/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2_fmu --startTime=0 --stopTime=3600 --timeout=400 --tolerance=1e-06 Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Using pre-compiled FMU /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/temp_Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2_fmu/model-zqg5tfda/temp/0001_Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones3.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/spawn-FMUZoneAdapterZones2/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones2.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
info: maximum step size for 'model.root': 0.001000
info: Result file: model_res.mat (bufferSize=10)
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.epwName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.idfName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonCor.zoneName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.epwName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.fmuName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.idfName will not be stored in the result file, because the signal type is not supported
info: Variable model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2.fmuZonSou.zoneName will not be stored in the result file, because the signal type is not supported
LOG_STDOUT | info | 60.001 FMUZoneAdapterZones2.building: Error from EnergyPlus: Current time 6.0001000000000005E+01 is after next time event 6.0000000000000000E+01. Consider to change option 2.2204460492503131E-14.
LOG_ASSERT | debug | 60.001 FMUZoneAdapterZones2.fmuZonCor: Failed to enter event mode in SpawnUtil.c, returned status is Error.
error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones2/temp_Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2_fmu/model-zqg5tfda/temp/0001_Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2 (logFmi2Call): internalEventUpdate: terminated by an assertion.
error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Buildings_10_Buildings_ThermalZones_EnergyPlus_9_6_0_BaseClasses_Validation_FMUZoneAdapterZones2"
error: [operator()] Timeout occurred during simulation
info: 0 warnings
info: 3 errors
info: Final Statistics for 'model.root':
NumSteps = 1368048 NumRhsEvals = 1368049 NumLinSolvSetups = 68404
NumNonlinSolvIters = 1368048 NumNonlinSolvConvFails = 0 NumErrTestFails = 0
[CVODE ERROR] CVode
cvode_mem = NULL illegal.
error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21