Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_12_Buildings.Templates.Components.Validation.Pumps.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo): time 0.001577/0.001577, allocations: 111.7 kB / 17.13 MB, free: 5.926 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo): time 0.001677/0.001677, allocations: 204 kB / 20.09 MB, free: 2.977 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo): time 1.456/1.456, allocations: 230.6 MB / 253.5 MB, free: 15.09 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo): time 2.831/2.831, allocations: 0.49 GB / 0.7923 GB, free: 1.266 MB / 0.6231 GB " [Timeout remaining time 176] Using package Buildings with version 12.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/package.mo) Using package Modelica with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.1.0+maint.om/package.mo) Using package Complex with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.1.0+maint.om/package.mo) Using package ModelicaServices with version 4.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.1.0+maint.om/package.mo) Running command: translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_12_Buildings.Templates.Components.Validation.Pumps") translateModel(Buildings.Templates.Components.Validation.Pumps,tolerance=1e-06,outputFormat="mat",numberOfIntervals=2500,variableFilter="time|pum1.bus.y1|pum2.bus.y1|pum1.m_flow|pum2.m_flow|datPum.m_flow_nominal|res.m_flow|res.m_flow_nominal|pumMul.bus.y1.1.|pumMul.bus.y1.2.|pumMul.pum.1..m_flow|pumMul.pum.2..m_flow|pumMul.m_flow_nominal.1.|pumMul.m_flow_nominal.2.|resMul.m_flow|resMul.m_flow_nominal|pumMulCst.bus.y1.1.|pumMulCst.bus.y1.2.|pumMulCst.pum.1..m_flow|pumMulCst.pum.2..m_flow|pumMulCst.m_flow_nominal.1.|pumMulCst.m_flow_nominal.2.|resMulCst.m_flow|resMulCst.m_flow_nominal|pumMulDed.bus.y1.1.|pumMulDed.bus.y1.2.|pumMulDed.pum.1..m_flow|pumMulDed.pum.2..m_flow|pumMulDed.m_flow_nominal.1.|pumMulDed.m_flow_nominal.2.|resMulDed.m_flow|resMulDed.m_flow_nominal",fileNamePrefix="Buildings_12_Buildings.Templates.Components.Validation.Pumps") [Timeout 300] "Notification: Buildings requested package Modelica of version 4.0.0. Modelica 4.1.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002211/0.002211, allocations: 63.89 kB / 1.15 GB, free: 14.84 MB / 0.9356 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8904/0.8926, allocations: 176.1 MB / 1.322 GB, free: 25.04 MB / 1.061 GB Notification: Performance of NFInst.instantiate(Buildings.Templates.Components.Validation.Pumps): time 0.4776/1.37, allocations: 446.9 MB / 1.758 GB, free: 9.492 MB / 1.436 GB Notification: Performance of NFInst.instExpressions: time 0.1504/1.521, allocations: 97.52 MB / 1.854 GB, free: 7.73 MB / 1.529 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01817/1.539, allocations: 0.7284 MB / 1.854 GB, free: 6.996 MB / 1.529 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/Characteristics/flowParameters.mo:5:3-6:57:writable] Error: Dimension 1 of 'V_flow' could not be deduced from the component's binding equation 'datPumMul.per.pressure.V_flow'. Notification: Performance of FrontEnd: time 0.003342/1.542, allocations: 1.277 MB / 1.856 GB, free: 5.715 MB / 1.529 GB " [Timeout remaining time 298] [Calling sys.exit(0), Time elapsed: 7.517611315008253] Failed to read output from testmodel.py, exit status != 0: 1.5497495839954354 1.561888294 -1.0 Calling exit ...