/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_HeatExchangers_Examples_WaterCooler_T_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-08 BuildSysPro_BuildSysPro_IBPSA_Fluid_HeatExchangers_Examples_WaterCooler_T.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0-master/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (mov.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in WaterCooler_T.mov: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0-master/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((mov.per.haveWMot_nominal or not (mov.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in WaterCooler_T.mov: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatExchangers.Examples.WaterCooler_T/temp_BuildSysPro_BuildSysPro_IBPSA_Fluid_HeatExchangers_Examples_WaterCooler_T_fmu/model-irnf8jax/temp/0001_BuildSysPro_BuildSysPro_IBPSA_Fluid_HeatExchangers_Examples_WaterCooler_T (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.BuildSysPro_BuildSysPro_IBPSA_Fluid_HeatExchangers_Examples_WaterCooler_T"