Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Chemical_master_Chemical.Examples.SimpleReactionsWithJunction2.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001626/0.001626, allocations: 116.7 kB / 17.13 MB, free: 5.945 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001663/0.001663, allocations: 209.5 kB / 20.09 MB, free: 2.996 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.473/1.473, allocations: 230.6 MB / 253.5 MB, free: 15.12 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo): time 0.1377/0.1377, allocations: 23.91 MB / 333.4 MB, free: 1.168 MB / 254.1 MB " [Timeout remaining time 180] Using package Chemical with version 2.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Chemical.Examples.SimpleReactionsWithJunction2,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Chemical_master_Chemical.Examples.SimpleReactionsWithJunction2") translateModel(Chemical.Examples.SimpleReactionsWithJunction2,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Chemical_master_Chemical.Examples.SimpleReactionsWithJunction2") [Timeout 660] "Notification: Chemical requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002051/0.002051, allocations: 80.25 kB / 467.2 MB, free: 30.55 MB / 350.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09103/0.09308, allocations: 59.84 MB / 0.5147 GB, free: 12.39 MB / 382.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1098:7-1098:40:writable] Warning: An inner declaration for outer component dropOfCommons could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Processes.mo:1098:7-1098:40:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"dropOfCommons\" component but an inner \"dropOfCommons\" component is not defined. Use Chemical.DropOfCommons in your model to specify system properties. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1697:7-1697:66:writable] Warning: An inner declaration for outer component system could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1697:7-1697:66:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer \"system\" component but an inner \"system\" component is not defined. For simulation drag Modelica.Fluid.System into your model to specify system properties. Notification: Performance of NFInst.instantiate(Chemical.Examples.SimpleReactionsWithJunction2): time 0.052/0.1451, allocations: 36.73 MB / 0.5506 GB, free: 7.656 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.01821/0.1633, allocations: 11.24 MB / 0.5616 GB, free: 12.38 MB / 430.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.001828/0.1651, allocations: 63.69 kB / 0.5616 GB, free: 12.31 MB / 430.1 MB Notification: Performance of NFTyping.typeComponents: time 0.004777/0.1699, allocations: 2.16 MB / 0.5637 GB, free: 10.14 MB / 430.1 MB Notification: Performance of NFTyping.typeBindings: time 0.003741/0.1736, allocations: 1.536 MB / 0.5652 GB, free: 8.594 MB / 430.1 MB Notification: Performance of NFTyping.typeClassSections: time 0.007558/0.1812, allocations: 4.031 MB / 0.5692 GB, free: 4.547 MB / 430.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Chemical master/Interfaces.mo:1311:3-1311:46:writable] Error: Parameter r.nextProducts[1].data.MM has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0006659/0.1819, allocations: 298.5 kB / 0.5694 GB, free: 4.254 MB / 430.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 2.688384295994183] Failed to read output from testmodel.py, exit status != 0: 0.18819287398946472 0.202123449 -1.0 Calling exit ...