Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.7788/0.7788, allocations: 152.6 MB / 169.6 MB, free: 15.13 MB / 142.1 MB " [Timeout remaining time 179] Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin") translateModel(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.SimpleExamples.TestFan_Qin") [Timeout 660] "Notification: Performance of FrontEnd - loaded program: time 0.000472/0.000472, allocations: 18.36 kB / 245.6 MB, free: 15.56 MB / 206.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.052/0.05248, allocations: 33.06 MB / 278.7 MB, free: 0.6094 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.SimpleExamples.TestFan_Qin): time 1.53/1.583, allocations: 305.7 MB / 0.5707 GB, free: 14.07 MB / 462.1 MB Notification: Performance of NFInst.instExpressions: time 0.4041/1.987, allocations: 152.9 MB / 0.72 GB, free: 0.7305 MB / 0.5762 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0004178/1.987, allocations: 12.97 kB / 0.72 GB, free: 0.7305 MB / 0.5762 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/Sink.mo:15:3-17:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:52:3-54:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:55:3-56:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeATh.mo:59:3-60:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeCTh.mo:49:3-51:16:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeCTh.mo:52:3-53:83:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeCTh.mo:56:3-57:83:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeCTh.mo:58:3-60:16:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:18:3-20:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/SingularPressureLoss.mo:21:3-23:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:57:3-59:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/StaticFan.mo:60:3-62:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:27:3-28:49:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/PressureLosses/CheckValve.mo:29:3-30:47:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:24:3-26:24:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:27:3-28:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Junctions/Mixer2.mo:30:3-32:17:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:48:3-50:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:51:3-52:83:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:53:3-55:16:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Volumes/VolumeDTh.mo:56:3-57:83:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:10:3-12:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Sensors/TemperatureSensor.mo:13:3-15:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.0005183/1.988, allocations: 220.7 kB / 0.7202 GB, free: 0.7266 MB / 0.5762 GB Notification: Performance of NFTyping.typeBindings: time 0.0007149/1.988, allocations: 494.8 kB / 0.7207 GB, free: 0.7188 MB / 0.5762 GB Notification: Performance of NFTyping.typeClassSections: time 0.002878/1.991, allocations: 1.506 MB / 0.7221 GB, free: 0.6875 MB / 0.5762 GB Notification: Performance of NFFlatten.flatten: time 0.001841/1.993, allocations: 2.352 MB / 0.7244 GB, free: 0.6797 MB / 0.5762 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001033/1.994, allocations: 1.024 MB / 0.7254 GB, free: 16.55 MB / 0.5919 GB Notification: Performance of NFEvalConstants.evaluate: time 0.0007046/1.995, allocations: 0.8773 MB / 0.7263 GB, free: 16.55 MB / 0.5919 GB Notification: Performance of NFSimplifyModel.simplify: time 0.0009126/1.996, allocations: 1.059 MB / 0.7273 GB, free: 16.55 MB / 0.5919 GB Notification: Performance of NFPackage.collectConstants: time 0.0002438/1.996, allocations: 244.4 kB / 0.7276 GB, free: 16.55 MB / 0.5919 GB Notification: Performance of NFFlatten.collectFunctions: time 0.002103/1.998, allocations: 1.225 MB / 0.7288 GB, free: 16.54 MB / 0.5919 GB Notification: Performance of NFScalarize.scalarize: time 0.0003033/1.998, allocations: 0.5004 MB / 0.7292 GB, free: 16.54 MB / 0.5919 GB Notification: Performance of NFVerifyModel.verify: time 0.0007754/1.999, allocations: 1.03 MB / 0.7302 GB, free: 16.53 MB / 0.5919 GB Notification: Performance of NFConvertDAE.convert: time 0.002441/2.002, allocations: 2.891 MB / 0.7331 GB, free: 16.14 MB / 0.5919 GB Notification: Performance of FrontEnd - DAE generated: time 3.025e-06/2.002, allocations: 0 / 0.7331 GB, free: 16.14 MB / 0.5919 GB Notification: Performance of FrontEnd: time 1.052e-06/2.002, allocations: 0 / 0.7331 GB, free: 16.14 MB / 0.5919 GB Notification: Performance of Transformations before backend: time 2.466e-05/2.002, allocations: 0 / 0.7331 GB, free: 16.14 MB / 0.5919 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 508 * Number of variables: 508 Notification: Performance of Generate backend data structure: time 0.003744/2.005, allocations: 2.271 MB / 0.7353 GB, free: 15.12 MB / 0.5919 GB Notification: Performance of prepare preOptimizeDAE: time 3.026e-05/2.005, allocations: 9.625 kB / 0.7353 GB, free: 15.12 MB / 0.5919 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.0003464/2.006, allocations: 225.9 kB / 0.7355 GB, free: 15.02 MB / 0.5919 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.0008139/2.006, allocations: 0.7311 MB / 0.7362 GB, free: 14.69 MB / 0.5919 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0001426/2.007, allocations: 213.5 kB / 0.7364 GB, free: 14.62 MB / 0.5919 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0003688/2.007, allocations: 224.5 kB / 0.7366 GB, free: 14.62 MB / 0.5919 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.002957/2.01, allocations: 2.346 MB / 0.7389 GB, free: 14.11 MB / 0.5919 GB Notification: Performance of preOpt findStateOrder (simulation): time 3.318e-05/2.01, allocations: 5.969 kB / 0.7389 GB, free: 14.11 MB / 0.5919 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001375/2.01, allocations: 87.62 kB / 0.739 GB, free: 14.11 MB / 0.5919 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 2.834e-05/2.01, allocations: 52.38 kB / 0.7391 GB, free: 14.11 MB / 0.5919 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.002771/2.013, allocations: 2.048 MB / 0.7411 GB, free: 14.09 MB / 0.5919 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.01143/2.024, allocations: 14.56 MB / 0.7553 GB, free: 2.793 MB / 0.5919 GB Notification: Performance of preOpt comSubExp (simulation): time 0.001534/2.026, allocations: 1.024 MB / 0.7563 GB, free: 2.723 MB / 0.5919 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.000993/2.027, allocations: 0.7465 MB / 0.757 GB, free: 2.695 MB / 0.5919 GB Notification: Performance of preOpt evalFunc (simulation): time 0.000635/2.027, allocations: 0.4897 MB / 0.7575 GB, free: 2.312 MB / 0.5919 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.001133/2.029, allocations: 0.844 MB / 0.7583 GB, free: 2.223 MB / 0.5919 GB Notification: Performance of pre-optimization done (n=128): time 2.354e-06/2.029, allocations: 0 / 0.7583 GB, free: 2.223 MB / 0.5919 GB Warning: Some equations could not be differentiated for following variables having attribute stateSelect=StateSelect.prefer. They will be treated as if they had stateSelect=StateSelect.default ======================================== 1: volume2S.T Please use -d=bltdump for more information. Notification: Performance of matching and sorting (n=213): time 0.1563/2.185, allocations: 32.12 MB / 0.7897 GB, free: 2.695 MB / 0.6075 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 3.568877901881933] Failed to read output from testmodel.py, exit status != 0: 2.320791852893308 2.334053718 0.329693087 Calling exit ...