/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_10_Buildings.Experimental.DHC.Loads.Steam.Examples.BuildingTimeSeriesAtETS_res.mat --tempDir=temp_Buildings_10_Buildings_Experimental_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS_fmu --startTime=1.728e+06 --stopTime=1.8144e+06 --stepSize=34.56 --timeout=400 --tolerance=1e-06 Buildings_10_Buildings_Experimental_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Loads.Steam.Examples.BuildingTimeSeriesAtETS" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Loads.Steam.Examples.BuildingTimeSeriesAtETS" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork_2/OpenModelicaLibraryTesting/Buildings_10_Buildings.Experimental.DHC.Loads.Steam.Examples.BuildingTimeSeriesAtETS/model-8whq5bze" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_10_Buildings_Experimental_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS.fmu - startTime: 1728000.000000 - stopTime: 1814400.000000 - tolerance: 0.000001 - stepSize: 34.560000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 1728000.000000 | | | | ((not (bui.pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or bui.pumCNR.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in BuildingTimeSeriesAtETS.bui.pumCNR: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 1728000.000000 | | | | ((bui.pumCNR.per.haveWMot_nominal or not (bui.pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or bui.pumCNR.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in BuildingTimeSeriesAtETS.bui.pumCNR: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Media/Steam.mo:26:5-26:42:writable] | | | | The following assertion has been violated at time 1728000.000000 | | | | ((bui.sta_a.T >= 1.0 and bui.sta_a.T <= 1e4)) --> "Variable violating min/max constraint: 1.0 <= bui.sta_a.T <= 1e4, has value: -906.886" info: maximum step size for 'model.root': 34.560000 info: Result file: Buildings_10_Buildings.Experimental.DHC.Loads.Steam.Examples.BuildingTimeSeriesAtETS_res.mat (bufferSize=1) info: Variable model.root.Buildings_10_Buildings_Experimental_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS.bui.QHea.fileName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_10_Buildings_Experimental_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS.bui.QHea.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_10_Buildings_Experimental_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS.bui.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_10_Buildings_Experimental_DHC_Loads_Steam_Examples_BuildingTimeSeriesAtETS.bui.tableName will not be stored in the result file, because the signal type is not supported [CVODE ERROR] CVode At t = 1.728e+06 and h = 34.56, the corrector convergence test failed repeatedly or with |h| = hmin. error: [doStepCVODE] CVode failed with flag = -4 warning: Bad return code at time 1728000.000000 error: [SimulateSingleFMU] oms_simulate failed info: Final Statistics for 'model.root': NumSteps = 0 NumRhsEvals = 6 NumLinSolvSetups = 1 NumNonlinSolvIters = 5 NumNonlinSolvConvFails = 1 NumErrTestFails = 0 info: 3 warnings info: 2 errors