Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001523/0.001523, allocations: 112.9 kB / 17.82 MB, free: 5.324 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001821/0.001821, allocations: 199.3 kB / 20.78 MB, free: 2.379 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.483/1.483, allocations: 207.6 MB / 231.2 MB, free: 4.07 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo): time 0.6121/0.6121, allocations: 114.4 MB / 397.5 MB, free: 3.387 MB / 318.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.8.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Dynawo.Examples.IEEE14.TestCases.IEEE14CLA,tolerance=1e-06,outputFormat="mat",numberOfIntervals=20,variableFilter="time|Gen1.PGenPu|Gen1.QGenPu|Gen1.UPu|Gen2.PGenPu|Gen2.QGenPu|Gen2.UPu|Gen3.PGenPu|Gen3.QGenPu|Gen3.UPu|Gen6.PGenPu|Gen6.QGenPu|Gen6.UPu|Gen8.PGenPu|Gen8.QGenPu|Gen8.UPu|Load2.PPu|Load2.QPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA") translateModel(Dynawo.Examples.IEEE14.TestCases.IEEE14CLA,tolerance=1e-06,outputFormat="mat",numberOfIntervals=20,variableFilter="time|Gen1.PGenPu|Gen1.QGenPu|Gen1.UPu|Gen2.PGenPu|Gen2.QGenPu|Gen2.UPu|Gen3.PGenPu|Gen3.QGenPu|Gen3.UPu|Gen6.PGenPu|Gen6.QGenPu|Gen6.UPu|Gen8.PGenPu|Gen8.QGenPu|Gen8.UPu|Load2.PPu|Load2.QPu",fileNamePrefix="Dynawo_dev_Dynawo.Examples.IEEE14.TestCases.IEEE14CLA") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002255/0.002255, allocations: 71.91 kB / 0.5591 GB, free: 14.19 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4139/0.4161, allocations: 78.59 MB / 0.6358 GB, free: 12.12 MB / 494.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.IEEE14.TestCases.IEEE14CLA): time 0.01475/0.4309, allocations: 18.35 MB / 0.6537 GB, free: 15.68 MB / 0.4981 GB Notification: Performance of NFInst.instExpressions: time 0.01736/0.4483, allocations: 7.866 MB / 0.6614 GB, free: 10.04 MB / 0.4981 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.004953/0.4532, allocations: 81.09 kB / 0.6615 GB, free: 10.02 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:30:3-30:140:writable] Warning: Connector QGenPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:32:3-32:113:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:30:3-30:140:writable] Warning: Connector QGenPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:32:3-32:113:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:30:3-30:140:writable] Warning: Connector QGenPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:32:3-32:113:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:30:3-30:140:writable] Warning: Connector QGenPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:32:3-32:113:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:30:3-30:140:writable] Warning: Connector QGenPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:32:3-32:113:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/BaseClasses/BaseQStator.mo:19:3-19:123:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/BaseClasses/BaseLoad.mo:32:3-32:125:writable] Warning: Connector UPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:28:3-28:137:writable] Warning: Connector AutomatonExists is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:29:3-29:87:writable] Warning: Connector IMonitored is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:32:3-32:177:writable] Warning: Connector order is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:28:3-28:137:writable] Warning: Connector AutomatonExists is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:29:3-29:87:writable] Warning: Connector IMonitored is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:32:3-32:177:writable] Warning: Connector order is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:28:3-28:137:writable] Warning: Connector AutomatonExists is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:29:3-29:87:writable] Warning: Connector IMonitored is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:32:3-32:177:writable] Warning: Connector order is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.004688/0.4579, allocations: 0.9949 MB / 0.6625 GB, free: 9.492 MB / 0.4981 GB Notification: Performance of NFTyping.typeBindings: time 0.006867/0.4648, allocations: 1.174 MB / 0.6636 GB, free: 8.645 MB / 0.4981 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:57:5-57:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:59:5-59:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:64:5-64:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:66:5-66:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:71:5-71:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:73:5-73:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:136:3-136:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:137:3-137:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:139:3-139:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:140:3-140:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:142:3-142:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:143:3-143:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:145:3-145:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:146:3-146:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:148:3-148:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:149:3-149:38:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:151:3-151:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:153:3-153:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:155:3-155:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:157:3-157:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:159:3-159:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:161:3-161:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:163:3-163:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:165:3-165:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:167:3-167:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:169:3-169:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:171:3-171:40:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:173:3-173:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:175:3-175:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:177:3-177:44:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:181:3-181:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:183:3-183:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:186:3-186:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:188:3-188:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:190:3-190:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:192:3-192:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:194:3-194:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:196:3-196:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:198:3-198:42:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:200:3-200:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:202:3-202:43:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:204:3-204:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:206:3-206:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:208:3-208:38:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Examples/IEEE14/TestCases/IEEE14CLA.mo:210:3-210:39:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen1.UPu == Gen1.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen1.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen1.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen2.UPu == Gen2.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen2.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen2.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen3.UPu == Gen3.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen3.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen3.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen6.UPu == Gen6.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen6.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen6.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/SignalN/GeneratorPV.mo:21:3-42:11:writable] Warning: In relation Gen8.UPu == Gen8.URefPu, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen8.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Machines/BaseClasses/BaseGeneratorSimplified.mo:40:5-44:11:writable] Warning: In relation Gen8.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load2.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load2.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load3.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load3.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load4.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load4.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load5.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load5.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load6.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load6.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load9.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load9.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load10.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load10.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load11.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load11.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load12.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load12.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load13.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load13.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load14.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Loads/LoadAlphaBetaRestorative.mo:31:5-39:11:writable] Warning: In relation Load14.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus1.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus1.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus2.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus2.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus3.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus3.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus4.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus4.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus5.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus5.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus6.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus6.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus7.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus7.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus8.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus8.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus9.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus9.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus10.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus10.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus11.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus11.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus12.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus12.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus13.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus13.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus14.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Buses/Bus.mo:29:3-33:9:writable] Warning: In relation Bus14.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation Tfo1.terminal1.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation Tfo1.terminal1.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation Tfo1.terminal2.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation Tfo1.terminal2.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation Tfo2.terminal1.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation Tfo2.terminal1.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation Tfo2.terminal2.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation Tfo2.terminal2.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation Tfo3.terminal1.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:61:5-65:11:writable] Warning: In relation Tfo3.terminal1.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation Tfo3.terminal2.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Transformers/TransformersFixedTap/TransformerFixedRatio.mo:66:5-70:11:writable] Warning: In relation Tfo3.terminal2.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Shunts/ShuntB.mo:35:3-39:9:writable] Warning: In relation Bank9.terminal.V.re == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Shunts/ShuntB.mo:35:3-39:9:writable] Warning: In relation Bank9.terminal.V.im == 0.0, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:39:3-47:11:writable] Warning: In relation pre(CLAB1B2.tThresholdReached) <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:49:3-51:11:writable] Warning: In relation CLAB1B2.tThresholdReached <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:49:3-51:11:writable] Warning: In relation CLAB1B2.tOrder == Modelica.Constants.inf, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:39:3-47:11:writable] Warning: In relation pre(CLAB2B5.tThresholdReached) <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:49:3-51:11:writable] Warning: In relation CLAB2B5.tThresholdReached <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:49:3-51:11:writable] Warning: In relation CLAB2B5.tOrder == Modelica.Constants.inf, == on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:39:3-47:11:writable] Warning: In relation pre(CLAB1B5.tThresholdReached) <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:49:3-51:11:writable] Warning: In relation CLAB1B5.tThresholdReached <> Modelica.Constants.inf, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo master/Electrical/Controls/Current/CurrentLimitAutomaton.mo:49:3-51:11:writable] Warning: In relation CLAB1B5.tOrder == Modelica.Constants.inf, == on Real numbers is only allowed inside functions. Notification: Performance of NFTyping.typeClassSections: time 0.01133/0.4761, allocations: 3.325 MB / 0.6669 GB, free: 6.879 MB / 0.4981 GB Notification: Performance of NFFlatten.flatten: time 0.01252/0.4886, allocations: 5.989 MB / 0.6727 GB, free: 3.734 MB / 0.4981 GB Notification: Performance of NFFlatten.resolveConnections: time 0.002184/0.4908, allocations: 0.8056 MB / 0.6735 GB, free: 3.191 MB / 0.4981 GB Notification: Performance of NFEvalConstants.evaluate: time 0.005192/0.496, allocations: 2.416 MB / 0.6759 GB, free: 1.688 MB / 0.4981 GB Notification: Performance of NFSimplifyModel.simplify: time 0.005289/0.5013, allocations: 2.77 MB / 0.6786 GB, free: 15.68 MB / 0.5137 GB Notification: Performance of NFPackage.collectConstants: time 0.002654/0.5039, allocations: 0.5208 MB / 0.6791 GB, free: 15.68 MB / 0.5137 GB Notification: Performance of NFFlatten.collectFunctions: time 0.003354/0.5073, allocations: 0.7436 MB / 0.6798 GB, free: 15.6 MB / 0.5137 GB Notification: Performance of NFScalarize.scalarize: time 0.002138/0.5094, allocations: 1.339 MB / 0.6811 GB, free: 14.48 MB / 0.5137 GB Notification: Performance of NFVerifyModel.verify: time 0.004293/0.5137, allocations: 2.447 MB / 0.6835 GB, free: 12.56 MB / 0.5137 GB Notification: Performance of NFConvertDAE.convert: time 0.01005/0.5238, allocations: 6.053 MB / 0.6894 GB, free: 7.93 MB / 0.5137 GB Notification: Performance of FrontEnd - DAE generated: time 6.833e-06/0.5238, allocations: 1.062 kB / 0.6894 GB, free: 7.93 MB / 0.5137 GB Notification: Performance of FrontEnd: time 2.124e-06/0.5238, allocations: 0 / 0.6894 GB, free: 7.93 MB / 0.5137 GB Notification: Performance of Transformations before backend: time 0.0002332/0.524, allocations: 0 / 0.6894 GB, free: 7.93 MB / 0.5137 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 802 * Number of variables: 802 Notification: Performance of Generate backend data structure: time 0.03775/0.5618, allocations: 9.748 MB / 0.6989 GB, free: 1.832 MB / 0.5137 GB Notification: Performance of prepare preOptimizeDAE: time 6.539e-05/0.5618, allocations: 17.53 kB / 0.6989 GB, free: 1.824 MB / 0.5137 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02268/0.5845, allocations: 3.144 MB / 0.702 GB, free: 15.45 MB / 0.5294 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.008897/0.5934, allocations: 3.087 MB / 0.705 GB, free: 12.3 MB / 0.5294 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.002812/0.5962, allocations: 3.287 MB / 0.7082 GB, free: 8.344 MB / 0.5294 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001381/0.5976, allocations: 388.3 kB / 0.7086 GB, free: 7.965 MB / 0.5294 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.0116/0.6092, allocations: 5.307 MB / 0.7138 GB, free: 2.605 MB / 0.5294 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.744e-05/0.6092, allocations: 0 / 0.7138 GB, free: 2.605 MB / 0.5294 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0006366/0.6099, allocations: 191.9 kB / 0.714 GB, free: 2.418 MB / 0.5294 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 6.279e-05/0.6099, allocations: 80 kB / 0.714 GB, free: 2.34 MB / 0.5294 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.008995/0.6189, allocations: 4.351 MB / 0.7183 GB, free: 13.98 MB / 0.545 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.04353/0.6625, allocations: 20.62 MB / 0.7384 GB, free: 8.727 MB / 0.5606 GB Notification: Performance of preOpt comSubExp (simulation): time 0.008934/0.6714, allocations: 4.07 MB / 0.7424 GB, free: 4.633 MB / 0.5606 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.006731/0.6781, allocations: 2.846 MB / 0.7452 GB, free: 1.777 MB / 0.5606 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0007247/0.6789, allocations: 140.8 kB / 0.7453 GB, free: 1.621 MB / 0.5606 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.01276/0.6916, allocations: 5.417 MB / 0.7506 GB, free: 12.16 MB / 0.5762 GB Notification: Performance of pre-optimization done (n=669): time 1.402e-05/0.6916, allocations: 4 kB / 0.7506 GB, free: 12.15 MB / 0.5762 GB Notification: Performance of matching and sorting (n=669): time 0.03621/0.7278, allocations: 12 MB / 0.7623 GB, free: 80 kB / 0.5762 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002828/0.7281, allocations: 196.6 kB / 0.7625 GB, free: 15.87 MB / 0.5919 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.004368/0.7325, allocations: 2.381 MB / 0.7648 GB, free: 13.48 MB / 0.5919 GB Notification: Performance of collectPreVariables (initialization): time 0.001586/0.7341, allocations: 245.6 kB / 0.7651 GB, free: 13.24 MB / 0.5919 GB Notification: Performance of collectInitialEqns (initialization): time 0.001552/0.7356, allocations: 1.383 MB / 0.7664 GB, free: 11.84 MB / 0.5919 GB Notification: Performance of collectInitialBindings (initialization): time 0.003552/0.7392, allocations: 1.976 MB / 0.7684 GB, free: 9.852 MB / 0.5919 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.00406/0.7432, allocations: 1.05 MB / 0.7694 GB, free: 8.793 MB / 0.5919 GB Notification: Performance of setup shared object (initialization): time 0.0001368/0.7434, allocations: 301.1 kB / 0.7697 GB, free: 8.496 MB / 0.5919 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.006958/0.7503, allocations: 2.743 MB / 0.7723 GB, free: 5.75 MB / 0.5919 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.008634/0.759, allocations: 4.165 MB / 0.7764 GB, free: 1.035 MB / 0.5919 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.0387/0.7977, allocations: 14.04 MB / 0.7901 GB, free: 2.344 MB / 0.6075 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 7.738e-05/0.7977, allocations: 12 kB / 0.7901 GB, free: 2.332 MB / 0.6075 GB Notification: Performance of matching and sorting (n=919) (initialization): time 0.05332/0.8511, allocations: 12.49 MB / 0.8023 GB, free: 5.766 MB / 0.6231 GB Notification: Performance of prepare postOptimizeDAE: time 8.388e-05/0.8511, allocations: 24 kB / 0.8023 GB, free: 5.742 MB / 0.6231 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 7.724e-05/0.8512, allocations: 36 kB / 0.8024 GB, free: 5.707 MB / 0.6231 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.01595/0.8672, allocations: 8.012 MB / 0.8102 GB, free: 13.69 MB / 0.6387 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.007258/0.8744, allocations: 0.8654 MB / 0.8111 GB, free: 12.82 MB / 0.6387 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.01661/0.891, allocations: 5.887 MB / 0.8168 GB, free: 6.898 MB / 0.6387 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.007019/0.8981, allocations: 0.6263 MB / 0.8174 GB, free: 6.27 MB / 0.6387 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001457/0.8995, allocations: 259.9 kB / 0.8177 GB, free: 6.016 MB / 0.6387 GB Warning: Assuming fixed start value for the following 118 variables: Gen1.limUQUp:DISCRETE(flow=false start = Gen1.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen1.limUQDown:DISCRETE(flow=false start = Gen1.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen2.limUQUp:DISCRETE(flow=false start = Gen2.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen2.limUQDown:DISCRETE(flow=false start = Gen2.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen3.limUQUp:DISCRETE(flow=false start = Gen3.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen3.limUQDown:DISCRETE(flow=false start = Gen3.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen6.limUQUp:DISCRETE(flow=false start = Gen6.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen6.limUQDown:DISCRETE(flow=false start = Gen6.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen8.limUQUp:DISCRETE(flow=false start = Gen8.limUQUp0 fixed = true ) \"Whether the maximum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Gen8.limUQDown:DISCRETE(flow=false start = Gen8.limUQDown0 fixed = true ) \"Whether the minimum reactive power limits are reached or not (from generator voltage regulator)\" type: Boolean Load2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load2.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load3.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load4.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load5.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load6.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load6.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load9.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load10.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load10.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load11.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load12.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load13.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Load14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Load14.State0 fixed = true ) \"Load connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB10B11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB10B11.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB12B13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB12B13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB13B14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB13B14.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB1B2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB1B2.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB1B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB1B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B3.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB2B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB2B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB3B4.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB3B4.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB4B5.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB4B5.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B11.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B11.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B12.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B12.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB6B13.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB6B13.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB7B8.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB7B8.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB7B9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB7B9.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB9B10.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB9B10.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) LineB9B14.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = LineB9B14.State0 fixed = true ) \"Line connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo1.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo2.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Tfo3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Tfo3.State0 fixed = true ) \"Transformer connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Bank9.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Bank9.State0 fixed = true ) \"Shunt connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen8.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen8.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen6.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen6.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen3.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen3.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen2.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen2.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen1.state:DISCRETE(min = Dynawo.Electrical.Constants.state.Open max = Dynawo.Electrical.Constants.state.Undefined start = Gen1.State0 fixed = true ) \"Generator connection state\" type: enumeration(Open, Closed, Closed1, Closed2, Closed3, Undefined) Gen1.running.value:DISCRETE(flow=false start = Gen1.Running0 fixed = true ) type: Boolean Gen2.running.value:DISCRETE(flow=false start = Gen2.Running0 fixed = true ) type: Boolean Gen3.running.value:DISCRETE(flow=false start = Gen3.Running0 fixed = true ) type: Boolean Gen6.running.value:DISCRETE(flow=false start = Gen6.Running0 fixed = true ) type: Boolean Gen8.running.value:DISCRETE(flow=false start = Gen8.Running0 fixed = true ) type: Boolean ModelSignalN.thetaRef:VARIABLE(start = 0.0 unit = \"rad\" fixed = true ) \"Voltage angle reference\" type: Real Load2.running.value:DISCRETE(flow=false start = Load2.Running0 fixed = true ) type: Boolean Load2.UFilteredRawPu:VARIABLE(start = (Load2.u0Pu.re ^ 2.0 + Load2.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load3.running.value:DISCRETE(flow=false start = Load3.Running0 fixed = true ) type: Boolean Load3.UFilteredRawPu:VARIABLE(start = (Load3.u0Pu.re ^ 2.0 + Load3.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load4.running.value:DISCRETE(flow=false start = Load4.Running0 fixed = true ) type: Boolean Load4.UFilteredRawPu:VARIABLE(start = (Load4.u0Pu.re ^ 2.0 + Load4.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load5.running.value:DISCRETE(flow=false start = Load5.Running0 fixed = true ) type: Boolean Load5.UFilteredRawPu:VARIABLE(start = (Load5.u0Pu.re ^ 2.0 + Load5.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load6.running.value:DISCRETE(flow=false start = Load6.Running0 fixed = true ) type: Boolean Load6.UFilteredRawPu:VARIABLE(start = (Load6.u0Pu.re ^ 2.0 + Load6.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load9.running.value:DISCRETE(flow=false start = Load9.Running0 fixed = true ) type: Boolean Load9.UFilteredRawPu:VARIABLE(start = (Load9.u0Pu.re ^ 2.0 + Load9.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load10.running.value:DISCRETE(flow=false start = Load10.Running0 fixed = true ) type: Boolean Load10.UFilteredRawPu:VARIABLE(start = (Load10.u0Pu.re ^ 2.0 + Load10.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load11.running.value:DISCRETE(flow=false start = Load11.Running0 fixed = true ) type: Boolean Load11.UFilteredRawPu:VARIABLE(start = (Load11.u0Pu.re ^ 2.0 + Load11.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load12.running.value:DISCRETE(flow=false start = Load12.Running0 fixed = true ) type: Boolean Load12.UFilteredRawPu:VARIABLE(start = (Load12.u0Pu.re ^ 2.0 + Load12.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load13.running.value:DISCRETE(flow=false start = Load13.Running0 fixed = true ) type: Boolean Load13.UFilteredRawPu:VARIABLE(start = (Load13.u0Pu.re ^ 2.0 + Load13.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real Load14.running.value:DISCRETE(flow=false start = Load14.Running0 fixed = true ) type: Boolean Load14.UFilteredRawPu:VARIABLE(start = (Load14.u0Pu.re ^ 2.0 + Load14.u0Pu.im ^ 2.0) ^ 0.5 unit = \"1\" fixed = true protected = true ) \"Filtered voltage amplitude at terminal in pu (base UNom)\" type: Real LineB10B11.running.value:DISCRETE(flow=false start = LineB10B11.Running0 fixed = true ) type: Boolean LineB12B13.running.value:DISCRETE(flow=false start = LineB12B13.Running0 fixed = true ) type: Boolean LineB13B14.running.value:DISCRETE(flow=false start = LineB13B14.Running0 fixed = true ) type: Boolean LineB1B2.switchOffSignal2.value:DISCRETE(flow=false start = LineB1B2.SwitchOffSignal20 fixed = true ) type: Boolean LineB1B2.running.value:DISCRETE(flow=false start = LineB1B2.Running0 fixed = true ) type: Boolean LineB1B5.switchOffSignal2.value:DISCRETE(flow=false start = LineB1B5.SwitchOffSignal20 fixed = true ) type: Boolean LineB1B5.running.value:DISCRETE(flow=false start = LineB1B5.Running0 fixed = true ) type: Boolean LineB2B3.running.value:DISCRETE(flow=false start = LineB2B3.Running0 fixed = true ) type: Boolean LineB2B4.running.value:DISCRETE(flow=false start = LineB2B4.Running0 fixed = true ) type: Boolean LineB2B5.switchOffSignal2.value:DISCRETE(flow=false start = LineB2B5.SwitchOffSignal20 fixed = true ) type: Boolean LineB2B5.running.value:DISCRETE(flow=false start = LineB2B5.Running0 fixed = true ) type: Boolean LineB3B4.running.value:DISCRETE(flow=false start = LineB3B4.Running0 fixed = true ) type: Boolean LineB4B5.running.value:DISCRETE(flow=false start = LineB4B5.Running0 fixed = true ) type: Boolean LineB6B11.running.value:DISCRETE(flow=false start = LineB6B11.Running0 fixed = true ) type: Boolean LineB6B12.running.value:DISCRETE(flow=false start = LineB6B12.Running0 fixed = true ) type: Boolean LineB6B13.running.value:DISCRETE(flow=false start = LineB6B13.Running0 fixed = true ) type: Boolean LineB7B8.running.value:DISCRETE(flow=false start = LineB7B8.Running0 fixed = true ) type: Boolean LineB7B9.running.value:DISCRETE(flow=false start = LineB7B9.Running0 fixed = true ) type: Boolean LineB9B10.running.value:DISCRETE(flow=false start = LineB9B10.Running0 fixed = true ) type: Boolean LineB9B14.running.value:DISCRETE(flow=false start = LineB9B14.Running0 fixed = true ) type: Boolean Tfo1.running.value:DISCRETE(flow=false start = Tfo1.Running0 fixed = true ) type: Boolean Tfo2.running.value:DISCRETE(flow=false start = Tfo2.Running0 fixed = true ) type: Boolean Tfo3.running.value:DISCRETE(flow=false start = Tfo3.Running0 fixed = true ) type: Boolean Bank9.running.value:DISCRETE(flow=false start = Bank9.Running0 fixed = true ) type: Boolean CLAB1B2.tThresholdReached:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Time when IMonitored > IMax was first reached in s\" type: Real CLAB1B2.tOrder:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Last time the automaton emitted an order in s\" type: Real CLAB2B5.tThresholdReached:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Time when IMonitored > IMax was first reached in s\" type: Real CLAB2B5.tOrder:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Last time the automaton emitted an order in s\" type: Real CLAB1B5.tThresholdReached:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Time when IMonitored > IMax was first reached in s\" type: Real CLAB1B5.tOrder:DISCRETE(start = 1e60 unit = \"s\" fixed = true protected = true ) \"Last time the automaton emitted an order in s\" type: Real CLAB1B5.order.value:DISCRETE(flow=false fixed = true ) type: Integer CLAB2B5.order.value:DISCRETE(flow=false fixed = true ) type: Integer CLAB1B2.order.value:DISCRETE(flow=false fixed = true ) type: Integer Gen8.qStatus:DISCRETE(min = Gen8.QStatus.Standard max = Gen8.QStatus.GenerationMax start = Gen8.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen8.pStatus:DISCRETE(min = Gen8.PStatus.Standard max = Gen8.PStatus.LimitPMax start = Gen8.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen6.qStatus:DISCRETE(min = Gen6.QStatus.Standard max = Gen6.QStatus.GenerationMax start = Gen6.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen6.pStatus:DISCRETE(min = Gen6.PStatus.Standard max = Gen6.PStatus.LimitPMax start = Gen6.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen3.qStatus:DISCRETE(min = Gen3.QStatus.Standard max = Gen3.QStatus.GenerationMax start = Gen3.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen3.pStatus:DISCRETE(min = Gen3.PStatus.Standard max = Gen3.PStatus.LimitPMax start = Gen3.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen2.qStatus:DISCRETE(min = Gen2.QStatus.Standard max = Gen2.QStatus.GenerationMax start = Gen2.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen2.pStatus:DISCRETE(min = Gen2.PStatus.Standard max = Gen2.PStatus.LimitPMax start = Gen2.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Gen1.qStatus:DISCRETE(min = Gen1.QStatus.Standard max = Gen1.QStatus.GenerationMax start = Gen1.qStatus0 fixed = true protected = true ) \"Voltage regulation status: Standard, AbsorptionMax, GenerationMax\" type: enumeration(Standard, AbsorptionMax, GenerationMax) Gen1.pStatus:DISCRETE(min = Gen1.PStatus.Standard max = Gen1.PStatus.LimitPMax start = Gen1.PStatus.Standard fixed = true protected = true ) \"Active power / frequency regulation status: Standard, LimitPMin, LimitPMax\" type: enumeration(Standard, LimitPMin, LimitPMax) Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 178 * Number of states: 0 () * Number of discrete variables: 488 ($PRE.Gen1.limUQUp,Gen1.limUQUp,$PRE.Gen1.limUQDown,Gen1.limUQDown,$PRE.Gen2.limUQUp,Gen2.limUQUp,$PRE.Gen2.limUQDown,Gen2.limUQDown,$PRE.Gen3.limUQUp,Gen3.limUQUp,$PRE.Gen3.limUQDown,Gen3.limUQDown,$PRE.Gen6.limUQUp,Gen6.limUQUp,$PRE.Gen6.limUQDown,Gen6.limUQDown,$PRE.Gen8.limUQUp,Gen8.limUQUp,$PRE.Gen8.limUQDown,Gen8.limUQDown,$PRE.Load2.state,Load2.state,$PRE.Load3.state,Load3.state,$PRE.Load4.state,Load4.state,$PRE.Load5.state,Load5.state,$PRE.Load6.state,Load6.state,$PRE.Load9.state,Load9.state,$PRE.Load10.state,Load10.state,$PRE.Load11.state,Load11.state,$PRE.Load12.state,Load12.state,$PRE.Load13.state,Load13.state,$PRE.Load14.state,Load14.state,$PRE.LineB10B11.state,LineB10B11.state,$PRE.LineB12B13.state,LineB12B13.state,$PRE.LineB13B14.state,LineB13B14.state,$PRE.LineB1B2.state,LineB1B2.state,$PRE.LineB1B5.state,LineB1B5.state,$PRE.LineB2B3.state,LineB2B3.state,$PRE.LineB2B4.state,LineB2B4.state,$PRE.LineB2B5.state,LineB2B5.state,$PRE.LineB3B4.state,LineB3B4.state,$PRE.LineB4B5.state,LineB4B5.state,$PRE.LineB6B11.state,LineB6B11.state,$PRE.LineB6B12.state,LineB6B12.state,$PRE.LineB6B13.state,LineB6B13.state,$PRE.LineB7B8.state,LineB7B8.state,$PRE.LineB7B9.state,LineB7B9.state,$PRE.LineB9B10.state,LineB9B10.state,$PRE.LineB9B14.state,LineB9B14.state,$PRE.Tfo1.state,Tfo1.state,$PRE.Tfo2.state,Tfo2.state,$PRE.Tfo3.state,Tfo3.state,$PRE.Bank9.state,Bank9.state,$PRE.Gen8.state,Gen8.converter.u,Gen8.state,$PRE.Gen6.state,Gen6.converter.u,Gen6.state,$PRE.Gen3.state,Gen3.converter.u,Gen3.state,$PRE.Gen2.state,Gen2.converter.u,Gen2.state,$PRE.Gen1.state,Gen1.converter.u,Gen1.state,$PRE.Gen1.running.value,$PRE.Gen2.running.value,$PRE.Gen3.running.value,$PRE.Gen6.running.value,$PRE.Gen8.running.value,$PRE.Load2.running.value,$PRE.Load3.running.value,$PRE.Load4.running.value,$PRE.Load5.running.value,$PRE.Load6.running.value,$PRE.Load9.running.value,$PRE.Load10.running.value,$PRE.Load11.running.value,$PRE.Load12.running.value,$PRE.Load13.running.value,$PRE.Load14.running.value,$PRE.LineB10B11.running.value,$PRE.LineB12B13.running.value,$PRE.LineB13B14.running.value,$PRE.LineB1B2.switchOffSignal2.value,$PRE.LineB1B2.running.value,$PRE.LineB1B5.switchOffSignal2.value,$PRE.LineB1B5.running.value,$PRE.LineB2B3.running.value,$PRE.LineB2B4.running.value,$PRE.LineB2B5.switchOffSignal2.value,$PRE.LineB2B5.running.value,$PRE.LineB3B4.running.value,$PRE.LineB4B5.running.value,$PRE.LineB6B11.running.value,$PRE.LineB6B12.running.value,$PRE.LineB6B13.running.value,$PRE.LineB7B8.running.value,$PRE.LineB7B9.running.value,$PRE.LineB9B10.running.value,$PRE.LineB9B14.running.value,$PRE.Tfo1.running.value,$PRE.Tfo2.running.value,$PRE.Tfo3.running.value,$PRE.Bank9.running.value,$PRE.CLAB1B2.tThresholdReached,$PRE.CLAB1B2.tOrder,$PRE.CLAB2B5.tThresholdReached,$PRE.CLAB2B5.tOrder,$PRE.CLAB1B5.tThresholdReached,$PRE.CLAB1B5.tOrder,$PRE.CLAB1B5.order.value,$PRE.CLAB2B5.order.value,$PRE.CLAB1B2.order.value,$PRE.Gen8.qStatus,$PRE.Gen8.pStatus,$PRE.Gen6.qStatus,$PRE.Gen6.pStatus,$PRE.Gen3.qStatus,$PRE.Gen3.pStatus,$PRE.Gen2.qStatus,$PRE.Gen2.pStatus,$PRE.Gen1.qStatus,$PRE.Gen1.pStatus,CLAB1B5.tOrder,CLAB1B5.tThresholdReached,CLAB1B5.order.value,CLAB2B5.tOrder,CLAB2B5.tThresholdReached,CLAB2B5.order.value,CLAB1B2.tOrder,CLAB1B2.tThresholdReached,CLAB1B2.order.value,Bank9.running.value,Tfo3.running.value,Tfo2.running.value,Tfo1.running.value,LineB9B14.running.value,LineB9B10.running.value,LineB7B9.running.value,LineB7B8.running.value,LineB6B13.running.value,LineB6B12.running.value,LineB6B11.running.value,LineB4B5.running.value,LineB3B4.running.value,LineB2B5.running.value,LineB2B5.switchOffSignal2.value,LineB2B4.running.value,LineB2B3.running.value,LineB1B5.running.value,LineB1B5.switchOffSignal2.value,LineB1B2.running.value,LineB1B2.switchOffSignal2.value,LineB13B14.running.value,LineB12B13.running.value,LineB10B11.running.value,Load14.running.value,Load13.running.value,Load12.running.value,Load11.running.value,Load10.running.value,Load9.running.value,Load6.running.value,Load5.running.value,Load4.running.value,Load3.running.value,Load2.running.value,Gen8.qStatus,Gen8.pStatus,Gen8.running.value,Gen6.qStatus,Gen6.pStatus,Gen6.running.value,Gen3.qStatus,Gen3.pStatus,Gen3.running.value,Gen2.qStatus,Gen2.pStatus,Gen2.running.value,Gen1.qStatus,Gen1.pStatus,Gen1.running.value,$whenCondition2,$whenCondition1,$whenCondition4,$whenCondition3,$whenCondition6,$whenCondition5,$whenCondition7,$whenCondition9,$whenCondition8,$whenCondition10,$whenCondition12,$whenCondition11,$whenCondition13,$whenCondition15,$whenCondition14,$whenCondition16,$whenCondition18,$whenCondition17,$whenCondition19,$whenCondition21,$whenCondition20,$whenCondition22,$whenCondition24,$whenCondition23,$whenCondition25,$whenCondition27,$whenCondition26,$whenCondition28,$whenCondition30,$whenCondition29,$whenCondition31,$whenCondition33,$whenCondition32,$whenCondition34,$whenCondition36,$whenCondition35,$whenCondition37,$whenCondition39,$whenCondition38,$whenCondition40,$whenCondition42,$whenCondition41,$whenCondition43,$whenCondition45,$whenCondition44,$whenCondition46,$whenCondition48,$whenCondition47,$whenCondition49,$whenCondition51,$whenCondition50,$whenCondition52,$whenCondition54,$whenCondition53,$whenCondition56,$whenCondition55,$whenCondition58,$whenCondition57,$whenCondition59,$whenCondition61,$whenCondition60,$whenCondition62,$whenCondition64,$whenCondition63,$whenCondition66,$whenCondition65,$whenCondition68,$whenCondition67,$whenCondition70,$whenCondition69,$whenCondition72,$whenCondition71,$whenCondition73,$whenCondition75,$whenCondition74,$whenCondition76,$whenCondition78,$whenCondition77,$whenCondition79,$whenCondition81,$whenCondition80,$whenCondition82,$whenCondition84,$whenCondition83,$whenCondition85,$whenCondition87,$whenCondition86,$whenCondition88,$whenCondition90,$whenCondition89,$whenCondition91,$whenCondition93,$whenCondition92,$whenCondition94,$whenCondition96,$whenCondition95,$whenCondition97,$whenCondition99,$whenCondition98,$whenCondition100,$whenCondition102,$whenCondition101,$whenCondition103,$whenCondition105,$whenCondition104,$whenCondition106,$whenCondition108,$whenCondition107,$whenCondition109,$whenCondition111,$whenCondition110,$whenCondition112,$whenCondition114,$whenCondition113,$whenCondition115,$whenCondition117,$whenCondition116,$whenCondition121,$whenCondition120,$whenCondition119,$whenCondition118,$whenCondition126,$whenCondition125,$whenCondition124,$whenCondition123,$whenCondition122,$whenCondition127,$whenCondition129,$whenCondition128,$whenCondition133,$whenCondition132,$whenCondition131,$whenCondition130,$whenCondition138,$whenCondition137,$whenCondition136,$whenCondition135,$whenCondition134,$whenCondition139,$whenCondition141,$whenCondition140,$whenCondition145,$whenCondition144,$whenCondition143,$whenCondition142,$whenCondition150,$whenCondition149,$whenCondition148,$whenCondition147,$whenCondition146,$whenCondition151,$whenCondition153,$whenCondition152,$whenCondition157,$whenCondition156,$whenCondition155,$whenCondition154,$whenCondition162,$whenCondition161,$whenCondition160,$whenCondition159,$whenCondition158,$whenCondition163,$whenCondition165,$whenCondition164,$whenCondition169,$whenCondition168,$whenCondition167,$whenCondition166,$whenCondition174,$whenCondition173,$whenCondition172,$whenCondition171,$whenCondition170,$whenCondition177,$whenCondition176,$whenCondition175,$whenCondition180,$whenCondition179,$whenCondition178,$whenCondition183,$whenCondition182,$whenCondition181,$whenCondition186,$whenCondition185,$whenCondition184,$whenCondition189,$whenCondition188,$whenCondition187,$whenCondition190,$whenCondition191,$whenCondition192,Bank9.switchOffSignal2.value,Bank9.switchOffSignal1.value,Tfo3.switchOffSignal2.value,Tfo3.switchOffSignal1.value,Tfo2.switchOffSignal2.value,Tfo2.switchOffSignal1.value,Tfo1.switchOffSignal2.value,Tfo1.switchOffSignal1.value,LineB9B14.switchOffSignal2.value,LineB9B14.switchOffSignal1.value,LineB9B10.switchOffSignal2.value,LineB9B10.switchOffSignal1.value,LineB7B9.switchOffSignal2.value,LineB7B9.switchOffSignal1.value,LineB7B8.switchOffSignal2.value,LineB7B8.switchOffSignal1.value,LineB6B13.switchOffSignal2.value,LineB6B13.switchOffSignal1.value,LineB6B12.switchOffSignal2.value,LineB6B12.switchOffSignal1.value,LineB6B11.switchOffSignal2.value,LineB6B11.switchOffSignal1.value,LineB4B5.switchOffSignal2.value,LineB4B5.switchOffSignal1.value,LineB3B4.switchOffSignal2.value,LineB3B4.switchOffSignal1.value,LineB2B5.switchOffSignal1.value,LineB2B4.switchOffSignal2.value,LineB2B4.switchOffSignal1.value,LineB2B3.switchOffSignal2.value,LineB2B3.switchOffSignal1.value,LineB1B2.switchOffSignal1.value,LineB1B5.switchOffSignal1.value,LineB13B14.switchOffSignal2.value,LineB13B14.switchOffSignal1.value,LineB12B13.switchOffSignal2.value,LineB12B13.switchOffSignal1.value,LineB10B11.switchOffSignal2.value,LineB10B11.switchOffSignal1.value,Load14.switchOffSignal2.value,Load14.switchOffSignal1.value,Load13.switchOffSignal2.value,Load13.switchOffSignal1.value,Load12.switchOffSignal2.value,Load12.switchOffSignal1.value,Load11.switchOffSignal2.value,Load11.switchOffSignal1.value,Load10.switchOffSignal2.value,Load10.switchOffSignal1.value,Load9.switchOffSignal2.value,Load9.switchOffSignal1.value,Load6.switchOffSignal2.value,Load6.switchOffSignal1.value,Load5.switchOffSignal2.value,Load5.switchOffSignal1.value,Load4.switchOffSignal2.value,Load4.switchOffSignal1.value,Load3.switchOffSignal2.value,Load3.switchOffSignal1.value,Load2.switchOffSignal2.value,Load2.switchOffSignal1.value,Gen8.switchOffSignal3.value,Gen8.switchOffSignal2.value,Gen8.switchOffSignal1.value,Gen6.switchOffSignal3.value,Gen6.switchOffSignal2.value,Gen6.switchOffSignal1.value,Gen3.switchOffSignal3.value,Gen3.switchOffSignal2.value,Gen3.switchOffSignal1.value,Gen2.switchOffSignal3.value,Gen2.switchOffSignal2.value,Gen2.switchOffSignal1.value,Gen1.switchOffSignal3.value,Gen1.switchOffSignal2.value,Gen1.switchOffSignal1.value,CLAB1B5.AutomatonExists.value,CLAB2B5.AutomatonExists.value,CLAB1B2.AutomatonExists.value) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (723): * Single equations (assignments): 722 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(126,71)} Notification: Performance of prepare postOptimizeDAE: time 0.00607/0.9056, allocations: 1.639 MB / 0.8193 GB, free: 4.406 MB / 0.6387 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.002574/0.9082, allocations: 0.5517 MB / 0.8198 GB, free: 3.852 MB / 0.6387 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.02812/0.9363, allocations: 9.579 MB / 0.8292 GB, free: 10.18 MB / 0.6544 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.0001369/0.9364, allocations: 35.81 kB / 0.8292 GB, free: 10.14 MB / 0.6544 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.434e-05/0.9364, allocations: 4 kB / 0.8292 GB, free: 10.14 MB / 0.6544 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001772/0.9382, allocations: 0.5753 MB / 0.8298 GB, free: 9.543 MB / 0.6544 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.002017/0.9402, allocations: 199.8 kB / 0.8299 GB, free: 9.348 MB / 0.6544 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.005702/0.9459, allocations: 427.5 kB / 0.8304 GB, free: 8.93 MB / 0.6544 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.003213/0.9491, allocations: 0.8203 MB / 0.8312 GB, free: 8.105 MB / 0.6544 GB Notification: Performance of postOpt createDAEmodeBDAE (simulation): time 0.03039/0.9795, allocations: 9.385 MB / 0.8403 GB, free: 14.62 MB / 0.67 GB Notification: Performance of postOpt symbolicJacobianDAE (simulation): time 0.02837/1.008, allocations: 10.53 MB / 0.8506 GB, free: 3.988 MB / 0.67 GB Notification: Performance of postOpt setEvaluationStage (simulation): time 0.007132/1.015, allocations: 2.896 MB / 0.8534 GB, free: 1.07 MB / 0.67 GB Notification: Performance of sorting global known variables: time 0.003015/1.018, allocations: 1.466 MB / 0.8549 GB, free: 15.61 MB / 0.6856 GB Notification: Performance of Backend: time 6.02e-07/1.018, allocations: 0 / 0.8549 GB, free: 15.61 MB / 0.6856 GB Notification: Performance of simCode: created initialization part: time 0.02342/1.041, allocations: 5.443 MB / 0.8602 GB, free: 10.16 MB / 0.6856 GB Notification: Performance of SimCode: time 0.02262/1.064, allocations: 11.45 MB / 0.8714 GB, free: 14.71 MB / 0.7012 GB [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 2: LineB1B2.terminal1.V.re == 0.0 and LineB1B2.terminal1.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 5: LineB1B2.terminal2.V.re == 0.0 and LineB1B2.terminal2.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 8: LineB2B3.terminal2.V.re == 0.0 and LineB2B3.terminal2.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 11: LineB6B12.terminal2.V.re == 0.0 and LineB6B12.terminal2.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 14: Bus8.terminal.V.re == 0.0 and Bus8.terminal.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 25: Tfo2.terminal1.V.re == 0.0 and Tfo2.terminal1.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 30: LineB4B5.terminal1.V.re == 0.0 and LineB4B5.terminal1.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 39: LineB9B10.terminal2.V.re == 0.0 and LineB9B10.terminal2.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 44: LineB10B11.terminal2.V.re == 0.0 and LineB10B11.terminal2.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 49: Bus11.terminal.V.re == 0.0 and Bus11.terminal.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 54: LineB6B12.terminal1.V.re == 0.0 and LineB6B12.terminal1.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 59: Bus13.terminal.V.re == 0.0 and Bus13.terminal.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 64: LineB13B14.terminal2.V.re == 0.0 and LineB13B14.terminal2.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 69: LineB7B9.terminal2.V.re == 0.0 and LineB7B9.terminal2.V.im == 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 76: CLAB1B5.IMonitored.value > CLAB1B5.IMax and CLAB1B5.Running and pre(CLAB1B5.order.value) <> CLAB1B5.OrderToEmit. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 77: CLAB1B5.IMonitored.value < CLAB1B5.IMax and pre(CLAB1B5.tThresholdReached) <> 1e60 and pre(CLAB1B5.order.value) <> CLAB1B5.OrderToEmit. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 79: CLAB2B5.IMonitored.value > CLAB2B5.IMax and CLAB2B5.Running and pre(CLAB2B5.order.value) <> CLAB2B5.OrderToEmit. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 80: CLAB2B5.IMonitored.value < CLAB2B5.IMax and pre(CLAB2B5.tThresholdReached) <> 1e60 and pre(CLAB2B5.order.value) <> CLAB2B5.OrderToEmit. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 82: CLAB1B2.IMonitored.value > CLAB1B2.IMax and CLAB1B2.Running and pre(CLAB1B2.order.value) <> CLAB1B2.OrderToEmit. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 83: CLAB1B2.IMonitored.value < CLAB1B2.IMax and pre(CLAB1B2.tThresholdReached) <> 1e60 and pre(CLAB1B2.order.value) <> CLAB1B2.OrderToEmit. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 84: Gen8.PGenRawPu > Gen8.PMinPu and pre(Gen8.pStatus) == Gen8.PStatus.LimitPMin. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 85: Gen8.PGenRawPu < Gen8.PMaxPu and pre(Gen8.pStatus) == Gen8.PStatus.LimitPMax. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 86: Gen8.SGenPu.im + Gen8.QDeadBandPu <= Gen8.QMinPu and Gen8.UPu - Gen8.UDeadBandPu > Gen8.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 87: Gen8.SGenPu.im - Gen8.QDeadBandPu >= Gen8.QMaxPu and Gen8.UPu + Gen8.UDeadBandPu < Gen8.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 88: Gen8.SGenPu.im + Gen8.QDeadBandPu <= Gen8.QMinPu and Gen8.UPu == Gen8.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 91: (Gen8.SGenPu.im - Gen8.QDeadBandPu > Gen8.QMinPu or Gen8.UPu + Gen8.UDeadBandPu < Gen8.URef0Pu) and (Gen8.SGenPu.im + Gen8.QDeadBandPu < Gen8.QMaxPu or Gen8.UPu - Gen8.UDeadBandPu > Gen8.URef0Pu). [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 92: Gen6.PGenRawPu > Gen6.PMinPu and pre(Gen6.pStatus) == Gen6.PStatus.LimitPMin. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 93: Gen6.PGenRawPu < Gen6.PMaxPu and pre(Gen6.pStatus) == Gen6.PStatus.LimitPMax. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 94: Gen6.SGenPu.im + Gen6.QDeadBandPu <= Gen6.QMinPu and Gen6.UPu - Gen6.UDeadBandPu > Gen6.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 95: Gen6.SGenPu.im - Gen6.QDeadBandPu >= Gen6.QMaxPu and Gen6.UPu + Gen6.UDeadBandPu < Gen6.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 96: Gen6.SGenPu.im + Gen6.QDeadBandPu <= Gen6.QMinPu and Gen6.UPu == Gen6.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 99: (Gen6.SGenPu.im - Gen6.QDeadBandPu > Gen6.QMinPu or Gen6.UPu + Gen6.UDeadBandPu < Gen6.URef0Pu) and (Gen6.SGenPu.im + Gen6.QDeadBandPu < Gen6.QMaxPu or Gen6.UPu - Gen6.UDeadBandPu > Gen6.URef0Pu). [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 100: Gen3.PGenRawPu > Gen3.PMinPu and pre(Gen3.pStatus) == Gen3.PStatus.LimitPMin. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 101: Gen3.PGenRawPu < Gen3.PMaxPu and pre(Gen3.pStatus) == Gen3.PStatus.LimitPMax. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 102: Gen3.SGenPu.im + Gen3.QDeadBandPu <= Gen3.QMinPu and Gen3.UPu - Gen3.UDeadBandPu > Gen3.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 103: Gen3.SGenPu.im - Gen3.QDeadBandPu >= Gen3.QMaxPu and Gen3.UPu + Gen3.UDeadBandPu < Gen3.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 104: Gen3.SGenPu.im + Gen3.QDeadBandPu <= Gen3.QMinPu and Gen3.UPu == Gen3.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 107: (Gen3.SGenPu.im - Gen3.QDeadBandPu > Gen3.QMinPu or Gen3.UPu + Gen3.UDeadBandPu < Gen3.URef0Pu) and (Gen3.SGenPu.im + Gen3.QDeadBandPu < Gen3.QMaxPu or Gen3.UPu - Gen3.UDeadBandPu > Gen3.URef0Pu). [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 108: Gen2.PGenRawPu > Gen2.PMinPu and pre(Gen2.pStatus) == Gen2.PStatus.LimitPMin. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 109: Gen2.PGenRawPu < Gen2.PMaxPu and pre(Gen2.pStatus) == Gen2.PStatus.LimitPMax. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 110: Gen2.SGenPu.im + Gen2.QDeadBandPu <= Gen2.QMinPu and Gen2.UPu - Gen2.UDeadBandPu > Gen2.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 111: Gen2.SGenPu.im - Gen2.QDeadBandPu >= Gen2.QMaxPu and Gen2.UPu + Gen2.UDeadBandPu < Gen2.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 112: Gen2.SGenPu.im + Gen2.QDeadBandPu <= Gen2.QMinPu and Gen2.UPu == Gen2.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 115: (Gen2.SGenPu.im - Gen2.QDeadBandPu > Gen2.QMinPu or Gen2.UPu + Gen2.UDeadBandPu < Gen2.URef0Pu) and (Gen2.SGenPu.im + Gen2.QDeadBandPu < Gen2.QMaxPu or Gen2.UPu - Gen2.UDeadBandPu > Gen2.URef0Pu). [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 116: Gen1.PGenRawPu > Gen1.PMinPu and pre(Gen1.pStatus) == Gen1.PStatus.LimitPMin. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 117: Gen1.PGenRawPu < Gen1.PMaxPu and pre(Gen1.pStatus) == Gen1.PStatus.LimitPMax. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 118: Gen1.SGenPu.im + Gen1.QDeadBandPu <= Gen1.QMinPu and Gen1.UPu - Gen1.UDeadBandPu > Gen1.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 119: Gen1.SGenPu.im - Gen1.QDeadBandPu >= Gen1.QMaxPu and Gen1.UPu + Gen1.UDeadBandPu < Gen1.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 120: Gen1.SGenPu.im + Gen1.QDeadBandPu <= Gen1.QMinPu and Gen1.UPu == Gen1.URef0Pu. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 123: (Gen1.SGenPu.im - Gen1.QDeadBandPu > Gen1.QMinPu or Gen1.UPu + Gen1.UDeadBandPu < Gen1.URef0Pu) and (Gen1.SGenPu.im + Gen1.QDeadBandPu < Gen1.QMaxPu or Gen1.UPu - Gen1.UDeadBandPu > Gen1.URef0Pu). [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 124: CLAB1B2.tThresholdReached <> 1e60 and CLAB1B2.tOrder == 1e60 and der(CLAB1B2.IMonitored.value) < 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 125: CLAB2B5.tThresholdReached <> 1e60 and CLAB2B5.tOrder == 1e60 and der(CLAB2B5.IMonitored.value) < 0.0. [CodegenCpp.tpl:12254:11-12254:11:writable] Error: Template error: Unsupported zero crossing at 126: CLAB1B5.tThresholdReached <> 1e60 and CLAB1B5.tOrder == 1e60 and der(CLAB1B5.IMonitored.value) < 0.0. Error: Internal error SimCode DAEmode: The model Dynawo.Examples.IEEE14.TestCases.IEEE14CLA could not be translated " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 4.595040030995733] Failed to read output from testmodel.py, exit status != 0: 1.517236062005395 1.525840366 0.999620918 Calling exit ...