Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=672 stepSize=900 Regular simulation: ./TransiEnt_TransiEnt.Consumer.Heat.SpaceHeating.Check.ComputeDesignHeatLoad_EN12831 -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/Temperature_Hamburg-Billwerder_900s_01012012_31122012.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STDOUT | info | TILMedia-Error(ComputeDesignHeatLoad_EN12831.roomFloorHeating.waterOutState, HelmholtzModel::rho_pT, mediumPointerID=7): Temperature T=39856.2 above Tmax=20000 LOG_STDOUT | info | TILMedia-Error(ComputeDesignHeatLoad_EN12831.roomFloorHeating.waterOutState, HelmholtzModel::rho_pT, mediumPointerID=7): Temperature T=39856.2 above Tmax=20000 LOG_ASSERT | debug | Solving non-linear system 586 failed at time=3.47029269726068. | | | | For more information please use -lv LOG_NLS. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.021555s reading init.xml | | | | | | 0.00140798s reading info.xml | | | | | | 0.000208671s [ 0.0%] pre-initialization | | | | | | 0.0569648s [ 1.1%] initialization | | | | | | 0.000130825s [ 0.0%] steps | | | | | | 0.00235034s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00050218s [ 0.0%] event-handling | | | | | | 0.0011508s [ 0.0%] overhead | | | | | | 5.15963s [ 98.8%] simulation | | | | | | 5.22094s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 630 steps taken | | | | | | 945 calls of functionODE | | | | | | 185 evaluations of jacobian | | | | | | 49 error test failures | | | | | | 18 convergence test failures | | | | | | 2.1345s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.