/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.ZoneCapacitanceMultiplier_res.mat --tempDir=temp_Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_ZoneCapacitanceMultiplier_fmu --startTime=0 --stopTime=432000 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_ZoneCapacitanceMultiplier.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.ZoneCapacitanceMultiplier/temp_Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_ZoneCapacitanceMultiplier_fmu/model-bft1x3zs/temp/0001_Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_ZoneCapacitanceMultiplier (logStatusWarning): Returning path (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Examples/SingleFamilyHouse_TwoSpeed_ZoneAirBalance/SingleFamilyHouse_TwoSpeed_ZoneAirBalance_zoneCapacitanceMultiplier.idf) not in the resources directory. The FMU might not work as expected if you send it to a different system LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_ASSERT | debug | Solving non-linear system 131 failed at time=0. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.ZoneCapacitanceMultiplier/temp_Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_ZoneCapacitanceMultiplier_fmu/model-bft1x3zs/temp/0001_Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_ZoneCapacitanceMultiplier (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ThermalZone_ZoneCapacitanceMultiplier" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 1 warnings info: 4 errors