Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 1.01/1.01, allocations: 152.6 MB / 169.6 MB, free: 14.93 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50") translateModel(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50,tolerance=0.001,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.0005172/0.0005172, allocations: 16.12 kB / 245.7 MB, free: 15.57 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.06703/0.06755, allocations: 33.06 MB / 278.7 MB, free: 0.5625 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50): time 1.941/2.009, allocations: 414.4 MB / 0.6769 GB, free: 1.031 MB / 0.545 GB Notification: Performance of NFInst.instExpressions: time 0.7687/2.778, allocations: 254.5 MB / 0.9254 GB, free: 11.99 MB / 0.7012 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.03739/2.815, allocations: 457.8 kB / 0.9258 GB, free: 11.54 MB / 0.7012 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:109:3-111:57:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeB.mo:112:3-113:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:134:3-135:75:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:136:3-137:75:writable] Warning: Connector Cm is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:138:3-139:77:writable] Warning: Connector Cd is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:140:3-141:65:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:155:3-157:58:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:158:3-159:76:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/DynamicDrum.mo:160:3-161:66:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:123:3-124:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/StaticWallFlueGasesExchanger.mo:127:3-128:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:233:3-234:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:237:3-238:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:82:3-83:51:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:84:3-85:53:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:86:3-87:54:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/DynamicFlueGasesMultiFluidHeatExchanger.mo:88:3-89:52:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:65:3-66:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:67:3-68:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StodolaTurbine.mo:72:3-76:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:119:3-120:52:writable] Warning: Connector Cv is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:121:3-122:53:writable] Warning: Connector Cl is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:129:3-130:55:writable] Warning: Connector Cee is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/HeatExchangers/SimpleDynamicCondenser.mo:131:3-132:53:writable] Warning: Connector Cse is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourceQ.mo:62:3-63:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SinkP.mo:46:3-47:67:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:104:3-105:67:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:109:3-110:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeA.mo:111:3-112:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:43:3-44:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Junctions/MassFlowMultiplier.mo:45:3-46:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:63:3-64:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/StaticCentrifugalPump.mo:65:3-66:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:10:3-11:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Sensors/SensorQ.mo:12:3-13:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:33:3-34:67:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/PipePressureLoss.mo:35:3-36:65:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:104:3-105:67:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:106:3-107:73:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:108:3-109:75:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeD.mo:110:3-111:71:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:103:3-105:59:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:106:3-108:57:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:109:3-110:65:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Volumes/VolumeC.mo:111:3-113:24:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:44:3-45:68:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/PressureLosses/ControlValve.mo:46:3-47:66:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Combustion/BoundaryConditions/FuelSourcePQ.mo:26:3-28:26:writable] Warning: Connector C is not balanced: The number of potential variables (13) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/SourcePQ.mo:74:3-75:65:writable] Warning: Connector C is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/AirHumidity.mo:39:3-40:54:writable] Warning: Connector C1 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/BoundaryConditions/AirHumidity.mo:47:3-48:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/Compressor.mo:50:3-51:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/Compressor.mo:52:3-53:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:102:3-104:16:writable] Warning: Connector Cfuel is not balanced: The number of potential variables (13) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:105:3-107:16:writable] Warning: Connector Ca is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:108:3-109:83:writable] Warning: Connector Cfg is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Combustion/CombustionChambers/GTCombustionChamber.mo:110:3-112:17:writable] Warning: Connector Cws is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/CombustionTurbine.mo:40:3-41:54:writable] Warning: Connector Ce is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/CombustionTurbine.mo:42:3-43:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/GasTurbine.mo:57:3-58:65:writable] Warning: Connector Entree_air is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/GasTurbine.mo:59:3-60:63:writable] Warning: Connector Sortie_fumees is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/GasTurbine.mo:61:3-62:66:writable] Warning: Connector Entree_eau_combustion is not balanced: The number of potential variables (9) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Fluid/Machines/GasTurbine.mo:63:3-64:82:writable] Warning: Connector Entree_combustible is not balanced: The number of potential variables (13) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.02897/2.844, allocations: 6.38 MB / 0.9321 GB, free: 5.156 MB / 0.7012 GB Notification: Performance of NFTyping.typeBindings: time 0.06273/2.907, allocations: 18.72 MB / 0.9504 GB, free: 2.324 MB / 0.7169 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/Fluid/derDensity_derP_derh.mo:63:5-63:84:writable] Warning: T was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.1056/3.012, allocations: 37.3 MB / 0.9868 GB, free: 13.11 MB / 0.7637 GB Notification: Performance of NFFlatten.flatten: time 0.6422/3.654, allocations: 112.3 MB / 1.097 GB, free: 34.35 MB / 0.7637 GB Notification: Performance of NFFlatten.resolveConnections: time 0.06825/3.723, allocations: 34.82 MB / 1.131 GB, free: 11.48 MB / 0.7637 GB Notification: Performance of NFEvalConstants.evaluate: time 0.08877/3.811, allocations: 37.26 MB / 1.167 GB, free: 8.375 MB / 0.795 GB Notification: Performance of NFSimplifyModel.simplify: time 0.09332/3.905, allocations: 42.37 MB / 1.208 GB, free: 428 kB / 0.8262 GB Notification: Performance of NFPackage.collectConstants: time 0.04196/3.947, allocations: 8.563 MB / 1.217 GB, free: 7.855 MB / 0.8419 GB Notification: Performance of NFFlatten.collectFunctions: time 0.1277/4.074, allocations: 41.6 MB / 1.257 GB, free: 15.41 MB / 0.8887 GB Notification: Performance of NFScalarize.scalarize: time 0.05112/4.126, allocations: 25.07 MB / 1.282 GB, free: 6.805 MB / 0.9044 GB Notification: Performance of NFVerifyModel.verify: time 0.1044/4.23, allocations: 35.96 MB / 1.317 GB, free: 3.145 MB / 0.9356 GB Notification: Performance of NFConvertDAE.convert: time 1.329/5.559, allocations: 109.9 MB / 1.424 GB, free: 116 MB / 0.9513 GB Notification: Performance of FrontEnd - DAE generated: time 7.104e-06/5.559, allocations: 0.6562 kB / 1.424 GB, free: 116 MB / 0.9513 GB Notification: Performance of FrontEnd: time 2.615e-06/5.559, allocations: 0 / 1.424 GB, free: 116 MB / 0.9513 GB Notification: Performance of Transformations before backend: time 0.00472/5.563, allocations: 2.469 kB / 1.424 GB, free: 116 MB / 0.9513 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 15489 * Number of variables: 15489 Notification: Performance of Generate backend data structure: time 0.3306/5.894, allocations: 74.58 MB / 1.497 GB, free: 81.94 MB / 0.9513 GB Notification: Performance of prepare preOptimizeDAE: time 4.74e-05/5.894, allocations: 15.72 kB / 1.497 GB, free: 81.94 MB / 0.9513 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.043/5.937, allocations: 6.503 MB / 1.503 GB, free: 78.67 MB / 0.9513 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.08171/6.019, allocations: 24.66 MB / 1.527 GB, free: 62.86 MB / 0.9513 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.02257/6.041, allocations: 15.69 MB / 1.543 GB, free: 46.3 MB / 0.9513 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.03529/6.076, allocations: 4.836 MB / 1.547 GB, free: 41.47 MB / 0.9513 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.3382/6.415, allocations: 98.17 MB / 1.643 GB, free: 3.82 MB / 1.014 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.002832/6.417, allocations: 192.7 kB / 1.644 GB, free: 3.746 MB / 1.014 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.03231/6.45, allocations: 2.02 MB / 1.646 GB, free: 1.727 MB / 1.014 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.002468/6.452, allocations: 1.749 MB / 1.647 GB, free: 15.98 MB / 1.029 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.7108/7.163, allocations: 115.5 MB / 1.76 GB, free: 499.4 MB / 1.076 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.7788/7.942, allocations: 438.9 MB / 2.189 GB, free: 123.1 MB / 1.076 GB Notification: Performance of preOpt comSubExp (simulation): time 0.2018/8.144, allocations: 82.33 MB / 2.269 GB, free: 40.4 MB / 1.076 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.592/8.736, allocations: 55.98 MB / 2.324 GB, free: 494.6 MB / 1.076 GB Notification: Performance of preOpt evalFunc (simulation): time 1.846/10.58, allocations: 0.7185 GB / 3.042 GB, free: 393.7 MB / 1.076 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.195/10.78, allocations: 63.26 MB / 3.104 GB, free: 372.6 MB / 1.076 GB Notification: Performance of pre-optimization done (n=7826): time 9.201e-05/10.78, allocations: 0 / 3.104 GB, free: 372.6 MB / 1.076 GB Notification: Performance of matching and sorting (n=7834): time 1.916/12.69, allocations: 411.1 MB / 3.505 GB, free: 400.7 MB / 1.076 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0005538/12.69, allocations: 1.578 MB / 3.507 GB, free: 398.9 MB / 1.076 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.0437/12.74, allocations: 20.57 MB / 3.527 GB, free: 381.8 MB / 1.076 GB Notification: Performance of collectPreVariables (initialization): time 0.02398/12.76, allocations: 0.7985 MB / 3.528 GB, free: 381 MB / 1.076 GB Notification: Performance of collectInitialEqns (initialization): time 0.01773/12.78, allocations: 17.23 MB / 3.545 GB, free: 365.8 MB / 1.076 GB Notification: Performance of collectInitialBindings (initialization): time 0.04846/12.83, allocations: 27.99 MB / 3.572 GB, free: 340.5 MB / 1.076 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.09361/12.92, allocations: 13.34 MB / 3.585 GB, free: 329.2 MB / 1.076 GB Notification: Performance of setup shared object (initialization): time 6.295e-05/12.92, allocations: 301.1 kB / 3.585 GB, free: 328.9 MB / 1.076 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.6018/13.52, allocations: 52.2 MB / 3.636 GB, free: 478.9 MB / 1.076 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.1691/13.69, allocations: 67.52 MB / 3.702 GB, free: 452.5 MB / 1.076 GB Notification: Performance of analyzeInitialSystem (initialization): time 1.859/15.55, allocations: 358.3 MB / 4.052 GB, free: 405.4 MB / 1.076 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.00106/15.55, allocations: 119 kB / 4.052 GB, free: 405.4 MB / 1.076 GB Notification: Performance of matching and sorting (n=10158) (initialization): time 1.063/16.61, allocations: 169.3 MB / 4.217 GB, free: 428 MB / 1.076 GB Notification: Performance of prepare postOptimizeDAE: time 0.0004498/16.61, allocations: 238.1 kB / 4.218 GB, free: 428 MB / 1.076 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.00157/16.62, allocations: 0.5118 MB / 4.218 GB, free: 428 MB / 1.076 GB Notification: Performance of postOpt tearingSystem (initialization): time 7.563/24.18, allocations: 2.449 GB / 6.667 GB, free: 325.8 MB / 1.076 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.04392/24.22, allocations: 8.227 MB / 6.675 GB, free: 319.8 MB / 1.076 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 1.064/25.29, allocations: 188.1 MB / 6.859 GB, free: 412.5 MB / 1.076 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.09969/25.39, allocations: 6.982 MB / 6.865 GB, free: 411.7 MB / 1.076 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.03396/25.42, allocations: 3.001 MB / 6.868 GB, free: 411.2 MB / 1.076 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP4.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurMP3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1853 * Number of states: 0 () * Number of discrete variables: 415 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,VolumeAlimMPHP.Cs1.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,vanne_extraction.C2.diff_on_1,perteChargeK2.C2.diff_on_1,GasTurbine.chambreCombustionTAC.Cfg.ftype,SourceFumees.C.ftype,GasTurbine.chambreCombustionTAC.fluids[1],DoubleDebitMP.Cs.ftype,MelangeurPreTMP.Cs.ftype,MelangeurPreTMP.Ce3.ftype,MelangeurPreTMP.Ce2.ftype,MelangeurPreTMP.fluids[1],VolumePreTHP.Cs3.ftype,VolumePreTHP.Cs2.ftype,VolumePreTHP.Cs1.ftype,DoubleDebitHP.Cs.ftype,VolumePreTHP.fluids[1],VolumeAlimMPHP.Cs1.ftype,VolumeAlimMPHP.Cs2.ftype,VolumeECO_HP2_3.Cs.ftype,VolumeECO_HP2_3.Ce3.ftype,VolumeECO_HP2_3.Ce2.ftype,VolumeECO_HP1_2.Cs.ftype,VolumeECO_HP2_3.fluids[1],VolumeECO_HP1_2.Ce3.ftype,VolumeECO_HP1_2.Ce2.ftype,VolumeECO_HP1_2.fluids[1],regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,MelangeurHPMP.Cs2.ftype,MelangeurPostTMP1.Cs.ftype,Condenseur.Cl.ftype,BallonBP.Cs.ftype,VolumeCond1.Cs.ftype,BallonBP.Cv.ftype,BallonMP.Cv.ftype,BallonHP.Cv.ftype,DoubleDebitBP.Cs.ftype,DoubleDebitBP.fluids[1],MoitieDebitBP.Cs.ftype,MoitieDebitBP.fluids[1],VolumeAlimMPHP.Ce2.ftype,VolumeAlimMPHP.fluids[1],VolumeCond1.Ce2.ftype,VolumeCond1.Ce1.ftype,VolumeCond1.fluids[1],SourceCaloporteur.C.ftype,MoitieDebitHP.Cs.ftype,MoitieDebitHP.fluids[1],DoubleDebitMP.fluids[1],DoubleDebitHP.fluids[1],MelangeurPostTMP1.Ce3.ftype,MelangeurPostTMP1.fluids[1],VolumeEvapBP.Cs.ftype,VolumeEvapBP.Ce3.ftype,VolumeEvapBP.Ce2.ftype,BallonBP.Cd.ftype,VolumeEvapBP.fluids[1],BallonBP.Ce3.ftype,BallonBP.Ce2.ftype,BallonBP.fluids[1],MelangeurHPMP.Cs1.ftype,MelangeurHPMP.fluids[1],VolumeEvapMP.Cs.ftype,VolumeEvapMP.Ce3.ftype,VolumeEvapMP.Ce2.ftype,BallonMP.Cd.ftype,VolumeEvapMP.fluids[1],BallonMP.Cs.ftype,BallonMP.Ce3.ftype,BallonMP.Ce2.ftype,BallonMP.fluids[1],VolumeEvapHP.Cs.ftype,VolumeEvapHP.Ce3.ftype,VolumeEvapHP.Ce2.ftype,BallonHP.Cd.ftype,VolumeEvapHP.fluids[1],BallonHP.Cs.ftype,BallonHP.Ce3.ftype,BallonHP.Ce2.ftype,BallonHP.fluids[1],GasTurbine.xAIR.fluid,GasTurbine.Compresseur.fluid,vanne_alimentationHP.fluid,vanne_vapeurHP.fluid,GainChargeHP.fluid,EvaporateurHP.ExchangerFlueGasesMetal.fluid,EvaporateurHP.TwoPhaseFlowPipe.fluid,EconomiseurHP4.ExchangerFlueGasesMetal.fluid,EconomiseurHP4.TwoPhaseFlowPipe.fluid,SurchauffeurHP1.ExchangerFlueGasesMetal.fluid,SurchauffeurHP1.TwoPhaseFlowPipe.fluid,EconomiseurHP3.ExchangerFlueGasesMetal.fluid,EconomiseurHP3.TwoPhaseFlowPipe.fluid,EconomiseurHP2.ExchangerFlueGasesMetal.fluid,EconomiseurHP2.TwoPhaseFlowPipe.fluid,EconomiseurHP1.ExchangerFlueGasesMetal.fluid,EconomiseurHP1.TwoPhaseFlowPipe.fluid,SurchauffeurHP2.ExchangerFlueGasesMetal.fluid,SurchauffeurHP2.TwoPhaseFlowPipe.fluid,SurchauffeurHP3.ExchangerFlueGasesMetal.fluid,SurchauffeurHP3.TwoPhaseFlowPipe.fluid,vanne_alimentationMP.fluid,vanne_vapeurMP.fluid,EvaporateurMP.ExchangerFlueGasesMetal.fluid,EvaporateurMP.TwoPhaseFlowPipe.fluid,GainChargeMP.fluid,EconomiseurMP.ExchangerFlueGasesMetal.fluid,EconomiseurMP.TwoPhaseFlowPipe.fluid,SurchauffeurMP1.ExchangerFlueGasesMetal.fluid,SurchauffeurMP1.TwoPhaseFlowPipe.fluid,SurchauffeurMP2.ExchangerFlueGasesMetal.fluid,SurchauffeurMP2.TwoPhaseFlowPipe.fluid,SurchauffeurMP3.ExchangerFlueGasesMetal.fluid,SurchauffeurMP3.TwoPhaseFlowPipe.fluid,vanne_vapeurBP.fluid,vanne_alimentationBP.fluid,GainChargeBP.fluid,EvaporateurBP.ExchangerFlueGasesMetal.fluid,EvaporateurBP.TwoPhaseFlowPipe.fluid,Vanne_alimentationMPHP.fluid,SurchauffeurBP.ExchangerFlueGasesMetal.fluid,SurchauffeurBP.TwoPhaseFlowPipe.fluid,PuitsFumees.fluid,EconomiseurBP.ExchangerFlueGasesMetal.fluid,EconomiseurBP.TwoPhaseFlowPipe.fluid,TurbineHP.fluid,TurbineMP.fluid,TurbineBP.fluid,Condenseur.fluid_p,PuitsCaloporteur.fluid,perteChargeK1.fluid,perteChargeKCond1.fluid,PompeAlimMP.fluid,PompeAlimHP.fluid,PerteChargeZero2.fluid,perteChargeK3.fluid,perteChargeK8.fluid,perteChargeK.fluid,PompeAlimBP.fluid,perteChargeK2.fluid,vanne_extraction.fluid,lumpedStraightPipeK2.fluid,vanne_entree_TurbineHP.fluid,Vanne_alimentationMPHP1.fluid,Vanne_alimentationMPHP2.fluid,vanne_entree_TurbineMP.fluid,GasTurbine.TurbineAgaz.fluid,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1,sourceEau.C.ftype,GasTurbine.chambreCombustionTAC.fluid_ws,SourceFumees.fluid1,sourceEau.fluid1,MelangeurPreTMP.fluid1,VolumePreTHP.fluid1,VolumeECO_HP2_3.fluid1,VolumeECO_HP1_2.fluid1,DoubleDebitBP.fluid1,MoitieDebitBP.fluid1,VolumeAlimMPHP.fluid1,VolumeCond1.fluid1,SourceCaloporteur.fluid1,MoitieDebitHP.fluid1,DoubleDebitMP.fluid1,DoubleDebitHP.fluid1,MelangeurPostTMP1.fluid1,VolumeEvapBP.fluid1,MelangeurHPMP.fluid1,VolumeEvapMP.fluid1,VolumeEvapHP.fluid1,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,GasTurbine.chambreCombustionTAC.Cfg.diff_on_2,GasTurbine.chambreCombustionTAC.Cfg.diff_on_1,GasTurbine.Sortie_fumees.diff_on_1,GasTurbine.chambreCombustionTAC.Ca.diff_on_2,GasTurbine.Entree_air.diff_on_2,GasTurbine.chambreCombustionTAC.Cws.diff_on_2,GasTurbine.Compresseur.Cs.diff_on_1,MelangeurPreTMP.Ce1.diff_on_2,DoubleDebitMP.Cs.diff_on_2,DoubleDebitMP.Cs.diff_on_1,vanne_entree_TurbineMP.C2.diff_on_1,MelangeurPreTMP.Cs.diff_on_1,TurbineMP.Cs.diff_on_1,MelangeurPreTMP.Ce3.diff_on_2,MelangeurPreTMP.Ce2.diff_on_2,MelangeurPreTMP.Ce3.diff_on_1,MelangeurPreTMP.Ce2.diff_on_1,VolumePreTHP.Cs3.diff_on_1,TurbineHP.Cs.diff_on_1,VolumePreTHP.Cs2.diff_on_1,VolumePreTHP.Cs1.diff_on_1,VolumePreTHP.Ce.diff_on_2,DoubleDebitHP.Cs.diff_on_2,VolumePreTHP.Cs2.diff_on_2,VolumePreTHP.Cs1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C1.diff_on_2,PompeAlimMP.C2.diff_on_2,perteChargeK8.C2.diff_on_2,VolumeAlimMPHP.Cs1.diff_on_1,perteChargeK8.C2.diff_on_1,PompeAlimMP.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C1.diff_on_2,Vanne_alimentationMPHP1.C1.diff_on_2,perteChargeK3.C2.diff_on_2,VolumeAlimMPHP.Cs2.diff_on_1,perteChargeK3.C2.diff_on_1,Vanne_alimentationMPHP1.C1.diff_on_1,VolumeECO_HP2_3.Cs.diff_on_1,VolumeECO_HP2_3.Ce3.diff_on_2,VolumeECO_HP2_3.Ce2.diff_on_2,VolumeECO_HP2_3.Ce1.diff_on_2,VolumeECO_HP2_3.Ce3.diff_on_1,VolumeECO_HP2_3.Ce2.diff_on_1,VolumeECO_HP1_2.Cs.diff_on_1,VolumeECO_HP1_2.Ce3.diff_on_2,VolumeECO_HP1_2.Ce2.diff_on_2,VolumeECO_HP1_2.Ce1.diff_on_2,VolumeECO_HP1_2.Ce3.diff_on_1,VolumeECO_HP1_2.Ce2.diff_on_1,DoubleDebitHP.Cs.diff_on_1,vanne_entree_TurbineHP.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C1.diff_on_2,lumpedStraightPipeK2.C1.diff_on_2,MelangeurHPMP.Cs2.diff_on_1,SurchauffeurMP2.Cws1.diff_on_1,Condenseur.Cv.diff_on_2,TurbineBP.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_2,MelangeurPostTMP1.Cs.diff_on_1,TurbineBP.Cs.diff_on_1,CapteurDebitVapCondenseur.C2.diff_on_1,MoitieDebitBP.Ce.diff_on_2,vanne_extraction.C2.diff_on_2,PompeAlimBP.C2.diff_on_2,Condenseur.Cl.diff_on_1,perteChargeK.C2.diff_on_1,PompeAlimBP.C2.diff_on_1,VolumeAlimMPHP.Ce1.diff_on_2,CapteurDebitEauBPsortie.C1.diff_on_2,BallonBP.Cs.diff_on_1,Vanne_alimentationMPHP.C2.diff_on_1,BallonBP.Ce1.diff_on_2,CapteurDebitEauBP.C1.diff_on_2,EconomiseurBP.TwoPhaseFlowPipe.C2.diff_on_1,BallonBP.Ce1.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurBP.C1.diff_on_2,BallonBP.Cv.diff_on_1,CapteurDebitVapBP.C2.diff_on_1,SurchauffeurMP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurMP.C1.diff_on_2,BallonMP.Cv.diff_on_1,CapteurDebitVapMP.C2.diff_on_1,BallonMP.Ce1.diff_on_2,CapteurDebitEauMP.C1.diff_on_2,EconomiseurMP.TwoPhaseFlowPipe.C2.diff_on_1,BallonMP.Ce1.diff_on_1,BallonHP.Ce1.diff_on_2,CapteurDebitEauHP.C1.diff_on_2,EconomiseurHP4.TwoPhaseFlowPipe.C2.diff_on_1,BallonHP.Ce1.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C1.diff_on_2,vanne_vapeurHP.C1.diff_on_2,BallonHP.Cv.diff_on_1,CapteurDebitVapHP.C2.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_2,DoubleDebitBP.Cs.diff_on_2,DoubleDebitBP.Cs.diff_on_1,MelangeurPostTMP1.Ce2.diff_on_1,DoubleDebitBP.Ce.diff_on_2,MoitieDebitBP.Cs.diff_on_1,VolumeAlimMPHP.Ce2.diff_on_2,VolumeAlimMPHP.Ce2.diff_on_1,EconomiseurBP.TwoPhaseFlowPipe.C1.diff_on_2,VolumeCond1.Cs.diff_on_2,VolumeCond1.Cs.diff_on_1,EconomiseurBP.Cws1.diff_on_1,VolumeCond1.Ce3.diff_on_2,VolumeCond1.Ce2.diff_on_2,VolumeCond1.Ce1.diff_on_2,VolumeCond1.Ce2.diff_on_1,VolumeCond1.Ce1.diff_on_1,MoitieDebitHP.Cs.diff_on_1,MoitieDebitHP.Ce.diff_on_2,VolumePreTHP.Cs3.diff_on_2,DoubleDebitMP.Ce.diff_on_2,DoubleDebitHP.Ce.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_2,MelangeurPostTMP1.Ce1.diff_on_2,MelangeurPreTMP.Cs.diff_on_2,MelangeurPostTMP1.Ce3.diff_on_1,EconomiseurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurBP.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurBP.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurBP.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurBP.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurBP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurBP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurBP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurBP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapBP.Cs.diff_on_1,VolumeEvapBP.Ce3.diff_on_2,VolumeEvapBP.Ce2.diff_on_2,VolumeEvapBP.Ce1.diff_on_2,BallonBP.Cd.diff_on_2,VolumeEvapBP.Ce3.diff_on_1,VolumeEvapBP.Ce2.diff_on_1,BallonBP.Cd.diff_on_1,VolumeEvapBP.Ce1.diff_on_1,BallonBP.Cm.diff_on_2,BallonBP.Ce3.diff_on_2,BallonBP.Ce2.diff_on_2,BallonBP.Ce3.diff_on_1,BallonBP.Ce2.diff_on_1,SurchauffeurMP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurMP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurMP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.diff_on_1,MelangeurHPMP.Cs1.diff_on_1,MelangeurHPMP.Ce2.diff_on_2,MelangeurHPMP.Ce1.diff_on_2,MelangeurHPMP.Cs1.diff_on_2,SurchauffeurMP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurMP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapMP.Cs.diff_on_1,VolumeEvapMP.Ce3.diff_on_2,VolumeEvapMP.Ce2.diff_on_2,VolumeEvapMP.Ce1.diff_on_2,GainChargeMP.C1.diff_on_2,VolumeEvapMP.Ce3.diff_on_1,VolumeEvapMP.Ce2.diff_on_1,BallonMP.Cd.diff_on_1,VolumeEvapMP.Ce1.diff_on_1,EvaporateurMP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurMP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurMP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurMP.ExchangerFlueGasesMetal.C2.diff_on_1,BallonMP.Cs.diff_on_1,BallonMP.Cm.diff_on_2,BallonMP.Ce3.diff_on_2,BallonMP.Ce2.diff_on_2,BallonMP.Cs.diff_on_2,BallonMP.Ce3.diff_on_1,BallonMP.Ce2.diff_on_1,SurchauffeurHP3.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP3.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP2.TwoPhaseFlowPipe.C1.diff_on_2,SurchauffeurHP2.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP1.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP2.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP2.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP2.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP2.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP3.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP3.TwoPhaseFlowPipe.C2.diff_on_1,EconomiseurHP3.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP3.ExchangerFlueGasesMetal.C2.diff_on_1,SurchauffeurHP1.TwoPhaseFlowPipe.C2.diff_on_1,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.diff_on_2,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.diff_on_1,EconomiseurHP4.TwoPhaseFlowPipe.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C1.diff_on_2,EconomiseurHP4.ExchangerFlueGasesMetal.C2.diff_on_1,EvaporateurHP.TwoPhaseFlowPipe.C1.diff_on_2,EvaporateurHP.TwoPhaseFlowPipe.C2.diff_on_1,EvaporateurHP.ExchangerFlueGasesMetal.C1.diff_on_2,EvaporateurHP.ExchangerFlueGasesMetal.C2.diff_on_1,VolumeEvapHP.Cs.diff_on_1,VolumeEvapHP.Ce3.diff_on_2,VolumeEvapHP.Ce2.diff_on_2,VolumeEvapHP.Ce1.diff_on_2,GainChargeHP.C1.diff_on_2,VolumeEvapHP.Ce3.diff_on_1,VolumeEvapHP.Ce2.diff_on_1,BallonHP.Cd.diff_on_1,VolumeEvapHP.Ce1.diff_on_1,BallonHP.Cs.diff_on_1,BallonHP.Cm.diff_on_2,BallonHP.Ce3.diff_on_2,BallonHP.Ce2.diff_on_2,BallonHP.Cs.diff_on_2,BallonHP.Ce3.diff_on_1,BallonHP.Ce2.diff_on_1) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (3714): * Single equations (assignments): 3658 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 34 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 7 * Torn equation systems: 13 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 7 systems {1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 1 system {(4,1,62.5%)} * Non-linear torn systems (#iteration vars, #inner vars): 12 systems {(1,15), (1,1), (1,15), (1,1), (1,5), (2,11), (305,2987), (1,1), (1,1), (1,1), (1,1), (12,26)} Notification: Performance of prepare postOptimizeDAE: time 0.09362/25.51, allocations: 12.89 MB / 6.881 GB, free: 405.5 MB / 1.076 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.03737/25.55, allocations: 4.264 MB / 6.885 GB, free: 405.5 MB / 1.076 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 1.11/26.66, allocations: 168.2 MB / 7.049 GB, free: 441.7 MB / 1.076 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.5207/27.18, allocations: 147.8 MB / 7.194 GB, free: 411.4 MB / 1.076 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0003703/27.18, allocations: 19.44 kB / 7.194 GB, free: 411.4 MB / 1.076 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.002333/27.19, allocations: 310.5 kB / 7.194 GB, free: 411.4 MB / 1.076 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 1.348/28.53, allocations: 276.8 MB / 7.464 GB, free: 424.9 MB / 1.076 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001627/28.54, allocations: 137.5 kB / 7.464 GB, free: 424.9 MB / 1.076 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.07418/28.61, allocations: 13.23 MB / 7.477 GB, free: 424.5 MB / 1.076 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.1338/28.74, allocations: 42.41 MB / 7.519 GB, free: 413.3 MB / 1.076 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.029/28.77, allocations: 2.09 MB / 7.521 GB, free: 411.7 MB / 1.076 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.9691/29.74, allocations: 301 MB / 7.815 GB, free: 326.6 MB / 1.076 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.458e-05/29.74, allocations: 39.05 kB / 7.815 GB, free: 326.6 MB / 1.076 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 1.237/30.98, allocations: 228.6 MB / 8.038 GB, free: 402.7 MB / 1.076 GB Notification: Performance of postOpt removeConstants (simulation): time 0.06357/31.04, allocations: 14.29 MB / 8.052 GB, free: 398.3 MB / 1.076 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.03376/31.08, allocations: 1.269 MB / 8.053 GB, free: 397.4 MB / 1.076 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.08547/31.16, allocations: 6.396 MB / 8.059 GB, free: 396.6 MB / 1.076 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.03611/31.2, allocations: 4.687 MB / 8.064 GB, free: 395.9 MB / 1.076 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.02677/31.22, allocations: 2.277 MB / 8.066 GB, free: 395.5 MB / 1.076 GB Notification: Performance of sorting global known variables: time 0.03166/31.26, allocations: 12.7 MB / 8.079 GB, free: 391.3 MB / 1.076 GB Notification: Performance of sort global known variables: time 1.91e-07/31.26, allocations: 0 / 8.079 GB, free: 391.3 MB / 1.076 GB Notification: Performance of remove unused functions: time 0.1316/31.39, allocations: 19.52 MB / 8.098 GB, free: 389.2 MB / 1.076 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 91 * Number of states: 249 (BallonHP.P,BallonHP.hl,BallonHP.hv,BallonHP.Tp,BallonHP.Vv,VolumeEvapHP.h,EvaporateurHP.ExchangerWall.Tp[1],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[4],EconomiseurHP4.ExchangerWall.Tp[1],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.ExchangerWall.Tp[1],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP3.ExchangerWall.Tp[1],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[4],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.ExchangerWall.Tp[1],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[1],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[1],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[4],BallonMP.P,BallonMP.hl,BallonMP.hv,BallonMP.Tp,BallonMP.Vv,EvaporateurMP.ExchangerWall.Tp[1],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[4],VolumeEvapMP.h,EconomiseurMP.ExchangerWall.Tp[1],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.ExchangerWall.Tp[1],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[4],MelangeurHPMP.h,SurchauffeurMP2.ExchangerWall.Tp[1],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[1],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[4],BallonBP.P,BallonBP.hl,BallonBP.hv,BallonBP.Tp,BallonBP.Vv,VolumeEvapBP.h,EvaporateurBP.ExchangerWall.Tp[1],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.ExchangerWall.Tp[1],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.ExchangerWall.Tp[1],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[4],MelangeurPostTMP1.h,Condenseur.P,Condenseur.hl,Condenseur.hv,Condenseur.Vv,VolumeCond1.h,VolumeAlimMPHP.h,regulation_Niveau_HP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_3.x,VolumeECO_HP1_2.P,VolumeECO_HP1_2.h,VolumeECO_HP2_3.P,VolumeECO_HP2_3.h,VolumePreTHP.P,VolumePreTHP.h,MelangeurPreTMP.P,MelangeurPreTMP.h) * Number of discrete variables: 17 ($whenCondition1,regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal,perteChargeK2.C2.diff_on_1,vanne_extraction.C2.diff_on_1,CapteurDebitEauCondenseur.C1.diff_on_2,perteChargeK.C2.diff_on_2,Vanne_alimentationMPHP1.C2.diff_on_1,VolumeAlimMPHP.Cs2.diff_on_2,EconomiseurMP.Cws1.diff_on_1,VolumeAlimMPHP.Cs1.diff_on_2) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (5341): * Single equations (assignments): 4929 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 256 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 6 * Torn equation systems: 143 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 2 systems {1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 55 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,2,100.0%), (1,2,100.0%), (1,2,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 88 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,5), (1,3), (2,8), (1,5), (1,3), (2,8), (1,5), (1,5), (1,3), (1,3), (1,4), (1,4), (1,4), (1,5), (1,3), (5,16), (48,432), (12,26), (1,5), (1,2), (1,2), (1,5), (4,18), (1,3), (3,9)} Notification: Performance of Backend phase and start with SimCode phase: time 0.0473/31.43, allocations: 5.924 MB / 8.103 GB, free: 387.7 MB / 1.076 GB Notification: Performance of simCode: created initialization part: time 0.9121/32.35, allocations: 168.3 MB / 8.268 GB, free: 389.1 MB / 1.076 GB Notification: Performance of simCode: created event and clocks part: time 3.772e-05/32.35, allocations: 7.562 kB / 8.268 GB, free: 389.1 MB / 1.076 GB Notification: Performance of simCode: created simulation system equations: time 0.2486/32.6, allocations: 89.52 MB / 8.355 GB, free: 370.8 MB / 1.076 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.1719/32.77, allocations: 16.39 MB / 8.371 GB, free: 366.5 MB / 1.076 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 1.569/34.34, allocations: 187.7 MB / 8.555 GB, free: 391.9 MB / 1.076 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.07416/34.41, allocations: 29.58 MB / 8.584 GB, free: 389.1 MB / 1.076 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.04194/34.45, allocations: 4.251 MB / 8.588 GB, free: 389.1 MB / 1.076 GB Notification: Performance of SimCode: time 2.264e-06/34.45, allocations: 0 / 8.588 GB, free: 389.1 MB / 1.076 GB Notification: Performance of Templates: time 52.06/86.51, allocations: 19.34 GB / 27.93 GB, free: 297.9 MB / 1.076 GB " [Timeout remaining time 573] make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.makefile [Timeout 660] make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/include/omc/sundials" "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50CalcHelperMain.o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50CalcHelperMain.cpp In file included from OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50CalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50AlgLoopMain.cpp:195: ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:93:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp3234.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:94:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp3234.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:95:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp3234.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:96:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp3234.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:97:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp3234.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:98:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_pt_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_pt_ = get<0>(tmp3234.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:99:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cv_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_lsat2_P_cv_ = get<0>(tmp3234.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:100:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_P_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_P_ = get<1>(tmp3234.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:101:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_T_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_T_ = get<1>(tmp3234.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:102:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_rho_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_rho_ = get<1>(tmp3234.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:103:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_h_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_h_ = get<1>(tmp3234.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:104:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cp_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cp_ = get<1>(tmp3234.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:105:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_pt_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_pt_ = get<1>(tmp3234.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:106:3: error: use of undeclared identifier '_SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cv_' _SurchauffeurMP2_P_TwoPhaseFlowPipe_P_vsat2_P_cv_ = get<1>(tmp3234.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:112:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp3235.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:113:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp3235.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:114:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp3235.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:115:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp3235.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50Algloop12609.cpp:116:3: error: use of undeclared identifier '_SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _SurchauffeurMP3_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp3235.data).cp_; ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. make: *** [: OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50CalcHelperMain.o] Error 1 [Calling os._exit(0), Time elapsed: 93.61955094896257] Failed to read output from testmodel.py, exit status != 0: 86.66510151396506 86.673102683 81.111831193 Calling exit ...