/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator_res.mat --tempDir=temp_Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Examples_LargeScaleWaterToWater_OneRoomRadiator_fmu --startTime=0 --stopTime=86400 --timeout=400 --tolerance=1e-08 Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Examples_LargeScaleWaterToWater_OneRoomRadiator.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/HeatPumps/ModularReversible/BaseClasses/CalculateEfficiency.mo:5:3-6:85:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((heaPum.eff.PEleMin >= 1e-15)) --> "Variable violating min constraint: 1e-15 <= heaPum.eff.PEleMin, has value: -1158.29" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Utilities/Math/InverseXRegularized.mo:5:3-5:80:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((heaPum.eff.invXReg.delta >= 0.0)) --> "Variable violating min constraint: 0.0 <= heaPum.eff.invXReg.delta, has value: -1158.29" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaPumSou.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in LargeScaleWaterToWater_OneRoomRadiator.pumHeaPumSou: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:144:3-149:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((7.3838 <= heaPum.refCyc.refCycHeaPumHea.mCon_flow_max)) --> "In LargeScaleWaterToWater_OneRoomRadiator.heaPum.refCyc.refCycHeaPumHea: The nominal condenser mass flow rate (7.3838 kg/s) is bigger than the | | | | maximal value (-0.140152 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:156:3-161:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((7.6823 <= heaPum.refCyc.refCycHeaPumHea.mEva_flow_max)) --> "In LargeScaleWaterToWater_OneRoomRadiator.heaPum.refCyc.refCycHeaPumHea: The nominal evaporator mass flow rate (7.6823 kg/s) is bigger than the | | | | maximal value (-0.125106 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/HeatPumps/ModularReversible/RefrigerantCycle/BaseClasses/PartialTableData2D.mo:138:3-143:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((7.3838 >= heaPum.refCyc.refCycHeaPumCoo.mCon_flow_min)) --> "In LargeScaleWaterToWater_OneRoomRadiator.heaPum.refCyc.refCycHeaPumCoo: The nominal condenser mass flow rate (7.3838 kg/s) is smaller than the | | | | minimal value (9.30435 kg/s) for the table data | | | | when assuming a temperature spread between 3 and 10 K, as in EN 14511." LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/HeatPumps/ModularReversible/BaseClasses/CalculateEfficiency.mo:51:3-54:26:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((heaPum.eff.PEleMin > 0.0)) --> "In LargeScaleWaterToWater_OneRoomRadiator.heaPum.eff: PEleMin must be greater than zero. Disable efficiency calculation using | | | | calEff=false to debug why PEle_nominal is lower than zero." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Fluid.HeatPumps.ModularReversible.Examples.LargeScaleWaterToWater_OneRoomRadiator/temp_Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Examples_LargeScaleWaterToWater_OneRoomRadiator_fmu/model-zxp78oiu/temp/0001_Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Examples_LargeScaleWaterToWater_OneRoomRadiator (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_11_Buildings_Fluid_HeatPumps_ModularReversible_Examples_LargeScaleWaterToWater_OneRoomRadiator" error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 0 warnings info: 4 errors