Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=2e+07 stopTime=2.1e+07 tolerance=1e-06 numberOfIntervals=277 stepSize=3610.11 Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Photovoltaics.Check.Check_DataSheetBasedPV -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/GHI_Hamburg_3600s_TMY.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/GHI_Hamburg_3600s_TMY.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/Temperature_Hamburg-Fuhlsbuettel_3600s_01012012_31122012.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0179464s reading init.xml | | | | | | 0.00181155s reading info.xml | | | | | | 0.000148869s [ 0.3%] pre-initialization | | | | | | 0.0552949s [ 98.4%] initialization | | | | | | 9.31e-07s [ 0.0%] steps | | | | | | 3.251e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 5.042e-06s [ 0.0%] event-handling | | | | | | 0.000404477s [ 0.7%] overhead | | | | | | 0.000345333s [ 0.6%] simulation | | | | | | 0.0562028s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 277 steps taken | | | | | | 277 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.