Environment - simulationEnvironment: startTime=7.344e+06 stopTime=7.776e+06 tolerance=1e-07 numberOfIntervals=10643 stepSize=40.5901 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.Guideline36Spring -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.11.11 21:42 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/08/2017 Continuing Simulation at 01/08/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/15/2017 Continuing Simulation at 01/15/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/22/2017 Continuing Simulation at 01/22/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=01/29/2017 Continuing Simulation at 01/29/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/05/2017 Continuing Simulation at 02/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/12/2017 Continuing Simulation at 02/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/19/2017 Continuing Simulation at 02/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=02/26/2017 Continuing Simulation at 02/26/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/05/2017 Continuing Simulation at 03/05/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/12/2017 Continuing Simulation at 03/12/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/19/2017 Continuing Simulation at 03/19/2017 for SPAWN-RUNPERIOD Updating Shadowing Calculations, Start Date=03/26/2017 Continuing Simulation at 03/26/2017 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7344000.000000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -3.2842e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7344000.000000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -2.92234e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7344000.000000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -3.2842e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7344000.000000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -2.92234e-13" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 7344000.000000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -4.33235e-13" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 7344000.000004 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -3.38717e-13" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 7344000.000004 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -8.35e-09" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Sensors/VolumeFlowRate.mo:19:3-25:24:writable] | | | | The following assertion has been violated at time 7344000.000004 | | | | ((hvac.VOut1.V_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VOut1.V_flow, has value: -3.83152e-214" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7344162.360237 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -2.13231e-92" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7367700.000221 | | | | ((hvac.conVAV[1].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7367700.000221 | | | | ((hvac.conVAV[2].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7367700.000221 | | | | ((hvac.conVAV[2].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7367700.000221 | | | | ((hvac.conVAV[3].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7367700.000221 | | | | ((hvac.conVAV[4].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7367700.000221 | | | | ((hvac.conVAV[4].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7367700.000221 | | | | ((hvac.conVAV[5].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 7380896.363807 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -4.85107e-18" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 7380930.982200 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -4.99259e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 7380930.982200 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -7.21409e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7380930.982200 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.06264e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 7381016.192969 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -2.29006e-71" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 7412475.429860 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -2.65276e-13" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 7498891.665884 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -9.8706e-27" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 7498891.665884 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -8.77698e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 7498920.000000 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 1e5, has value: -2.05866e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 7625100.000153 | | | | ((hvac.conVAV[5].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.32239s reading init.xml | | | | | | 0.0265965s reading info.xml | | | | | | 0.00749394s [ 0.0%] pre-initialization | | | | | | 10.4031s [ 5.3%] initialization | | | | | | 0.00341881s [ 0.0%] steps | | | | | | 5.57899s [ 2.8%] solver (excl. callbacks) | | | | | | 1.55092s [ 0.8%] creating output-file | | | | | | 18.858s [ 9.6%] event-handling | | | | | | 0.385427s [ 0.2%] overhead | | | | | | 159.615s [ 81.3%] simulation | | | | | | 196.403s [100.0%] total | | | | | events | | | | | | 2278 state events | | | | | | 3601 time events | | | | | solver: dassl | | | | | | 104350 steps taken | | | | | | 133712 calls of functionODE | | | | | | 63210 evaluations of jacobian | | | | | | 1368 error test failures | | | | | | 51 convergence test failures | | | | | | 149.165s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 03min 8.98sec EnergyPlus Completed Successfully.