Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Cycles.simpleRecupCycleHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001547/0.001547, allocations: 115.2 kB / 17.13 MB, free: 5.914 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001316/0.001316, allocations: 193.2 kB / 20.08 MB, free: 2.98 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.393/1.393, allocations: 207.6 MB / 230.5 MB, free: 4.012 MB / 174.1 MB " [Timeout remaining time 179] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo): time 0.1312/0.1312, allocations: 25.05 MB / 307.4 MB, free: 7.199 MB / 254.1 MB " [Timeout remaining time 180] Using package SolarTherm with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -outputFormat=mat since it seems broken on HelloWorld Running command: translateModel(SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Cycles.simpleRecupCycleHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Cycles.simpleRecupCycleHeater") translateModel(SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Cycles.simpleRecupCycleHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=500,variableFilter="",fileNamePrefix="SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OnDesign.Cycles.simpleRecupCycleHeater") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002205/0.002205, allocations: 71.89 kB / 435.2 MB, free: 6.562 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2226/0.2248, allocations: 55 MB / 490.2 MB, free: 13.82 MB / 350.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/Media/CO2/CO2_ph.mo:127:7-127:68:writable] Error: Invalid prefix outer on formal parameter tableIDh_p_T. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] Error: Class Medium.MassFlowRate not found in scope FluidPort. Notification: Performance of FrontEnd: time 0.005427/0.2302, allocations: 3.26 MB / 493.5 MB, free: 10.54 MB / 350.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.452658792026341] Failed to read output from testmodel.py, exit status != 0: 0.23697378486394882 0.24995039599999996 -1.0 Calling exit ...