/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ModelicaTest_3.2.3_ModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_StandardWater_res.mat --tempDir=temp_ModelicaTest_3_2_3_ModelicaTest_Fluid_TestExamplesVariants_BranchingDynamicPipes_StandardWater_fmu --startTime=0 --stopTime=10 --stepSize=0.002 --timeout=50 --tolerance=1e-06 ModelicaTest_3_2_3_ModelicaTest_Fluid_TestExamplesVariants_BranchingDynamicPipes_StandardWater.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_3.2.3_ModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_StandardWater" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_3.2.3_ModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_StandardWater" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_3.2.3_ModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_StandardWater/model-hr84mvbg" info: *** FMU Simulation Info *** - model: model (model exchange) - path: ModelicaTest_3_2_3_ModelicaTest_Fluid_TestExamplesVariants_BranchingDynamicPipes_StandardWater.fmu - startTime: 0.000000 - stopTime: 10.000000 - tolerance: 0.000001 - stepSize: 0.002000 error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_3.2.3_ModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_StandardWater/model-hr84mvbg/temp/0001_ModelicaTest_3_2_3_ModelicaTest_Fluid_TestExamplesVariants_BranchingDynamicPipes_StandardWater/logStatusError: /home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Media/Water/IF97_Utilities.mo:6433: Error in region computation of IF97 steam tables(p = 189240, h = -1.77603e+08) error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/ModelicaTest_3.2.3_ModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_StandardWater/model-hr84mvbg/temp/0001_ModelicaTest_3_2_3_ModelicaTest_Fluid_TestExamplesVariants_BranchingDynamicPipes_StandardWater/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.ModelicaTest_3_2_3_ModelicaTest_Fluid_TestExamplesVariants_BranchingDynamicPipes_StandardWater" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 5 errors