/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Buildings_Components_BaseClasses_RadiativeHeatTransfer_Examples_LongwaveHeatTransfer_fmu --startTime=0 --stopTime=1e+06 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Buildings_Components_BaseClasses_RadiativeHeatTransfer_Examples_LongwaveHeatTransfer.fmu info: model doesn't contain any continuous state LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistribution.mo:84:3-89:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((max(zonLwDistLin.F1) < zonLwDistLin.FMax * 0.9 and zonLwDistLin.computeCarroll or zonLwDistLin.simVieFac)) --> "WARNING: In LongwaveHeatTransfer.zonLwDistLin: The computed view factor returned unexpected results. | | | | A simplified method is used. | | | | This may be caused by trying to model a non-physical geometry. | | | | Avoid this warning by setting simVieFac=true in the respective zone model. | | | | " LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/BaseClasses/RadiativeHeatTransfer/ZoneLwDistribution.mo:84:3-89:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((max(zonLwDist.F1) < zonLwDist.FMax * 0.9 and zonLwDist.computeCarroll or zonLwDist.simVieFac)) --> "WARNING: In LongwaveHeatTransfer.zonLwDist: The computed view factor returned unexpected results. | | | | A simplified method is used. | | | | This may be caused by trying to model a non-physical geometry. | | | | Avoid this warning by setting simVieFac=true in the respective zone model. | | | | " info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Buildings.Components.BaseClasses.RadiativeHeatTransfer.Examples.LongwaveHeatTransfer/temp_IDEAS_IDEAS_Buildings_Components_BaseClasses_RadiativeHeatTransfer_Examples_LongwaveHeatTransfer_fmu/model-savsd6kn/temp/0001_IDEAS_IDEAS_Buildings_Components_BaseClasses_RadiativeHeatTransfer_Examples_LongwaveHeatTransfer (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.IDEAS_IDEAS_Buildings_Components_BaseClasses_RadiativeHeatTransfer_Examples_LongwaveHeatTransfer"