/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_ThreeWayValveMotor_fmu --startTime=0 --stopTime=100 --stepSize=0.04 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_ThreeWayValveMotor.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.Actuators.Valves.Simplified.Examples.ThreeWayValveMotor" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.Actuators.Valves.Simplified.Examples.ThreeWayValveMotor" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.Actuators.Valves.Simplified.Examples.ThreeWayValveMotor/model-uzcw1mr8" info: *** FMU Simulation Info *** - model: model (model exchange) - path: IDEAS_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_ThreeWayValveMotor.fmu - startTime: 0.000000 - stopTime: 100.000000 - tolerance: 0.000001 - stepSize: 0.040000 info: model doesn't contain any continuous state LOG_STDOUT | info | | | | | Warning: | | | | ======== | | | | It is recommended that the volume flow rate versus pressure relation | | | | of the fan or pump satisfies the minimum decrease condition | | | | | | | | (per.pressure.dp[i+1]-per.pressure.dp[i]) | | | | d[i] = ------------------------------------------------- < -0 | | | | (per.pressure.V_flow[i+1]-per.pressure.V_flow[i]) | | | | | | | | is | | | | d[1]=0 | | | | | | | | Otherwise, a solution to the equations may not exist if the fan or pump speed is reduced. | | | | In this situation, the solver will fail due to non-convergence and | | | | the simulation stops. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumpFlow1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 0.040000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 2500 NumRhsEvals = 2501 NumLinSolvSetups = 125 NumNonlinSolvIters = 2500 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors