/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ScalableTestSuite_ScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_10_M_10_res.mat --tempDir=temp_ScalableTestSuite_ScalableTestSuite_Electrical_DistributionSystemDC_ScaledExperiments_DistributionSystemModelica_N_10_M_10_fmu --startTime=0 --stopTime=1 --stepSize=0.001 --timeout=300 --tolerance=1e-06 ScalableTestSuite_ScalableTestSuite_Electrical_DistributionSystemDC_ScaledExperiments_DistributionSystemModelica_N_10_M_10.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_10_M_10" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_10_M_10" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_10_M_10/model-dsd5dlpr" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ScalableTestSuite_ScalableTestSuite_Electrical_DistributionSystemDC_ScaledExperiments_DistributionSystemModelica_N_10_M_10.fmu - startTime: 0.000000 - stopTime: 1.000000 - tolerance: 0.000001 - stepSize: 0.001000 LOG_STDOUT | info | Using sparse solver for linear system 0, | | | | because density of 0.006 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | Using sparse solver for linear system 1, | | | | because density of 0.006 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. info: model doesn't contain any continuous state info: maximum step size for 'model.root': 0.001000 info: Result file: ScalableTestSuite_ScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_10_M_10_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 1000 NumRhsEvals = 1001 NumLinSolvSetups = 50 NumNonlinSolvIters = 1000 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors