Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Dynawo_1.6.1_Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B1.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001435/0.001435, allocations: 105.8 kB / 16.4 MB, free: 6.504 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001605/0.001605, allocations: 198.7 kB / 19.35 MB, free: 3.73 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.54/1.54, allocations: 205.1 MB / 227.2 MB, free: 12.14 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/package.mo): time 0.3182/0.3182, allocations: 71.8 MB / 348.4 MB, free: 1.949 MB / 286.1 MB " [Timeout remaining time 179] Using package Dynawo with version 1.6.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_1.6.1_Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B1") translateModel(Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B1,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Dynawo_1.6.1_Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B1") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00315/0.00315, allocations: 73.78 kB / 497.5 MB, free: 2.34 MB / 366.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3902/0.3934, allocations: 64.3 MB / 0.5487 GB, free: 2.84 MB / 398.1 MB Notification: Performance of NFInst.instantiate(Dynawo.Examples.SMIB.Standard.GovSteam1ExcIEEEST4BPssIEEE2B1): time 0.01256/0.406, allocations: 8.826 MB / 0.5573 GB, free: 11.79 MB / 414.1 MB Notification: Performance of NFInst.instExpressions: time 0.01291/0.419, allocations: 4.837 MB / 0.562 GB, free: 7.828 MB / 414.1 MB Notification: Performance of NFInst.updateImplicitVariability: time 0.002634/0.4217, allocations: 37.38 kB / 0.562 GB, free: 7.816 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:20:3-20:98:writable] Warning: Connector switchOffSignal1 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:21:3-21:125:writable] Warning: Connector switchOffSignal2 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:22:3-22:125:writable] Warning: Connector switchOffSignal3 is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:24:3-24:105:writable] Warning: Connector running is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:24:3-24:104:writable] Warning: Connector omegaRefPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:25:3-25:94:writable] Warning: Connector PmPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:26:3-26:125:writable] Warning: Connector efdPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:29:3-29:96:writable] Warning: Connector omegaPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:42:3-42:108:writable] Warning: Connector UStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:43:3-43:115:writable] Warning: Connector IStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:44:3-44:116:writable] Warning: Connector QStatorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:45:3-45:126:writable] Warning: Connector QStatorPuQNom is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:46:3-46:123:writable] Warning: Connector IRotorPu is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/GeneratorSynchronous.mo:47:3-47:95:writable] Warning: Connector thetaInternal is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SetPoint.mo:17:3-17:75:writable] Warning: Connector setPoint is not balanced: The number of potential variables (1) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.001753/0.4235, allocations: 454.1 kB / 0.5625 GB, free: 7.457 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Strings.mo:139:3-175:14:writable] Warning: Pure function 'Modelica.Utilities.Strings.isEmpty' contains a call to impure function 'Modelica.Utilities.Strings.Advanced.skipWhiteSpace'. Notification: Performance of NFTyping.typeBindings: time 0.002639/0.4261, allocations: 0.5894 MB / 0.563 GB, free: 6.957 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Examples/SMIB/Standard/GovSteam1ExcIEEEST4BPssIEEE2B1.mo:115:3-115:54:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Examples/SMIB/Standard/GovSteam1ExcIEEEST4BPssIEEE2B1.mo:116:3-116:54:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:133:3-133:117:writable] Warning: In relation generatorSynchronous.SNom <> generatorSynchronous.PNomAlt, <> on Real numbers is only allowed inside functions. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:40:5-44:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal2' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Controls/Basics/SwitchOff/SwitchOffLogic.mo:34:5-38:13:writable] Warning: Conditional component 'switchOffSignal3' is used in a non-connect context. Notification: Performance of NFTyping.typeClassSections: time 0.004325/0.4305, allocations: 1.972 MB / 0.565 GB, free: 5.02 MB / 414.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Dynawo 1.6.1-maint.1.6.x/Electrical/Machines/OmegaRef/BaseClasses/BaseGeneratorSynchronous.mo:51:3-51:114:writable] Error: Parameter generatorSynchronous.MdPPuEfd has neither value nor start value, and is fixed during initialization (fixed=true). Notification: Performance of FrontEnd: time 0.0002478/0.4307, allocations: 115.4 kB / 0.5651 GB, free: 4.906 MB / 414.1 MB " [Timeout remaining time 660] [Calling sys.exit(0), Time elapsed: 3.329023754224181] Failed to read output from testmodel.py, exit status != 0: 0.4403105489909649 0.45158752700000004 -1.0 Calling exit ...