/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms_res.mat --tempDir=temp_Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.fmu info: model doesn't contain any continuous state LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ala.not10.y)) --> "Warning: fan has been commanded ON but still OFF." info: Result file: Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms_res.mat (bufferSize=1) info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes1.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes2.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes3.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes4.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes5.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes6.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes7.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms.ala.assMes8.message will not be stored in the result file, because the signal type is not supported LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 850.000000 | | | | ((ala.not7.y)) --> "Warning: discharge air temperature is 8 degC less than the setpoint." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 954.547000 | | | | ((ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.ParallelFanVVF.Subsequences.Validation.Alarms/temp_Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms_fmu/model-ni6vh4wd/temp/0001_Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_11_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_ParallelFanVVF_Subsequences_Validation_Alarms"