Environment - simulationEnvironment: startTime=1.87488e+07 stopTime=1.93536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer -abortSlowSimulation -alarm=400 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2024.11.18 22:22 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 08/06/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output OneZoneOneOutputVariableSummer.equEle.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 18748800.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00831794s reading init.xml | | | | | | 0.000631935s reading info.xml | | | | | | 7.0613e-05s [ 0.0%] pre-initialization | | | | | | 7.2023s [ 95.6%] initialization | | | | | | 5.08e-06s [ 0.0%] steps | | | | | | 0.00981754s [ 0.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.279998s [ 3.7%] event-handling | | | | | | 0.00582205s [ 0.1%] overhead | | | | | | 0.0383355s [ 0.5%] simulation | | | | | | 7.53635s [100.0%] total | | | | | events | | | | | | 504 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 9957 steps taken | | | | | | 13073 calls of functionODE | | | | | | 6057 evaluations of jacobian | | | | | | 259 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0157115s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.63sec EnergyPlus Completed Successfully.