/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater_fmu --startTime=0 --stopTime=15000 --stepSize=6 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatPumps.Examples.HeatPump_AirWater" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatPumps.Examples.HeatPump_AirWater" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatPumps.Examples.HeatPump_AirWater/model-24pyxzle" info: *** FMU Simulation Info *** - model: model (model exchange) - path: IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.fmu - startTime: 0.000000 - stopTime: 15000.000000 - tolerance: 0.000001 - stepSize: 6.000000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 6.000000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P100.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P100.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P30.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P30.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P50.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P50.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P90.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.P90.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q100.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q100.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q30.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q30.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q50.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q50.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q90.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.IDEAS_IDEAS_Fluid_HeatPumps_Examples_HeatPump_AirWater.heater.heatSource.Q90.tableName will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 0 and h = 6, the error test failed repeatedly or with |h| = hmin. error: [doStepCVODE] CVode failed with flag = -3 warning: Bad return code at time 0.000000 error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 3 NumLinSolvSetups = 1 NumNonlinSolvIters = 2 NumNonlinSolvConvFails = 0 NumErrTestFails = 1 info: 3 warnings info: 2 errors