/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout_fmu --startTime=0 --stopTime=10000 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump3.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump4.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump5.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump6.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump7.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom_recomp.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom_recomp.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom_recomp.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_nom_recomp.powerTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_recomp.copTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_recomp.copTable.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_recomp.powerTable.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout.HP_recomp.powerTable.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Media/package.mo:5878:7-5882:3:writable] | | | | The following assertion has been violated at time 1.326000 | | | | ((HP_recomp.vol2.dynBal.medium.T >= 272.15 and HP_recomp.vol2.dynBal.medium.T <= 403.15)) --> " | | | | Temperature T (= 272.144 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". | | | | " error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatPumps.Examples.HeatPump_perfFromTout/temp_IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout_fmu/model-lkrvjnwr/temp/0001_IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Media/package.mo:5878:7-5882:3:writable] | | | | The following assertion has been violated at time 1.326000 | | | | ((HP_recomp.vol2.dynBal.medium.T >= 272.15 and HP_recomp.vol2.dynBal.medium.T <= 403.15)) --> " | | | | Temperature T (= 272.147 K) is not | | | | in the allowed range (272.15 K <= T <= 403.15 K) | | | | required from medium model "SimpleLiquidWater". | | | | " error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatPumps.Examples.HeatPump_perfFromTout/temp_IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout_fmu/model-lkrvjnwr/temp/0001_IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_perfFromTout (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable sim.weaBus.solBus[6].outputAngles info: Final Statistics for 'model.root': NumSteps = 1329 NumRhsEvals = 1333 NumLinSolvSetups = 69 NumNonlinSolvIters = 1332 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 4 errors