/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent_fmu --startTime=0 --stopTime=1 --timeout=50 --tolerance=1e-06 TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent.fmu info: model doesn't contain any continuous state info: Result file: model_res.mat (bufferSize=10) error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.Functions.ExchangerEffectiveness.Inverse.test_NTU_coCurrent/temp_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent_fmu/model-hdho7mhk/temp/0001_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent (logStatusError): Model error: Argument of log(1.0 - Eff * (1.0 + Cr)) was -2.22045e-16 should be > 0 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.Functions.ExchangerEffectiveness.Inverse.test_NTU_coCurrent/temp_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent_fmu/model-hdho7mhk/temp/0001_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent (logFmi2Call): fmi2GetReal: terminated by an assertion. error: [updateSignals] failed to fetch variable ramp1.y error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.Functions.ExchangerEffectiveness.Inverse.test_NTU_coCurrent/temp_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent_fmu/model-hdho7mhk/temp/0001_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent (logStatusError): Model error: Argument of log(1.0 - Eff * (1.0 + Cr)) was -2.22045e-16 should be > 0 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/TAeZoSysPro_testsuite_TAeZoSysPro_testsuite.HeatTransfer.Functions.ExchangerEffectiveness.Inverse.test_NTU_coCurrent/temp_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent_fmu/model-hdho7mhk/temp/0001_TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.TAeZoSysPro_testsuite_TAeZoSysPro_testsuite_HeatTransfer_Functions_ExchangerEffectiveness_Inverse_test_NTU_coCurrent" info: 0 warnings info: 6 errors