Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./Buildings_maint.7.0.x_Buildings.Fluid.FixedResistances.BaseClasses.Validation.PlugFlowCore -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00319172s reading init.xml | | | | | | 0.000349075s reading info.xml | | | | | | 8.1262e-05s [ 0.3%] pre-initialization | | | | | | 0.000222387s [ 0.8%] initialization | | | | | | 2.895e-06s [ 0.0%] steps | | | | | | 0.00131914s [ 5.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00468477s [ 17.7%] event-handling | | | | | | 0.00449581s [ 17.0%] overhead | | | | | | 0.0156509s [ 59.2%] simulation | | | | | | 0.0264571s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 463 steps taken | | | | | | 1148 calls of functionODE | | | | | | 462 evaluations of jacobian | | | | | | 204 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00171097s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.