/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu --startTime=0 --stopTime=172800 --timeout=50 --tolerance=1e-05 AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation1.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.4.0-development/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((substation2.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | debug | New end position is not bigger then previous last node. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage/temp_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu/model-oeg65mdw/temp/0001_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage" LOG_ASSERT | debug | New end position is not bigger then previous last node. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_latest_AixLib.Fluid.DistrictHeatingCooling.Supplies.Examples.DHCSupplyHeaterCoolerStorage/temp_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage_fmu/model-oeg65mdw/temp/0001_AixLib_latest_AixLib_Fluid_DistrictHeatingCooling_Supplies_Examples_DHCSupplyHeaterCoolerStorage (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable substation2.vol1.use_C_flow info: Final Statistics for 'model.root': NumSteps = 31362 NumRhsEvals = 31363 NumLinSolvSetups = 1570 NumNonlinSolvIters = 31362 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 4 errors