Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_11_Buildings.Templates.Plants.HeatPumps.Validation.AirToWater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001908/0.001908, allocations: 107.4 kB / 16.4 MB, free: 6.5 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001996/0.001996, allocations: 192.5 kB / 19.35 MB, free: 3.734 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.478/1.478, allocations: 222.9 MB / 245.1 MB, free: 15.01 MB / 206.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/package.mo): time 2.872/2.872, allocations: 469.8 MB / 0.7491 GB, free: 3 MB / 0.6075 GB " [Timeout remaining time 177] Using package Buildings with version 11.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(Buildings.Templates.Plants.HeatPumps.Validation.AirToWater,fileNamePrefix="Buildings_11_Buildings_Templates_Plants_HeatPumps_Validation_AirToWater",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Templates.Plants.HeatPumps.Validation.AirToWater,fileNamePrefix="Buildings_11_Buildings_Templates_Plants_HeatPumps_Validation_AirToWater",fmuType="me",version="2.0",platforms={"static"}) [Timeout 300] "Notification: Performance of FrontEnd - loaded program: time 0.001994/0.001994, allocations: 63.89 kB / 1.073 GB, free: 144 kB / 0.8731 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8794/0.8814, allocations: 159.1 MB / 1.229 GB, free: 4.82 MB / 0.9356 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Templates/Plants/HeatPumps/Validation/UserProject/Data/AllSystems.mo:9:3-71:57:writable] Warning: Components are deprecated in class. Notification: Performance of NFInst.instantiate(Buildings.Templates.Plants.HeatPumps.Validation.AirToWater): time 3.488/4.369, allocations: 1.481 GB / 2.71 GB, free: 8.793 MB / 1.717 GB Notification: Performance of NFInst.instExpressions: time 2.081/6.451, allocations: 350.6 MB / 3.052 GB, free: 5.711 MB / 1.998 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.08578/6.537, allocations: 2.157 MB / 3.054 GB, free: 5.711 MB / 1.998 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:204:3-209:64:writable] Error: Dimension 1 of 'staEqu' could not be deduced from the component's binding equation 'datAll.pla.ctl.staEqu'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Templates/Plants/HeatPumps/Configuration/HeatPumpPlant.mo:24:3-26:31:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Templates/Plants/HeatPumps/Components/Data/Controller.mo:204:3-209:64:writable] Warning: Parameter datAll.pla.cfg.nHp(fixed = true) has annotation(Evaluate=true) and no binding. [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFTyping.mo:2163:9-2163:91:writable] Error: Internal error NFTyping.typeSubscript got unknown subscript Notification: Performance of FrontEnd: time 0.006258/6.543, allocations: 2.066 MB / 3.056 GB, free: 5.695 MB / 1.998 GB " [Timeout remaining time 293] [Calling sys.exit(0), Time elapsed: 12.462577108992264] Failed to read output from testmodel.py, exit status != 0: 6.54940894106403 6.568720495 -1.0 Calling exit ...