/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_fmu --startTime=0 --stopTime=10 --timeout=50 --tolerance=1e-08 OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.oil.oilName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.A2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.A2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.B2T.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.B2T.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.P2A.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.P2A.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.P2B.MeteringTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest.valve4_3pos.P2B.MeteringTable.tableName will not be stored in the result file, because the signal type is not supported warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/OpenHydraulics_OpenHydraulics.DevelopmentTests.DirectionalValveTest/temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_fmu/model-4h774516/temp/0001_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest (logStatusWarning): The following assertion has been violated at time 0.001000 LOG_ASSERT | debug | Model error: Argument of sqrt((-restriction.dp) * constNeg) was -1.22211 should be >= 0 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/OpenHydraulics_OpenHydraulics.DevelopmentTests.DirectionalValveTest/temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_fmu/model-4h774516/temp/0001_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest" warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/OpenHydraulics_OpenHydraulics.DevelopmentTests.DirectionalValveTest/temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_fmu/model-4h774516/temp/0001_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest (logStatusWarning): The following assertion has been violated at time 0.001000 LOG_ASSERT | debug | Model error: Argument of sqrt((-restriction.dp) * constNeg) was -1.19702 should be >= 0 error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/OpenHydraulics_OpenHydraulics.DevelopmentTests.DirectionalValveTest/temp_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest_fmu/model-4h774516/temp/0001_OpenHydraulics_OpenHydraulics_DevelopmentTests_DirectionalValveTest (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable valve4_3pos.j4.volumeClosed.compressible info: Final Statistics for 'model.root': NumSteps = 45 NumRhsEvals = 79 NumLinSolvSetups = 18 NumNonlinSolvIters = 77 NumNonlinSolvConvFails = 1 NumErrTestFails = 5 info: 2 warnings info: 4 errors