Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001753/0.00176, allocations: 105.6 kB / 16.4 MB, free: 6.5 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001943/0.001943, allocations: 198.7 kB / 19.35 MB, free: 3.73 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.611/1.611, allocations: 205.1 MB / 227.2 MB, free: 12.14 MB / 190.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.2938/0.2938, allocations: 54.95 MB / 331.6 MB, free: 2.746 MB / 270.1 MB " [Timeout remaining time 179] Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust") translateModel(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Annex60 requested package Modelica of version 3.2.2. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002218/0.002218, allocations: 69.3 kB / 464.9 MB, free: 328 kB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1361/0.1384, allocations: 59.59 MB / 0.5122 GB, free: 4.77 MB / 398.1 MB Notification: Performance of NFInst.instantiate(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACWithExhaust): time 1.265/1.404, allocations: 379.5 MB / 0.8829 GB, free: 15.53 MB / 0.6075 GB Notification: Performance of NFInst.instExpressions: time 0.07817/1.482, allocations: 46.81 MB / 0.9286 GB, free: 10.48 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01094/1.493, allocations: 175.1 kB / 0.9287 GB, free: 10.37 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Conversion/AirToOutlet.mo:92:3-94:60:writable] Warning: Connector bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Conversion/InletToAir.mo:76:3-78:60:writable] Warning: Connector bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01268/1.506, allocations: 2.924 MB / 0.9316 GB, free: 8.277 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Adaptors/HVAC.mo:48:16-48:66:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Adaptors/HVAC.mo:47:3-56:28:writable] Error: Type mismatch in binding 'quantity = fill(hvacAda.Medium.extraPropertiesNames, 3)', expected array dimensions [], got [3, 0]. Notification: Performance of FrontEnd: time 0.0003067/1.506, allocations: 41.69 kB / 0.9316 GB, free: 8.246 MB / 0.6231 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 4.556175642646849]