/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Example_ThrottlePump_fmu --startTime=0 --stopTime=600 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Systems_HydraulicModules_Example_ThrottlePump.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eta, has value: -8.76995e-44" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.heaDis.etaHyd, has value: -7.35443e-41" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ThrottlePump.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= ThrottlePump.PumpInterface.pump.eff.yMot, has value: -9.78277e-46" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_ThrottlePump.ThrottlePump.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_ThrottlePump.ThrottlePump.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_ThrottlePump.ThrottlePump.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_ThrottlePump.ThrottlePump.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_ThrottlePump.ThrottlePump.pipeModel will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors