/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase_res.mat --tempDir=temp_ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase_fmu --startTime=0 --stopTime=60 --timeout=1200 --tolerance=1e-06 ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase_res.mat (bufferSize=1) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0/Boundaries/Internal/PartialVolume.mo:110:3-110:103:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance1.inlet.m_flow > volume.m_flow_assert)) --> "Negative massflow at Volume inlet" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0/Boundaries/Internal/PartialVolume.mo:110:3-110:103:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flowResistance3.inlet.m_flow > volume1.m_flow_assert)) --> "Negative massflow at Volume inlet" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0/Boundaries/Internal/PartialVolume.mo:111:3-111:106:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((mCV2.inlet.m_flow > volume.m_flow_assert)) --> "Positive massflow at Volume outlet" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream 1.1.0/Boundaries/Internal/PartialVolume.mo:111:3-111:106:writable] | | | | The following assertion has been violated at time 0.001000 | | | | ((mCV3.inlet.m_flow > volume1.m_flow_assert)) --> "Positive massflow at Volume outlet" LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ThermofluidStream_ThermofluidStream.HeatExchangers.Tests.ElementTwoPhase/ThermofluidStream_ThermofluidStream_HeatExchangers_Tests_ElementTwoPhase.fmutmp/sources/gc/memory_pool.c:100: pool_expand: Assertion `0 && "Attempt to allocate an unusually large memory. The memory management does not seem to be working as intended. Please create an issue on https://github.com/OpenModelica/OpenModelica/issues."` failed. LOG_STDOUT | warning | While solving non-linear system an assertion failed at time 12.131. | | | | | The non-linear solver tries to solve the problem that could take some time. | | | | | It could help to provide better start-values for the iteration variables. | | | | | For more information simulate with -lv LOG_NLS_V error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors