/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer_res.mat --tempDir=temp_Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer_fmu --startTime=1.87488e+07 --stopTime=1.93536e+07 --stepSize=240.669 --timeout=400 --tolerance=1e-06 Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer/model-cqsvqlzo" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer.fmu - startTime: 18748800.000000 - stopTime: 19353600.000000 - tolerance: 0.000001 - stepSize: 240.669000 LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_ASSERT | debug | Failed to find spawn executable in Buildings Library installation, on SPAWNPATH and on PATH. See installation instructions at Buildings.ThermalZones.EnergyPlus_9_6_0.UsersGuide.Installation LOG_ASSERT | debug | Solving non-linear system 139 failed at time=18748800. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer/model-cqsvqlzo/temp/0001_Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer/logFmi2Call: fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors