/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones1" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones1" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones1/model-nul7e1iv" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Using pre-compiled FMU /tmp/fmi4c_GZK6ue/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones1.fmu LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones1/spawn-FMUZoneAdapterZones1/EnergyPlus.fmu. It will not be converted to SI units. LOG_STDOUT | info | 0.000 FMUZoneAdapterZones1.building: Warning from EnergyPlus: "*** Test warning written by Zones1.core.&##10;" info: maximum step size for 'model.root': 1.440000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones1.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 42 NumRhsEvals = 43 NumLinSolvSetups = 3 NumNonlinSolvIters = 42 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors