Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8006/0.8006, allocations: 152.6 MB / 169.6 MB, free: 14.91 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant") translateModel(ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.000468/0.000468, allocations: 24.92 kB / 245.7 MB, free: 15.55 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.05707/0.05754, allocations: 33.05 MB / 278.7 MB, free: 0.5703 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant): time 1.688/1.745, allocations: 383.7 MB / 0.6469 GB, free: 15.67 MB / 0.5294 GB Notification: Performance of NFInst.instExpressions: time 0.5329/2.278, allocations: 224.9 MB / 0.8665 GB, free: 7.113 MB / 0.6387 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01479/2.293, allocations: 175.8 kB / 0.8667 GB, free: 6.941 MB / 0.6387 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceQ.mo:24:3-25:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:89:3-90:45:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:91:3-92:46:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:99:3-100:48:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:101:3-102:43:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:69:3-71:37:writable] Warning: Connector Ec is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:72:3-74:42:writable] Warning: Connector Ef is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:75:3-77:37:writable] Warning: Connector Sf is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:78:3-80:36:writable] Warning: Connector Sc is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:28:3-30:67:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:31:3-33:68:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:34:3-36:67:writable] Warning: Connector Ce4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:37:3-39:74:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:40:3-42:73:writable] Warning: Connector Cs4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:43:3-45:72:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:46:3-48:73:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:49:3-51:74:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:28:3-30:67:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:31:3-33:68:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:34:3-36:67:writable] Warning: Connector Ce4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:37:3-39:74:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:40:3-42:73:writable] Warning: Connector Cs4 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:43:3-45:72:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:46:3-48:73:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeI.mo:49:3-51:74:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:69:3-71:37:writable] Warning: Connector Ec is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:72:3-74:42:writable] Warning: Connector Ef is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:75:3-77:37:writable] Warning: Connector Sf is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/StaticWaterWaterExchangerDTorWorEff.mo:78:3-80:36:writable] Warning: Connector Sc is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorT.mo:28:3-30:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorT.mo:31:3-33:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:116:3-118:24:writable] Warning: Connector Cfuel is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:119:3-121:16:writable] Warning: Connector Ca is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:122:3-123:83:writable] Warning: Connector Cfg is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GenericCombustion1D.mo:124:3-126:17:writable] Warning: Connector Cws is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:115:3-116:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicOnePhaseFlowPipe.mo:117:3-118:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Splitter2.mo:24:3-26:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Splitter2.mo:27:3-28:82:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Splitter2.mo:29:3-31:17:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/InvSingularPressureLoss.mo:19:3-21:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/InvSingularPressureLoss.mo:22:3-24:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:30:3-31:83:writable] Warning: Connector Sc is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:32:3-34:16:writable] Warning: Connector Ec is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:35:3-37:16:writable] Warning: Connector Ef is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticFluegasesFluegasesExchangerKS.mo:38:3-39:83:writable] Warning: Connector Sf is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourcePQ.mo:29:3-30:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/BoundaryConditions/FuelSourcePQ.mo:21:3-22:65:writable] Warning: Connector C is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/CheckValve.mo:38:3-39:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/CheckValve.mo:40:3-41:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:65:3-67:38:writable] Warning: Connector Ee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:68:3-70:36:writable] Warning: Connector Se is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:71:3-73:37:writable] Warning: Connector Ep is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:74:3-76:38:writable] Warning: Connector Sp is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/NTUWaterHeating.mo:77:3-79:36:writable] Warning: Connector Ev is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:6:3-8:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/LoopBreakers/LoopBreakerP.mo:9:3-10:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:25:3-27:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:28:3-29:52:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01383/2.307, allocations: 4.216 MB / 0.8708 GB, free: 2.738 MB / 0.6387 GB Notification: Performance of NFTyping.typeBindings: time 0.03398/2.341, allocations: 11.98 MB / 0.8825 GB, free: 6.68 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.06075/2.401, allocations: 24.03 MB / 0.906 GB, free: 14.71 MB / 0.6856 GB Notification: Performance of NFFlatten.flatten: time 0.06739/2.469, allocations: 54.53 MB / 0.9592 GB, free: 8.012 MB / 0.7325 GB Notification: Performance of NFFlatten.resolveConnections: time 0.02594/2.495, allocations: 15.72 MB / 0.9746 GB, free: 8.145 MB / 0.7481 GB Notification: Performance of NFEvalConstants.evaluate: time 0.03532/2.53, allocations: 19.01 MB / 0.9932 GB, free: 5.082 MB / 0.7637 GB Notification: Performance of NFSimplifyModel.simplify: time 0.6626/3.193, allocations: 19.53 MB / 1.012 GB, free: 57.12 MB / 0.7638 GB Notification: Performance of NFPackage.collectConstants: time 0.01569/3.208, allocations: 3.529 MB / 1.016 GB, free: 57.12 MB / 0.7638 GB Notification: Performance of NFFlatten.collectFunctions: time 0.06059/3.269, allocations: 32.38 MB / 1.047 GB, free: 57.12 MB / 0.7638 GB Notification: Performance of NFScalarize.scalarize: time 0.01723/3.286, allocations: 10.01 MB / 1.057 GB, free: 57.12 MB / 0.7638 GB Notification: Performance of NFVerifyModel.verify: time 0.03478/3.321, allocations: 17.8 MB / 1.074 GB, free: 53.59 MB / 0.7638 GB Notification: Performance of NFConvertDAE.convert: time 0.07363/3.395, allocations: 56.52 MB / 1.13 GB, free: 22.66 MB / 0.7638 GB Notification: Performance of FrontEnd - DAE generated: time 5.621e-06/3.395, allocations: 0 / 1.13 GB, free: 22.66 MB / 0.7638 GB Notification: Performance of FrontEnd: time 1.362e-06/3.395, allocations: 0.8125 kB / 1.13 GB, free: 22.66 MB / 0.7638 GB Notification: Performance of Transformations before backend: time 0.001453/3.396, allocations: 0 / 1.13 GB, free: 22.66 MB / 0.7638 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 8847 * Number of variables: 8847 Notification: Performance of Generate backend data structure: time 0.1224/3.518, allocations: 38.22 MB / 1.167 GB, free: 1.996 MB / 0.7794 GB Notification: Performance of prepare preOptimizeDAE: time 4.391e-05/3.518, allocations: 12.03 kB / 1.167 GB, free: 1.984 MB / 0.7794 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.01266/3.531, allocations: 3.284 MB / 1.17 GB, free: 14.68 MB / 0.795 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.02521/3.556, allocations: 10.41 MB / 1.18 GB, free: 5.125 MB / 0.795 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.009831/3.566, allocations: 7.013 MB / 1.187 GB, free: 13.1 MB / 0.8107 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.009773/3.576, allocations: 2.107 MB / 1.189 GB, free: 11 MB / 0.8107 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.1226/3.699, allocations: 44.56 MB / 1.233 GB, free: 13.3 MB / 0.8575 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0009458/3.699, allocations: 60.19 kB / 1.233 GB, free: 13.28 MB / 0.8575 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.008794/3.708, allocations: 0.8601 MB / 1.234 GB, free: 12.42 MB / 0.8575 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001585/3.71, allocations: 1.296 MB / 1.235 GB, free: 11.12 MB / 0.8575 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.1281/3.838, allocations: 47.05 MB / 1.281 GB, free: 12.34 MB / 0.9044 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.5122/4.35, allocations: 193.8 MB / 1.47 GB, free: 378.7 MB / 0.9513 GB Notification: Performance of preOpt comSubExp (simulation): time 0.0847/4.435, allocations: 36.11 MB / 1.505 GB, free: 359.6 MB / 0.9513 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.05659/4.491, allocations: 26.65 MB / 1.531 GB, free: 345.2 MB / 0.9513 GB Notification: Performance of preOpt evalFunc (simulation): time 0.3251/4.816, allocations: 186.6 MB / 1.714 GB, free: 143.4 MB / 0.9513 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.06601/4.882, allocations: 31.58 MB / 1.745 GB, free: 111.7 MB / 0.9513 GB Notification: Performance of pre-optimization done (n=5820): time 5.231e-05/4.883, allocations: 4 kB / 1.745 GB, free: 111.7 MB / 0.9513 GB Notification: Performance of matching and sorting (n=5830): time 1.206/6.088, allocations: 273.3 MB / 2.011 GB, free: 396.5 MB / 0.9513 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.00035/6.089, allocations: 1.057 MB / 2.013 GB, free: 395.3 MB / 0.9513 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.00974/6.098, allocations: 6.966 MB / 2.019 GB, free: 388.3 MB / 0.9513 GB Notification: Performance of collectPreVariables (initialization): time 0.006777/6.105, allocations: 429.7 kB / 2.02 GB, free: 387.9 MB / 0.9513 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/CheckValve.mo:7:3-8:32:writable] Warning: The parameter CheckValve.k has fixed = false and a binding equation CheckValve.k = 100.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:3:3-3:53:writable] Warning: The parameter singularPressureLoss_Eco.K has fixed = false and a binding equation singularPressureLoss_Eco.K = 3867.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP2.K has fixed = false and a binding equation lumpedStraightPipe_HP2.K = 1e-4, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:3:3-3:53:writable] Warning: The parameter singularPressureLoss_RBT.K has fixed = false and a binding equation singularPressureLoss_RBT.K = 34.39, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/SingularPressureLoss.mo:3:3-3:53:writable] Warning: The parameter singularPressureLoss_SBT.K has fixed = false and a binding equation singularPressureLoss_SBT.K = 910.878, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:3:3-4:43:writable] Warning: The parameter controlValveIP.Cvmax has fixed = false and a binding equation controlValveIP.Cvmax = 8005.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:3:3-4:43:writable] Warning: The parameter controlValveHP.Cvmax has fixed = false and a binding equation controlValveHP.Cvmax = 8005.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_HP1.Cst has fixed = false and a binding equation Turbine_HP1.Cst = 279474.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP_IP.K has fixed = false and a binding equation lumpedStraightPipe_HP_IP.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP.K has fixed = false and a binding equation lumpedStraightPipe_HP.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_HP1.K has fixed = false and a binding equation lumpedStraightPipe_HP1.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:22:3-23:69:writable] Warning: The parameter staticCentrifugalPump1.a1 has fixed = false and a binding equation staticCentrifugalPump1.a1 = -3050.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_IP1.K has fixed = false and a binding equation lumpedStraightPipe_IP1.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:22:3-23:69:writable] Warning: The parameter staticCentrifugalPump.a1 has fixed = false and a binding equation staticCentrifugalPump.a1 = -390.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_LP3.K has fixed = false and a binding equation lumpedStraightPipe_LP3.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_LP2.K has fixed = false and a binding equation lumpedStraightPipe_LP2.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_LP1.K has fixed = false and a binding equation lumpedStraightPipe_LP1.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:3:3-3:59:writable] Warning: The parameter lumpedStraightPipe_IP3.K has fixed = false and a binding equation lumpedStraightPipe_IP3.K = 10.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Echappement.Cst has fixed = false and a binding equation Echappement.Cst = 14.7, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_LP3.Cst has fixed = false and a binding equation Turbine_LP3.Cst = 59.4076, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_IP3.Cst has fixed = false and a binding equation Turbine_IP3.Cst = 34076.9, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_LP1.Cst has fixed = false and a binding equation Turbine_LP1.Cst = 4485.97, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_IP1.Cst has fixed = false and a binding equation Turbine_IP1.Cst = 102478.0, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_LP2.Cst has fixed = false and a binding equation Turbine_LP2.Cst = 1215.75, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_IP2.Cst has fixed = false and a binding equation Turbine_IP2.Cst = 53802.6, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:3:3-3:58:writable] Warning: The parameter Turbine_HP.Cst has fixed = false and a binding equation Turbine_HP.Cst = 2.00537e6, which is probably redundant. Setting fixed = false usually means there is an additional initial equation to determine the parameter value. The binding was ignored by old Modelica tools, but this is not according to the Modelica specification. Please remove the parameter binding, or bind the parameter to another parameter with fixed = false and no binding. Notification: Performance of collectInitialEqns (initialization): time 0.003873/6.109, allocations: 6.465 MB / 2.026 GB, free: 381.5 MB / 0.9513 GB Notification: Performance of collectInitialBindings (initialization): time 0.01781/6.127, allocations: 20.08 MB / 2.046 GB, free: 361.7 MB / 0.9513 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.02699/6.154, allocations: 6.51 MB / 2.052 GB, free: 355.1 MB / 0.9513 GB Notification: Performance of setup shared object (initialization): time 4.649e-05/6.154, allocations: 315.1 kB / 2.052 GB, free: 354.8 MB / 0.9513 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.05575/6.21, allocations: 24.29 MB / 2.076 GB, free: 330.5 MB / 0.9513 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.05985/6.27, allocations: 30.07 MB / 2.105 GB, free: 298.9 MB / 0.9513 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 2/8.269, allocations: 0.621 GB / 2.726 GB, free: 377.5 MB / 0.9513 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001601/8.269, allocations: 30.97 kB / 2.726 GB, free: 377.5 MB / 0.9513 GB Notification: Performance of matching and sorting (n=6510) (initialization): time 0.2275/8.497, allocations: 81.46 MB / 2.806 GB, free: 344.7 MB / 0.9513 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001155/8.497, allocations: 107.4 kB / 2.806 GB, free: 344.6 MB / 0.9513 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.000397/8.497, allocations: 164 kB / 2.806 GB, free: 344.4 MB / 0.9513 GB Notification: Performance of postOpt tearingSystem (initialization): time 1.587/10.08, allocations: 0.8332 GB / 3.639 GB, free: 187.7 MB / 0.9513 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.008488/10.09, allocations: 1.788 MB / 3.641 GB, free: 186.4 MB / 0.9513 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02086/10.11, allocations: 14.48 MB / 3.655 GB, free: 173.3 MB / 0.9513 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.03321/10.15, allocations: 2.805 MB / 3.658 GB, free: 171.8 MB / 0.9513 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01064/10.16, allocations: 1.242 MB / 3.659 GB, free: 171 MB / 0.9513 GB Warning: Assuming fixed start value for the following 4 variables: TemperatureControl.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Level_Condenser.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Level_Condenser.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Pump_VelocityControl.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 30 initial equations are redundant, so they are removed from the initialization system: $DER.splitter_TurbineIP2.P = 0.0 $DER.splitter_Turbine_HP.P = 0.0 $DER.Boiler_walls.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.RMT_RHT.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SBT.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.RBT.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.RBT.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.Economiseur.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SMT_SHT.TwoPhaseFlowPipe.Q[3] = 0.0 $DER.SMT_SHT.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.TemperatureControl.pIsat.Integrateur1.x = 0.0 $DER.volume_HP2.h = 0.0 $DER.volume_HP1Vap1.P = 0.0 $DER.volume_HP21.P = 0.0 $DER.volume_HP21.h = 0.0 $DER.pT1_2.x = 0.0 CheckValve.Q = $START.CheckValve.Q SMT_SHT.TwoPhaseFlowPipe.P[5] = $START.SMT_SHT.TwoPhaseFlowPipe.P[5] RMT_RHT.TwoPhaseFlowPipe.P[5] = $START.RMT_RHT.TwoPhaseFlowPipe.P[5] lumpedStraightPipe_HP_IP.Q = $START.lumpedStraightPipe_HP_IP.Q lumpedStraightPipe_LP3.Q = $START.lumpedStraightPipe_LP3.Q splitter_TurbineLP3.P = $START.splitter_TurbineLP3.P lumpedStraightPipe_LP2.Q = $START.lumpedStraightPipe_LP2.Q splitter_TurbineLP2.P = $START.splitter_TurbineLP2.P splitter_TurbineLP1.P = $START.splitter_TurbineLP1.P splitter_TurbineIP3.P = $START.splitter_TurbineIP3.P lumpedStraightPipe_IP3.Q = $START.lumpedStraightPipe_IP3.Q splitter_TurbineIP2.P = $START.splitter_TurbineIP2.P splitter_TurbineIP1.P = $START.splitter_TurbineIP1.P Turbine_HP.Pe = $START.Turbine_HP.Pe. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 493 * Number of states: 0 () * Number of discrete variables: 348 ($PRE.TemperatureControl.pIsat.Integrateur1.x0,TemperatureControl.pIsat.Integrateur1.x0,$PRE.regulation_Level_Condenser.pIsat.Integrateur1.x0,regulation_Level_Condenser.pIsat.Integrateur1.x0,$PRE.regulation_Level_Condenser.pIsat1.Integrateur1.x0,regulation_Level_Condenser.pIsat1.Integrateur1.x0,$PRE.Pump_VelocityControl.pIsat.Integrateur1.x0,Pump_VelocityControl.pIsat.Integrateur1.x0,$PRE.CheckValve.touvert,$whenCondition2,$PRE.CheckValve.tferme,$whenCondition1,Pump_VelocityControl.pIsat.Integrateur1.reset.signal,regulation_Level_Condenser.pIsat.Integrateur1.reset.signal,TemperatureControl.pIsat.Integrateur1.reset.signal,CheckValve.tferme,CheckValve.touvert,CheckValve.ouvert,$PRE.CheckValve.ouvert,regulation_Level_Condenser.echelon.yL.signal,regulation_Level_Condenser.edge.yL.signal,regulation_Level_Condenser.edge.uL.signal,$PRE.regulation_Level_Condenser.edge.uL.signal,$whenCondition3,volume_HP22.Cs2.b,volume_HP22.Cs1.b,volume_HP22.Ce2.a,volume_HP22.Ce1.a,volume_HP21.Cs2.b,volume_HP21.Cs1.b,volume_HP21.Ce2.a,volume_HP21.Ce1.a,singularPressureLoss7.C2.b,singularPressureLoss7.C1.a,singularPressureLoss6.C2.b,singularPressureLoss6.C1.a,singularPressureLoss5.C2.b,singularPressureLoss5.C1.a,singularPressureLoss4.C2.b,singularPressureLoss4.C1.a,singularPressureLoss3.C2.b,singularPressureLoss3.C1.a,singularPressureLoss2.C2.b,singularPressureLoss2.C1.a,singularPressureLoss1.C2.b,singularPressureLoss1.C1.a,volume_HP1Vap1.Cs2.b,volume_HP1Vap1.Cs1.b,volume_HP1Vap1.Ce2.a,volume_HP1Vap1.Ce1.a,volume_HP1Vap.Cs2.b,volume_HP1Vap.Cs1.b,volume_HP1Vap.Ce2.a,volume_HP1Vap.Ce1.a,volume_HP3.Cs2.b,volume_HP3.Cs1.b,volume_HP3.Ce2.a,volume_HP3.Ce1.a,volume_HP2.Cs2.b,volume_HP2.Cs1.b,volume_HP2.Ce2.a,volume_HP2.Ce1.a,ReheaterHP2_1.Ev.a,ReheaterHP2_1.Sp.b,ReheaterHP2_1.Ep.a,ReheaterHP2_1.Se.b,ReheaterHP2_1.Ee.a,ReheaterHP1_1.Ev.a,ReheaterHP1_1.Sp.b,ReheaterHP1_1.Ep.a,ReheaterHP1_1.Se.b,ReheaterHP1_1.Ee.a,volume_HP1.Cs2.b,volume_HP1.Cs1.b,volume_HP1.Ce2.a,volume_HP1.Ce1.a,sensorQ.C2.b,sensorQ.C1.a,CheckValve.C2.b,CheckValve.C1.a,singularPressureLoss_Eco.C2.b,singularPressureLoss_Eco.C1.a,splitter_condenser.Cs2.b,splitter_condenser.Cs1.b,splitter_condenser.Ce2.a,splitter_condenser.Ce1.a,lumpedStraightPipe_HP2.C2.b,lumpedStraightPipe_HP2.C1.a,lumpedStraightPipe_Condenser1.C2.b,lumpedStraightPipe_Condenser1.C1.a,controlValve_Condenser.C2.b,controlValve_Condenser.C1.a,lumpedStraightPipe_Low.C2.b,lumpedStraightPipe_Low.C1.a,Sensor_Qvap_Cond2.C2.b,Sensor_Qvap_Cond2.C1.a,Sensor_Qvap_Cond.C2.b,Sensor_Qvap_Cond.C1.a,loopBreakerP_Cond.C2.b,loopBreakerP_Cond.C1.a,loopBreakerP_ReDrum.C2.b,loopBreakerP_ReDrum.C1.a,loopBreakerP_Drum_2.C2.b,loopBreakerP_Drum_2.C1.a,controlValveEco.C2.b,controlValveEco.C1.a,fuelSourcePQ.C.b,sourceQ.C.b,volumeA.Cs2.b,volumeA.Cs1.b,volumeA.Ce2.a,volumeA.Ce1.a,volumeA1.Cs2.b,volumeA1.Cs1.b,volumeA1.Ce2.a,volumeA1.Ce1.a,AirPreheater.Ce2.a,AirPreheater.Cs1.b,AirPreheater.Cs2.b,AirPreheater.Ce1.a,sourceAir.C.b,RA.Sf.b,RA.Ef.a,RA.Ec.a,RA.Sc.b,mixer2_1.Ce1.a,mixer2_1.Cs.b,mixer2_1.Ce2.a,singularPressureLoss.C2.b,singularPressureLoss.C1.a,SMT_SHT.TwoPhaseFlowPipe.C2.b,SMT_SHT.TwoPhaseFlowPipe.C1.a,SMT_SHT.ExchangerFlueGasesMetal.C2.b,SMT_SHT.ExchangerFlueGasesMetal.C1.a,Economiseur.TwoPhaseFlowPipe.C2.b,Economiseur.TwoPhaseFlowPipe.C1.a,Economiseur.ExchangerFlueGasesMetal.C2.b,Economiseur.ExchangerFlueGasesMetal.C1.a,singularPressureLoss_RBT.C2.b,singularPressureLoss_RBT.C1.a,RBT.TwoPhaseFlowPipe.C2.b,RBT.TwoPhaseFlowPipe.C1.a,RBT.ExchangerFlueGasesMetal.C2.b,RBT.ExchangerFlueGasesMetal.C1.a,singularPressureLoss_SBT.C2.b,singularPressureLoss_SBT.C1.a,SBT.TwoPhaseFlowPipe.C2.b,SBT.TwoPhaseFlowPipe.C1.a,SBT.ExchangerFlueGasesMetal.C2.b,SBT.ExchangerFlueGasesMetal.C1.a,RMT_RHT.TwoPhaseFlowPipe.C2.b,RMT_RHT.TwoPhaseFlowPipe.C1.a,RMT_RHT.ExchangerFlueGasesMetal.C2.b,RMT_RHT.ExchangerFlueGasesMetal.C1.a,puitsFumeesPTQXA1.C.a,Boiler_walls.TwoPhaseFlowPipe.C2.b,Boiler_walls.TwoPhaseFlowPipe.C1.a,Boiler_walls.ExchangerFlueGasesMetal.C2.b,Boiler_walls.ExchangerFlueGasesMetal.C1.a,splitter2_1.Cs2.b,splitter2_1.Cs1.b,splitter2_1.Ce.a,Wall_screen.C2.b,Wall_screen.C1.a,genericCombustion.Cws.a,genericCombustion.Cfg.b,genericCombustion.Ca.a,genericCombustion.Cfuel.a,controlValveIP.C2.b,controlValveIP.C1.a,controlValveHP.C2.b,controlValveHP.C1.a,sensorT.C2.b,sensorT.C1.a,splitter_Turbine_HP.Cs3.b,splitter_Turbine_HP.Cs2.b,splitter_Turbine_HP.Cs1.b,splitter_Turbine_HP.Ce.a,Turbine_HP1.Cs.b,Turbine_HP1.Ce.a,lumpedStraightPipe_HP_IP.C2.b,lumpedStraightPipe_HP_IP.C1.a,lumpedStraightPipe_HP.C2.b,lumpedStraightPipe_HP.C1.a,Desuperheater.Sc.b,Desuperheater.Sf.b,Desuperheater.Ef.a,Desuperheater.Ec.a,ReheaterHP1.Ev.a,ReheaterHP1.Sp.b,ReheaterHP1.Ep.a,ReheaterHP1.Se.b,ReheaterHP1.Ee.a,lumpedStraightPipe_HP1.C2.b,lumpedStraightPipe_HP1.C1.a,ReheaterHP2.Ev.a,ReheaterHP2.Sp.b,ReheaterHP2.Ep.a,ReheaterHP2.Se.b,ReheaterHP2.Ee.a,lumpedStraightPipe_Desu.C2.b,lumpedStraightPipe_Desu.C1.a,ReheaterHP3.Ev.a,ReheaterHP3.Sp.b,ReheaterHP3.Ep.a,ReheaterHP3.Se.b,ReheaterHP3.Ee.a,staticCentrifugalPump1.C2.b,staticCentrifugalPump1.C1.a,Drum_2.Cs3.b,Drum_2.Cs2.b,Drum_2.Cs1.b,Drum_2.Cs4.b,Drum_2.Ce1.a,Drum_2.Ce4.a,Drum_2.Ce3.a,Drum_2.Ce2.a,lumpedStraightPipe_IP1.C2.b,lumpedStraightPipe_IP1.C1.a,Drum_1.Cs3.b,Drum_1.Cs2.b,Drum_1.Cs1.b,Drum_1.Cs4.b,Drum_1.Ce1.a,Drum_1.Ce4.a,Drum_1.Ce3.a,Drum_1.Ce2.a,pipePressureLoss_LP3_Drum.C2.b,pipePressureLoss_LP3_Drum.C1.a,ReheaterIP.Ev.a,ReheaterIP.Sp.b,ReheaterIP.Ep.a,ReheaterIP.Se.b,ReheaterIP.Ee.a,ReheaterLP1.Ev.a,ReheaterLP1.Sp.b,ReheaterLP1.Ep.a,ReheaterLP1.Se.b,ReheaterLP1.Ee.a,ReheaterLP2.Ev.a,ReheaterLP2.Sp.b,ReheaterLP2.Ep.a,ReheaterLP2.Se.b,ReheaterLP2.Ee.a,ReheaterLP3.Ev.a,ReheaterLP3.Sp.b,ReheaterLP3.Ep.a,ReheaterLP3.Se.b,ReheaterLP3.Ee.a,ReDrum.Sc.b,ReDrum.Sf.b,ReDrum.Ef.a,ReDrum.Ec.a,staticCentrifugalPump.C2.b,staticCentrifugalPump.C1.a,Condenser.Cse.b,Condenser.Cee.a,Condenser.Cl.b,Condenser.Cv.a,lumpedStraightPipe_Condenser2.C2.b,lumpedStraightPipe_Condenser2.C1.a,SourceCaloporteur.C.b,PuitsCaloporteur.C.a,lumpedStraightPipe_LP3.C2.b,lumpedStraightPipe_LP3.C1.a,splitter_TurbineLP3.Cs2.b,splitter_TurbineLP3.Cs1.b,splitter_TurbineLP3.Ce2.a,splitter_TurbineLP3.Ce1.a,lumpedStraightPipe_LP2.C2.b,lumpedStraightPipe_LP2.C1.a,splitter_TurbineLP2.Cs2.b,splitter_TurbineLP2.Cs1.b,splitter_TurbineLP2.Ce2.a,splitter_TurbineLP2.Ce1.a,lumpedStraightPipe_LP1.C2.b,lumpedStraightPipe_LP1.C1.a,splitter_TurbineLP1.Cs2.b,splitter_TurbineLP1.Cs1.b,splitter_TurbineLP1.Ce2.a,splitter_TurbineLP1.Ce1.a,splitter_TurbineIP3.Cs2.b,splitter_TurbineIP3.Cs1.b,splitter_TurbineIP3.Ce2.a,splitter_TurbineIP3.Ce1.a,lumpedStraightPipe_IP3.C2.b,lumpedStraightPipe_IP3.C1.a,splitter_TurbineIP2.Cs2.b,splitter_TurbineIP2.Cs1.b,splitter_TurbineIP2.Ce2.a,splitter_TurbineIP2.Ce1.a,splitter_TurbineIP1.Cs2.b,splitter_TurbineIP1.Cs1.b,splitter_TurbineIP1.Ce2.a,splitter_TurbineIP1.Ce1.a,Echappement.Cs.b,Echappement.Ce.a,Turbine_LP3.Cs.b,Turbine_LP3.Ce.a,Turbine_IP3.Cs.b,Turbine_IP3.Ce.a,Turbine_LP1.Cs.b,Turbine_LP1.Ce.a,Turbine_IP1.Cs.b,Turbine_IP1.Ce.a,Turbine_LP2.Cs.b,Turbine_LP2.Ce.a,Turbine_IP2.Cs.b,Turbine_IP2.Ce.a,splitter_Turbine_HP1.Cs3.b,splitter_Turbine_HP1.Cs2.b,splitter_Turbine_HP1.Cs1.b,splitter_Turbine_HP1.Ce.a,Turbine_HP.Cs.b,Turbine_HP.Ce.a,volume_HP22.Cs2.a,volume_HP22.Ce2.b,volume_HP21.Cs2.a,volume_HP21.Ce2.b,volume_HP1Vap1.Ce2.b,volume_HP1Vap.Ce2.b,volume_HP3.Cs1.a,volume_HP2.Ce1.b,ReheaterHP1_1.Ep.b,volume_HP1.Cs1.a,splitter_condenser.Cs2.a,volumeA.Cs2.a,volumeA1.Ce2.b,AirPreheater.Cs2.a,AirPreheater.Ce2.b,splitter_Turbine_HP.Cs1.a,ReheaterHP1.Ep.b,Drum_2.Cs4.a,Drum_2.Cs3.a,Drum_2.Cs2.a,Drum_2.Ce3.b,Drum_1.Cs4.a,Drum_1.Cs3.a,Drum_1.Cs2.a,Drum_1.Ce4.b,Drum_1.Ce2.b,ReheaterIP.Ep.b,ReheaterLP3.Ep.b,splitter_TurbineLP3.Ce2.b,splitter_TurbineLP2.Ce2.b,splitter_TurbineLP1.Ce2.b,splitter_TurbineIP2.Ce2.b,splitter_TurbineIP1.Ce2.b) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1102): * Single equations (assignments): 988 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 98 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 3 * Torn equation systems: 11 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 1 system {(2,100.0%)} * Non-linear Jacobian (size): 2 systems {1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(4,1,62.5%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 9 systems {(1,4), (1,3), (1,3), (1,3), (1,3), (276,1631), (1,1), (9,3), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.02561/10.18, allocations: 5.569 MB / 3.665 GB, free: 168.6 MB / 0.9513 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.01142/10.19, allocations: 2.279 MB / 3.667 GB, free: 167.7 MB / 0.9513 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.5018/10.7, allocations: 102.1 MB / 3.767 GB, free: 444.9 MB / 0.9513 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.2089/10.91, allocations: 85.33 MB / 3.85 GB, free: 389 MB / 0.9513 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0001525/10.91, allocations: 12 kB / 3.85 GB, free: 389 MB / 0.9513 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.0008474/10.91, allocations: 211.2 kB / 3.85 GB, free: 388.8 MB / 0.9513 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.3779/11.28, allocations: 162.5 MB / 4.009 GB, free: 229.9 MB / 0.9513 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0006204/11.28, allocations: 59.91 kB / 4.009 GB, free: 229.8 MB / 0.9513 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.04215/11.33, allocations: 8.954 MB / 4.018 GB, free: 221.3 MB / 0.9513 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.111/11.44, allocations: 56.65 MB / 4.073 GB, free: 164.9 MB / 0.9513 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.009529/11.45, allocations: 1.175 MB / 4.074 GB, free: 163.7 MB / 0.9513 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.4598/11.91, allocations: 171.7 MB / 4.242 GB, free: 337.9 MB / 0.9513 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 3.506e-06/11.91, allocations: 7.906 kB / 4.242 GB, free: 337.9 MB / 0.9513 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.3003/12.21, allocations: 127.3 MB / 4.366 GB, free: 250.8 MB / 0.9513 GB Notification: Performance of postOpt removeConstants (simulation): time 0.02088/12.23, allocations: 7.369 MB / 4.373 GB, free: 243.7 MB / 0.9513 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0106/12.24, allocations: 0.8091 MB / 4.374 GB, free: 242.9 MB / 0.9513 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.03381/12.27, allocations: 2.878 MB / 4.377 GB, free: 240.1 MB / 0.9513 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.01187/12.28, allocations: 2.771 MB / 4.38 GB, free: 237.3 MB / 0.9513 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.008637/12.29, allocations: 1.337 MB / 4.381 GB, free: 236 MB / 0.9513 GB Notification: Performance of sorting global known variables: time 0.005482/12.3, allocations: 4.208 MB / 4.385 GB, free: 231.8 MB / 0.9513 GB Notification: Performance of sort global known variables: time 1.11e-07/12.3, allocations: 0 / 4.385 GB, free: 231.8 MB / 0.9513 GB Notification: Performance of remove unused functions: time 0.04147/12.34, allocations: 11.28 MB / 4.396 GB, free: 220.8 MB / 0.9513 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 8 * Number of states: 152 (splitter_Turbine_HP1.P,splitter_Turbine_HP1.h,splitter_TurbineIP1.h,splitter_TurbineIP2.P,splitter_TurbineIP2.h,splitter_TurbineIP3.h,splitter_TurbineLP1.h,splitter_TurbineLP2.h,splitter_TurbineLP3.h,Condenser.P,Condenser.hl,Condenser.hv,Condenser.Vv,Drum_1.h,Drum_2.h,splitter_Turbine_HP.P,splitter_Turbine_HP.h,Wall_screen.P[2],Wall_screen.P[3],Wall_screen.P[4],Wall_screen.P[5],Wall_screen.P[6],Wall_screen.P[7],Wall_screen.P[8],Wall_screen.Q[1],Wall_screen.Q[2],Wall_screen.Q[3],Wall_screen.Q[4],Wall_screen.Q[5],Wall_screen.Q[6],Wall_screen.Q[7],Wall_screen.h[2],Wall_screen.h[3],Wall_screen.h[4],Wall_screen.h[5],Wall_screen.h[6],Wall_screen.h[7],Wall_screen.h[8],heatExchangerWall.Tp[1],heatExchangerWall.Tp[2],heatExchangerWall.Tp[3],heatExchangerWall.Tp[4],heatExchangerWall.Tp[5],heatExchangerWall.Tp[6],heatExchangerWall.Tp[7],Boiler_walls.ExchangerWall.Tp[1],Boiler_walls.ExchangerWall.Tp[2],Boiler_walls.ExchangerWall.Tp[3],Boiler_walls.TwoPhaseFlowPipe.P[2],Boiler_walls.TwoPhaseFlowPipe.P[3],Boiler_walls.TwoPhaseFlowPipe.P[4],Boiler_walls.TwoPhaseFlowPipe.Q[1],Boiler_walls.TwoPhaseFlowPipe.Q[2],Boiler_walls.TwoPhaseFlowPipe.Q[3],Boiler_walls.TwoPhaseFlowPipe.h[2],Boiler_walls.TwoPhaseFlowPipe.h[3],Boiler_walls.TwoPhaseFlowPipe.h[4],RMT_RHT.ExchangerWall.Tp[1],RMT_RHT.ExchangerWall.Tp[2],RMT_RHT.ExchangerWall.Tp[3],RMT_RHT.TwoPhaseFlowPipe.P[2],RMT_RHT.TwoPhaseFlowPipe.P[3],RMT_RHT.TwoPhaseFlowPipe.P[4],RMT_RHT.TwoPhaseFlowPipe.Q[2],RMT_RHT.TwoPhaseFlowPipe.Q[3],RMT_RHT.TwoPhaseFlowPipe.Q[4],RMT_RHT.TwoPhaseFlowPipe.h[2],RMT_RHT.TwoPhaseFlowPipe.h[3],RMT_RHT.TwoPhaseFlowPipe.h[4],SBT.ExchangerWall.Tp[1],SBT.ExchangerWall.Tp[2],SBT.ExchangerWall.Tp[3],SBT.TwoPhaseFlowPipe.P[2],SBT.TwoPhaseFlowPipe.P[3],SBT.TwoPhaseFlowPipe.P[4],SBT.TwoPhaseFlowPipe.Q[1],SBT.TwoPhaseFlowPipe.Q[2],SBT.TwoPhaseFlowPipe.Q[3],SBT.TwoPhaseFlowPipe.Q[4],SBT.TwoPhaseFlowPipe.h[2],SBT.TwoPhaseFlowPipe.h[3],SBT.TwoPhaseFlowPipe.h[4],RBT.ExchangerWall.Tp[1],RBT.ExchangerWall.Tp[2],RBT.ExchangerWall.Tp[3],RBT.TwoPhaseFlowPipe.P[2],RBT.TwoPhaseFlowPipe.P[3],RBT.TwoPhaseFlowPipe.P[4],RBT.TwoPhaseFlowPipe.Q[1],RBT.TwoPhaseFlowPipe.Q[2],RBT.TwoPhaseFlowPipe.Q[3],RBT.TwoPhaseFlowPipe.Q[4],RBT.TwoPhaseFlowPipe.h[2],RBT.TwoPhaseFlowPipe.h[3],RBT.TwoPhaseFlowPipe.h[4],Economiseur.ExchangerWall.Tp[1],Economiseur.ExchangerWall.Tp[2],Economiseur.ExchangerWall.Tp[3],Economiseur.TwoPhaseFlowPipe.P[2],Economiseur.TwoPhaseFlowPipe.P[3],Economiseur.TwoPhaseFlowPipe.P[4],Economiseur.TwoPhaseFlowPipe.Q[1],Economiseur.TwoPhaseFlowPipe.Q[2],Economiseur.TwoPhaseFlowPipe.Q[3],Economiseur.TwoPhaseFlowPipe.Q[4],Economiseur.TwoPhaseFlowPipe.h[2],Economiseur.TwoPhaseFlowPipe.h[3],Economiseur.TwoPhaseFlowPipe.h[4],SMT_SHT.ExchangerWall.Tp[1],SMT_SHT.ExchangerWall.Tp[2],SMT_SHT.ExchangerWall.Tp[3],SMT_SHT.TwoPhaseFlowPipe.P[2],SMT_SHT.TwoPhaseFlowPipe.P[3],SMT_SHT.TwoPhaseFlowPipe.P[4],SMT_SHT.TwoPhaseFlowPipe.Q[1],SMT_SHT.TwoPhaseFlowPipe.Q[2],SMT_SHT.TwoPhaseFlowPipe.Q[3],SMT_SHT.TwoPhaseFlowPipe.Q[4],SMT_SHT.TwoPhaseFlowPipe.h[2],SMT_SHT.TwoPhaseFlowPipe.h[3],SMT_SHT.TwoPhaseFlowPipe.h[4],AirPreheater.Xh2o,volumeA1.h,volumeA.P,volumeA.h,TemperatureControl.pIsat.Integrateur1.x,TemperatureControl.pT1_1.x,regulation_Level_Condenser.pIsat.Integrateur1.x,regulation_Level_Condenser.pIsat1.Integrateur1.x,regulation_Level_Condenser.pT1_1.x,regulation_Level_Condenser.pT1_2.x,regulation_Level_Condenser.pT1_3.x,splitter_condenser.h,Pump_VelocityControl.pIsat.Integrateur1.x,Pump_VelocityControl.pT1_1.x,pT1_1.x,volume_HP1.P,volume_HP1.h,volume_HP2.P,volume_HP2.h,volume_HP3.h,volume_HP1Vap.P,volume_HP1Vap.h,volume_HP1Vap1.P,volume_HP1Vap1.h,volume_HP21.P,volume_HP21.h,volume_HP22.P,volume_HP22.h,pT1_3.x,pT1_4.x,pT1_5.x) * Number of discrete variables: 13 ($whenCondition3,$whenCondition2,$whenCondition1,TemperatureControl.pIsat.Integrateur1.x0,regulation_Level_Condenser.pIsat.Integrateur1.x0,regulation_Level_Condenser.pIsat1.Integrateur1.x0,regulation_Level_Condenser.edge.uL.signal,regulation_Level_Condenser.edge.yL.signal,regulation_Level_Condenser.echelon.yL.signal,CheckValve.ouvert,CheckValve.touvert,CheckValve.tferme,Pump_VelocityControl.pIsat.Integrateur1.x0) * Number of discrete states: 5 (CheckValve.touvert,CheckValve.tferme,regulation_Level_Condenser.echelon.yL.signal,regulation_Level_Condenser.edge.yL.signal,regulation_Level_Condenser.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (3410): * Single equations (assignments): 3106 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 186 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 10 * Torn equation systems: 101 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 10 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 0 systems * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 42 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 59 systems {(1,2), (1,2), (1,2), (1,2), (1,4), (1,3), (1,2), (1,2), (1,2), (1,2), (1,2), (1,2), (1,5), (1,2), (1,2), (1,2), (1,2), (1,3), (1,1), (1,3), (80,211), (1,6), (3,7), (1,2), (1,2), (1,3), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,3), (1,6), (1,6), (1,6), (2,37), (1,6), (1,6), (1,6), (1,6), (1,6), (1,5), (1,3), (52,195), (19,42), (1,3), (1,26), (1,2), (1,2), (1,1), (1,5), (1,5), (1,3), (19,42)} Notification: Performance of Backend phase and start with SimCode phase: time 0.01954/12.36, allocations: 4.403 MB / 4.4 GB, free: 217.3 MB / 0.9513 GB Notification: Performance of simCode: created initialization part: time 0.1902/12.55, allocations: 112.4 MB / 4.51 GB, free: 100.7 MB / 0.9513 GB Notification: Performance of simCode: created event and clocks part: time 1.135e-05/12.55, allocations: 8 kB / 4.51 GB, free: 100.7 MB / 0.9513 GB Notification: Performance of simCode: created simulation system equations: time 0.1106/12.66, allocations: 52.55 MB / 4.561 GB, free: 47.2 MB / 0.9513 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.07872/12.74, allocations: 13.94 MB / 4.575 GB, free: 33.99 MB / 0.9513 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.5201/13.26, allocations: 102.8 MB / 4.675 GB, free: 383.7 MB / 0.9513 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.02469/13.28, allocations: 17.15 MB / 4.692 GB, free: 381.8 MB / 0.9513 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01354/13.3, allocations: 1.923 MB / 4.694 GB, free: 381.7 MB / 0.9513 GB Notification: Performance of SimCode: time 1.774e-06/13.3, allocations: 0 / 4.694 GB, free: 381.7 MB / 0.9513 GB Notification: Performance of Templates: time 16.51/29.81, allocations: 9.102 GB / 13.8 GB, free: 357.6 MB / 0.9514 GB " [Timeout remaining time 630] make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant.makefile [Timeout 660] make -j1 -f ThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelica/OMCompiler/build/include/omc/sundials" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.o OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.cpp In file included from OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgLoopMain.cpp:45: ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:85:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp1251.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:86:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp1251.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:87:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp1251.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:88:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp1251.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:89:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp1251.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:90:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_pt_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_pt_ = get<0>(tmp1251.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:91:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cv_' _Boiler_walls_P_TwoPhaseFlowPipe_P_lsat2_P_cv_ = get<0>(tmp1251.data).cv_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:92:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_P_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_P_ = get<1>(tmp1251.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:93:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_T_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_T_ = get<1>(tmp1251.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:94:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_rho_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_rho_ = get<1>(tmp1251.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:95:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_h_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_h_ = get<1>(tmp1251.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:96:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cp_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cp_ = get<1>(tmp1251.data).cp_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:97:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_pt_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_pt_ = get<1>(tmp1251.data).pt_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop5401.cpp:98:3: error: use of undeclared identifier '_Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cv_' _Boiler_walls_P_TwoPhaseFlowPipe_P_vsat2_P_cv_ = get<1>(tmp1251.data).cv_; ^ In file included from OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.cpp:25: In file included from ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgLoopMain.cpp:120: ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:95:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_P_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_P_ = get<0>(tmp1497.data).P_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:96:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_T_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_T_ = get<0>(tmp1497.data).T_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:97:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_rho_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_rho_ = get<0>(tmp1497.data).rho_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:98:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_h_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_h_ = get<0>(tmp1497.data).h_; ^ ./OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantAlgloop6992.cpp:99:3: error: use of undeclared identifier '_RBT_P_TwoPhaseFlowPipe_P_lsat2_P_cp_' _RBT_P_TwoPhaseFlowPipe_P_lsat2_P_cp_ = get<0>(tmp1497.data).cp_; ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. make: *** [: OMCppThermoSysPro_ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlantCalcHelperMain.o] Error 1 [Calling os._exit(0), Time elapsed: 34.29696832294576] Failed to read output from testmodel.py, exit status != 0: 29.94212472299114 29.950031965 26.553059444 Calling exit ...