/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Systems_HydraulicModules_Example_Pump_fmu --startTime=0 --stopTime=800 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Systems_HydraulicModules_Example_Pump.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Unmixed.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.eta, has value: -1.57728e-31" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Unmixed.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.heaDis.etaHyd, has value: -1.3227e-28" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.0/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Unmixed.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= Unmixed.PumpInterface.pump.eff.yMot, has value: -1.75944e-33" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Pump.Unmixed.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Pump.Unmixed.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Pump.Unmixed.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Pump.Unmixed.pipeModel will not be stored in the result file, because the signal type is not supported LOG_ASSERT | debug | New end position is not bigger then previous last node. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Pump/temp_AixLib_AixLib_Systems_HydraulicModules_Example_Pump_fmu/model-zwide6a7/temp/0001_AixLib_AixLib_Systems_HydraulicModules_Example_Pump (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.AixLib_AixLib_Systems_HydraulicModules_Example_Pump" LOG_ASSERT | debug | New end position is not bigger then previous last node. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.HydraulicModules.Example.Pump/temp_AixLib_AixLib_Systems_HydraulicModules_Example_Pump_fmu/model-zwide6a7/temp/0001_AixLib_AixLib_Systems_HydraulicModules_Example_Pump (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable pumpOn.y info: Final Statistics for 'model.root': NumSteps = 2 NumRhsEvals = 3 NumLinSolvSetups = 2 NumNonlinSolvIters = 2 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 0 warnings info: 4 errors