/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase7_res.mat --tempDir=temp_Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7_fmu --startTime=0 --stopTime=5.184e+06 --stepSize=60 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase7" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase7" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase7/model-fsjq07cp" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.fmu - startTime: 0.000000 - stopTime: 5184000.000000 - tolerance: 0.000001 - stepSize: 60.000000 info: maximum step size for 'model.root': 60.000000 info: Result file: Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.VDI6007.TestCase7_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.intGai.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.intGai.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.reference.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.reference.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.setTemp.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_VDI6007_TestCase7.setTemp.tableName will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 360 and h = 60, the corrector convergence test failed repeatedly or with |h| = hmin. error: [doStepCVODE] CVode failed with flag = -4 warning: Bad return code at time 360.000000 error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 6 NumRhsEvals = 11 NumLinSolvSetups = 2 NumNonlinSolvIters = 10 NumNonlinSolvConvFails = 1 NumErrTestFails = 0 info: 3 warnings info: 2 errors