/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Fluid.Movers.Validation.FlowControlled_dpSystem_res.mat --tempDir=temp_Buildings_9_Buildings_Fluid_Movers_Validation_FlowControlled_dpSystem_fmu --startTime=0 --stopTime=1 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Fluid_Movers_Validation_FlowControlled_dpSystem.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floConDp.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((floConDpSystem.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_9_Buildings.Fluid.Movers.Validation.FlowControlled_dpSystem_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo:134:5-139:3:writable] | | | | The following assertion has been violated at time 0.751000 | | | | ((heaCoi1.m_flow > (-floConDp.vol.m_flow_small))) --> "In FlowControlled_dpSystem.floConDp.vol: Model has flow reversal, | | | | but the parameter allowFlowReversal is set to false. | | | | m_flow_small = 0.0001 | | | | ports[1].m_flow = -0.00148812 | | | | " error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.Movers.Validation.FlowControlled_dpSystem/temp_Buildings_9_Buildings_Fluid_Movers_Validation_FlowControlled_dpSystem_fmu/model-nxeeotev/temp/0001_Buildings_9_Buildings_Fluid_Movers_Validation_FlowControlled_dpSystem (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable zone4.use_C_flow info: Final Statistics for 'model.root': NumSteps = 250 NumRhsEvals = 251 NumLinSolvSetups = 14 NumNonlinSolvIters = 250 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 2 errors