Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo", uses=false) Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,fileNamePrefix="ThermoPower_ThermoPower_PowerPlants_ElectricGeneratorGroup_Tests_Test_Generator_SE",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE,fileNamePrefix="ThermoPower_ThermoPower_PowerPlants_ElectricGeneratorGroup_Tests_Test_Generator_SE",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001615/0.001615, allocations: 113.8 kB / 17.06 MB, free: 6.004 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001676/0.001676, allocations: 189.4 kB / 18 MB, free: 5.086 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.441/1.441, allocations: 205.1 MB / 223.9 MB, free: 12.28 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo): time 0.3023/0.3023, allocations: 48.84 MB / 320.1 MB, free: 11.02 MB / 270.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00214/0.002141, allocations: 75.88 kB / 450 MB, free: 9.062 MB / 334.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1136/0.1157, allocations: 59.15 MB / 0.4972 GB, free: 13.78 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/PowerPlants.mo:18204:30-18204:37:writable] Error: Modified element Pn not found in class Grid. Notification: Performance of FrontEnd: time 0.2679/0.3837, allocations: 35.3 MB / 0.5317 GB, free: 6.492 MB / 414.1 MB