/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6_fmu --startTime=0 --stopTime=1000 --timeout=50 --tolerance=1e-06 BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((valHea.m_flow >= 0.0 and valHea.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= valHea.m_flow <= 1e5, has value: -1.03825e-20" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((tabsSouth1[4].m_flow >= 0.0 and tabsSouth1[4].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= tabsSouth1[4].m_flow <= 1e5, has value: -1.62706e-29" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Examples.FlowSystem.Simplified6/temp_BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6_fmu/model-t3guz6oc/temp/0001_BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6 (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Examples.FlowSystem.Simplified6/temp_BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6_fmu/model-t3guz6oc/temp/0001_BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildingSystems_BuildingSystems.Fluid.Examples.FlowSystem.Simplified6/temp_BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6_fmu/model-t3guz6oc/temp/0001_BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6 (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.BuildingSystems_BuildingSystems_Fluid_Examples_FlowSystem_Simplified6"