:2259:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ In file included from OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesCalcHelperMain.cpp:33: ./OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipes.cpp:17469:16: error: assigning to 'double' from incompatible type 'StatArrayDim1' __z[111] = tmp3083; ^~~~~~~ 19 errors generated. make: *** [: OMCppTransiEnt_TransiEnt.Components.Gas.VolumesValvesFittings.Check.CheckPipesCalcHelperMain.o] Error 1 [Calling os._exit(0), Time elapsed: 48.9804062678013] Failed to read output from testmodel.py, exit status != 0: 29.19234355399385 29.201652565 25.868323159 Calling exit ...