Environment - simulationEnvironment: startTime=0 stopTime=259200 tolerance=1e-06 numberOfIntervals=2500 stepSize=103.68 Regular simulation: ./Buildings_latest_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SingleFamilyHouse.Radiator -abortSlowSimulation -alarm=800 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2024.12.18 00:39 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59403e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0186315s reading init.xml | | | | | | 0.00161375s reading info.xml | | | | | | 0.000607118s [ 0.0%] pre-initialization | | | | | | 7.09242s [ 94.5%] initialization | | | | | | 9.648e-06s [ 0.0%] steps | | | | | | 0.0206847s [ 0.3%] solver (excl. callbacks) | | | | | | 0.00285409s [ 0.0%] creating output-file | | | | | | 0.145593s [ 1.9%] event-handling | | | | | | 0.00910535s [ 0.1%] overhead | | | | | | 0.235894s [ 3.1%] simulation | | | | | | 7.50717s [100.0%] total | | | | | events | | | | | | 431 state events | | | | | | 6 time events | | | | | solver: dassl | | | | | | 11890 steps taken | | | | | | 17558 calls of functionODE | | | | | | 4742 evaluations of jacobian | | | | | | 161 error test failures | | | | | | 22 convergence test failures | | | | | | 0.154666s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.70sec EnergyPlus Completed Successfully.