/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Media.Specialized.Air.Examples.PerfectGasDerivativeCheck_res.mat --tempDir=temp_Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck_fmu --startTime=0 --stopTime=1 --timeout=400 --tolerance=1e-08 Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_11_Buildings.Media.Specialized.Air.Examples.PerfectGasDerivativeCheck_res.mat (bufferSize=1) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Specialized/Air/Examples/PerfectGasDerivativeCheck.mo:25:5-25:62:writable] | | | | The following assertion has been violated at time 0.003000 | | | | ((abs(hLiqCod - hLiqSym) < 0.01)) --> "Model has an error" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Media.Specialized.Air.Examples.PerfectGasDerivativeCheck/temp_Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck_fmu/model-5pp2gy8h/temp/0001_Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck (logFmi2Call): fmi2GetReal: terminated by an assertion. error: [updateSignals] failed to fetch variable hSteCod LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Specialized/Air/Examples/PerfectGasDerivativeCheck.mo:25:5-25:62:writable] | | | | The following assertion has been violated at time 0.003000 | | | | ((abs(hLiqCod - hLiqSym) < 0.01)) --> "Model has an error" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Media.Specialized.Air.Examples.PerfectGasDerivativeCheck/temp_Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck_fmu/model-5pp2gy8h/temp/0001_Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Media/Specialized/Air/Examples/PerfectGasDerivativeCheck.mo:25:5-25:62:writable] | | | | The following assertion has been violated at time 0.003000 | | | | ((abs(hLiqCod - hLiqSym) < 0.01)) --> "Model has an error" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Media.Specialized.Air.Examples.PerfectGasDerivativeCheck/temp_Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck_fmu/model-5pp2gy8h/temp/0001_Buildings_11_Buildings_Media_Specialized_Air_Examples_PerfectGasDerivativeCheck (logFmi2Call): fmi2GetReal: terminated by an assertion. error: [updateSignals] failed to fetch variable hSteCod info: Final Statistics for 'model.root': NumSteps = 20 NumRhsEvals = 48 NumLinSolvSetups = 26 NumNonlinSolvIters = 44 NumNonlinSolvConvFails = 0 NumErrTestFails = 12 info: 0 warnings info: 6 errors