Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-08 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./IDEAS_dev_IDEAS.Fluid.Movers.Validation.Pump_Nrpm_stratos -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump3.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump4.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((forcedPump5.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0492594s reading init.xml | | | | | | 0.00371104s reading info.xml | | | | | | 0.000122379s [ 0.2%] pre-initialization | | | | | | 0.000569709s [ 1.1%] initialization | | | | | | 4.699e-06s [ 0.0%] steps | | | | | | 0.00245966s [ 4.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00041316s [ 0.8%] event-handling | | | | | | 0.0142753s [ 27.6%] overhead | | | | | | 0.0338478s [ 65.5%] simulation | | | | | | 0.0516927s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 697 steps taken | | | | | | 935 calls of functionODE | | | | | | 177 evaluations of jacobian | | | | | | 54 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000165138s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.