Environment - simulationEnvironment: startTime=0 stopTime=500 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.2 Regular simulation: ./ThermoPower_ThermoPower.Test.WaterComponents.TestExpansionTankIdeal -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00402596s reading init.xml | | | | | | 0.000301295s reading info.xml | | | | | | 7.8056e-05s [ 0.0%] pre-initialization | | | | | | 0.0368091s [ 13.6%] initialization | | | | | | 3.8392e-05s [ 0.0%] steps | | | | | | 0.00126428s [ 0.5%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000415738s [ 0.2%] event-handling | | | | | | 0.00895125s [ 3.3%] overhead | | | | | | 0.223719s [ 82.5%] simulation | | | | | | 0.271276s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 173 steps taken | | | | | | 232 calls of functionODE | | | | | | 44 evaluations of jacobian | | | | | | 6 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00678715s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.