Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.Simulators.CCPP_Sim3.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.002014/0.002014, allocations: 123.4 kB / 18.46 MB, free: 4.598 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001954/0.001954, allocations: 192.3 kB / 21.4 MB, free: 1.668 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.618/1.618, allocations: 207.6 MB / 231.8 MB, free: 4.086 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo): time 0.4628/0.4628, allocations: 49.51 MB / 333.1 MB, free: 0.7305 MB / 254.1 MB " [Timeout remaining time 179] Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(ThermoPower.PowerPlants.Simulators.CCPP_Sim3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=3000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.Simulators.CCPP_Sim3") translateModel(ThermoPower.PowerPlants.Simulators.CCPP_Sim3,tolerance=1e-06,outputFormat="empty",numberOfIntervals=3000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.Simulators.CCPP_Sim3") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002078/0.002078, allocations: 69.92 kB / 471.9 MB, free: 40.64 MB / 382.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1142/0.1163, allocations: 62.33 MB / 0.5217 GB, free: 1.773 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Sources.mo:388:5-389:46:writable] Warning: Parameter valveHP_com.duration has no value, and is fixed during initialization (fixed=true), using available start value (start=2) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Sources.mo:388:5-389:46:writable] Warning: Parameter valveIP_com.duration has no value, and is fixed during initialization (fixed=true), using available start value (start=2) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Sources.mo:388:5-389:46:writable] Warning: Parameter valveLP_com.duration has no value, and is fixed during initialization (fixed=true), using available start value (start=2) as default value. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/PowerPlants.mo:17812:11-17812:20:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo:145:5-145:107:writable] Error: Trying to override final element J with modifier '= J_shaft'. Notification: Performance of FrontEnd: time 2.581/2.697, allocations: 0.7992 GB / 1.321 GB, free: 15.64 MB / 0.8262 GB " [Timeout remaining time 657] [Calling sys.exit(0), Time elapsed: 5.757503239903599] Failed to read output from testmodel.py, exit status != 0: 2.7036188279744238 2.715381301 -1.0 Calling exit ...