/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_fmu --startTime=0 --stopTime=604800 --timeout=50 --tolerance=1e-06 AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.intGai.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.intGai.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.outdoorTemp.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.outdoorTemp.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.reference.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.reference.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.senMasFra.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.tableSolRadWindow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.tableSolRadWindow.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.ventRate.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain.ventRate.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.ThermalZones.ReducedOrder.Validation.RoomWithoutLatentGain/temp_AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain_fmu/model-jc232u0k/temp/0001_AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_terminated state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.AixLib_AixLib_ThermalZones_ReducedOrder_Validation_RoomWithoutLatentGain"